Measurements of 25-Hydroxyvitamin D Concentrations in Archived Dried Blood Spots Are Reliable and Accurately Reflect Those in Plasma

被引:56
|
作者
Heath, Alicia K. [1 ,2 ]
Williamson, Elizabeth J. [1 ,2 ,3 ]
Ebeling, Peter R. [4 ]
Kvaskoff, David [5 ]
Eyles, Darryl W. [5 ,6 ]
English, Dallas R. [1 ,2 ]
机构
[1] Univ Melbourne, Ctr Biostat & Epidemiol, Melbourne Sch Populat & Global Hlth, Melbourne, Vic 3010, Australia
[2] Canc Council Victoria, Canc Epidemiol Ctr, Melbourne, Vic 3004, Australia
[3] Monash Univ, Dept Epidemiol & Prevent Med, Melbourne, Vic 3004, Australia
[4] Univ Melbourne, Northwest Acad Ctr, St Albans, Vic 3021, Australia
[5] Univ Queensland, Queensland Brain Inst, St Lucia, Qld 4072, Australia
[6] Pk Ctr Mental Hlth, Queensland Ctr Mental Hlth Res, Wacol, Qld 4076, Australia
基金
英国医学研究理事会;
关键词
VITAMIN-D; RISK;
D O I
10.1210/jc.2014-1269
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context: Recognition that vitamin D might be associated with many chronic diseases has led to large-scale epidemiological and clinical studies. Dried blood spots (DBS) are a useful resource for these studies. Consequently, accurate, efficient, and inexpensive assays to quantify 25-hydroxyvitamin D (25OHD) in DBS are required. Objective: This study evaluated the validity and reliability of a liquid chromatography-tandem mass spectrometry assay for measuring 25OHD in archived DBS and compared measurements of 25OHD in DBS with those in plasma. Design and Participants: Sixty-two participants in the Melbourne Collaborative Cohort Study who had plasma and matching DBS stored since study entry in the early 1990s were randomly selected for a study calibrating 25OHD concentrations in DBS with plasma. As part of a study of vitamin D and mortality, cancer, and diabetes, we also assessed the reliability of measurements from DBS using 500 replicates placed randomly within 31 batches run over 15 months. Outcome Measure: 25OHD concentrations were measured by liquid chromatography-tandem mass spectrometry. Results: There was good agreement between measurements of 25OHD from DBS and plasma; R-2 = 0.73 from a regression of plasma concentration on DBS concentration. The within-batch and between-batch intraclass correlations from the 500 replicate measurements were 0.82 (95% confidence interval, 0.80, 0.85) and 0.73 (95% confidence interval, 0.68, 0.78), respectively. Conclusions: Measuring 25OHD in DBS is a valid and reliable alternative to measuring 25OHD in sera or plasma. A simple calibration model was developed to convert measurements from DBS to equivalent plasma measurements, thus enabling comparisons against clinical reference ranges and with studies using sera or plasma samples.
引用
收藏
页码:3319 / 3324
页数:6
相关论文
共 50 条
  • [1] Comparison of 25-hydroxyvitamin D concentration in chimpanzee dried blood spots and serum
    Moittie, Sophie
    Graham, Peter A.
    Barlow, Nicola
    Dobbs, Phillipa
    Liptovszky, Matyas
    Redrobe, Sharon
    White, Kate
    VETERINARY CLINICAL PATHOLOGY, 2020, 49 (02) : 299 - 306
  • [2] Genetic correlates of vitamin D-binding protein and 25-hydroxyvitamin D in neonatal dried blood spots
    Albinana, Clara
    Zhu, Zhihong
    Borbye-Lorenzen, Nis
    Boelt, Sanne Grundvad
    Cohen, Arieh S.
    Skogstrand, Kristin
    Wray, Naomi R.
    Revez, Joana A.
    Prive, Florian
    Petersen, Liselotte V.
    Bulik, Cynthia M.
    Plana-Ripoll, Oleguer
    Musliner, Katherine L.
    Agerbo, Esben
    Borglum, Anders D.
    Hougaard, David M.
    Nordentoft, Merete
    Werge, Thomas
    Mortensen, Preben Bo
    Vilhjalmsson, Bjarni J.
    McGrath, John J.
    NATURE COMMUNICATIONS, 2023, 14 (01)
  • [3] Simplified 25-Hydroxyvitamin D Standardization and Optimization in Dried Blood Spots by LC-MS/MS
    Makowski, Andrew J.
    Rathmacher, John A.
    Horst, Ronald L.
    Sempos, Christopher T.
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (05) : 1328 - 1336
  • [4] Environmental and individual predictors of 25-hydroxyvitamin D concentrations in Denmark measured from neonatal dried blood spots: the D-tect study
    Keller, Amelie
    Frederiksen, Peder
    Handel, Mina N.
    Jacobsen, Ramune
    McGrath, John J.
    Cohen, Arieh S.
    Heitmann, Berit L.
    BRITISH JOURNAL OF NUTRITION, 2019, 121 (05) : 567 - 575
  • [5] Importance of C-3 epimer of 25-hydroxyvitamin D in dried blood spots of neonatal population
    Tapan, Serkan
    Sertoglu, Erdim
    Uyanik, Metin
    INTERNATIONAL JOURNAL OF CANCER, 2015, 137 (03) : 750 - 750
  • [6] Evaluation of the Analytical and Clinical Concordance of 25-Hydroxyvitamin D Levels in Dried Blood Spots, Dried Serum Spots, and Serum as Potential Biorepository Specimens
    Karvaly, Gellert
    Molnar-Vilagos, Gyorgyi
    Kovacs, Krisztian
    Meszaros, Katalin
    Patocs, Attila
    Vasarhelyi, Barna
    BIOPRESERVATION AND BIOBANKING, 2017, 15 (04) : 285 - 292
  • [7] Response to "importance of C-3 epimer of 25-hydroxyvitamin D in dried blood spots of neonatal population"
    Bhatti, Parveen
    Doody, David R.
    Mckean-Cowdin, Roberta
    Mueller, Beth A.
    INTERNATIONAL JOURNAL OF CANCER, 2015, 137 (03) : 751 - 751
  • [8] Analytical Bias in the Measurement of Plasma 25-Hydroxyvitamin D Concentrations in Infants
    Rueter, Kristina
    Black, Lucinda J.
    Jones, Anderson
    Bulsara, Max
    Clarke, Michael W.
    Gamez, Cristina
    Lim, Ee M.
    Palmer, Debra J.
    Prescott, Susan L.
    Siafarikas, Aris
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (02)
  • [9] Plasma 25-Hydroxyvitamin D Concentrations and Periodontal Disease in Postmenopausal Women
    Millen, Amy E.
    Hovey, Kathleen M.
    LaMonte, Michael J.
    Swanson, Mya
    Andrews, Christopher A.
    Kluczynski, Melissa A.
    Genco, Robert J.
    Wactawski-Wende, Jean
    JOURNAL OF PERIODONTOLOGY, 2013, 84 (09) : 1243 - 1256
  • [10] Minimizing Matrix Effects for the Accurate Quantification of 25-Hydroxyvitamin D Metabolites in Dried Blood Spots by LC-MS/MS
    Kvaskoff, David
    Heath, Alicia K.
    Simila, Henry A.
    Ko, Pauline
    English, Dallas R.
    Eyles, Darryl W.
    CLINICAL CHEMISTRY, 2016, 62 (04) : 639 - 646