Determination of total content and isotopic compositions of plutonium and uranium in environmental samples for safeguards purposes by ICP-QMS

被引:29
|
作者
Duarte Pinto Godoy, Maria Luiza [1 ]
Godoy, Jose Marcus [1 ,2 ]
Roldao, Luiz Alfredo [1 ]
Tauhata, Luiz [1 ]
机构
[1] Inst Radioprotecao & Dosimetria, BR-22642970 Rio De Janeiro, Brazil
[2] Pontificia Univ Catolica Rio de Janeiro, Dept Quim, BR-22453900 Rio De Janeiro, Brazil
关键词
ICP-MS; Safeguards; Plutonium; Uranium; Isotope dilution; Isotopic ratio; Environmental samples; PLASMA-MASS SPECTROMETRY; EXTRACTION CHROMATOGRAPHY; RATIO MEASUREMENTS; ANION-EXCHANGE; NATURAL-WATER; MS; SEPARATION; THORIUM; PRECONCENTRATION; SEDIMENTS;
D O I
10.1016/j.jenvrad.2009.04.012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this work was to determine the concentrations and isotopic compositions of plutonium and uranium in environmental samples for safeguards purposes. An analytical method was developed with a plutonium and uranium separation procedure based on extraction chromatography (using 2 mL TEVA and UTEVA columns) and detection with a quadrupole ICP-MS applying an ultra-sonic nebulizer coupled with a membrane desolvation system. Starting from blank swipes, the background equivalent concentration (BEC) was 8 fg for Pu-239 and 1 ng U-238. The method was successfully applied to certified reference materials as well as to round robin samples obtained in the framework of the inter-laboratory exercise program, promoted by the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC), together with the US Department of Energy (USDOE). After the introduction of an additional ion-exchange separation step, the methodology was applied to the IAEA-384 sediment reference sample with precise and accurate total plutonium and uranium, Pu-240/Pu-239, Pu-241/Pu-239, U-234/U-238 and U-231/U-238 atomic ratio results. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:613 / 625
页数:13
相关论文
共 50 条
  • [1] Application of ICP-QMS for the determination of plutonium in environmental samples for safeguards purposes
    Godoy, Maria Luiza D. P.
    Godoy, Jose Marcus
    Roldao, Luiz Alfredo
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2007, 97 (2-3) : 124 - 136
  • [2] Determination of iodine 129 by ICP-QMS in environmental samples
    Bienvenu, P
    Brochard, E
    Excoffier, E
    Piccione, M
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2004, 49 (06): : 423 - 428
  • [3] Determination of uranium by means of ICP-QMS
    Lamas, M
    Fleckenstein, J
    Schroetter, S
    Sparovek, RM
    Schnug, E
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2002, 33 (15-18) : 3469 - 3479
  • [4] Determination of selenium in biological samples using ICP-QMS
    Boulyga, S
    Dombovári, J
    Becker, JS
    Dietze, HJ
    ATOMIC SPECTROSCOPY, 2000, 21 (05) : 149 - 155
  • [5] Space charge and mass discrimination effects on lead isotope ratio measurements by ICP-QMS in environmental samples with high uranium content
    Santos, Rui
    Machado, M. J. Canto
    Ruiz, Izabel
    Sato, Kei
    Vasconcelos, M. T. S. D.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (07) : 783 - 790
  • [6] Analysis of IAEA environmental samples for plutonium and uranium by ICP/MS in support of international safeguards
    Farmer, O. T., III
    Olsen, K. B.
    Thomas, M. L.
    Garofoli, S. J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (02) : 489 - 492
  • [7] Analysis of IAEA environmental samples for plutonium and uranium by ICP/MS in support of international safeguards
    O. T. Farmer
    K. B. Olsen
    M. L. Thomas
    S. J. Garofoli
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 489 - 492
  • [8] Development and validation of an analytical method for the determination of lead isotopic composition using ICP-QMS
    Rodriguez-Salazar, M. T.
    Morton Bermea, O.
    Hernandez-Alvarez, E.
    Garcia-Arreola, M. E.
    Ortuno-Arzate, M. T.
    GEOFISICA INTERNACIONAL, 2010, 49 (03): : 113 - 117
  • [9] Overcoming ICP-QMS instrumental limitations for 99Tc determination in environmental solid samples using radiochemistry
    Mas, JL
    García-León, M
    Bolívar, JP
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (04) : 502 - 507