Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations

被引:98
|
作者
Flampouri, Stella
Jiang, Steve B.
Sharp, Greg C.
Wolfgang, John
Patel, Abhijit A.
Choi, Noah C.
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 11期
关键词
D O I
10.1088/0031-9155/51/11/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to accurately estimate the difference between the planned and the delivered dose due to respiratory motion and free breathing helical CT artefacts for lung IMRT treatments, and to estimate the impact of this difference on clinical outcome. Six patients with representative tumour motion, size and position were selected for this retrospective study. For each patient, we had acquired both a free breathing helical CT and a ten-phase 4D-CT scan. A commercial treatment planning system was used to create four IMRT plans for each patient. The first two plans were based on the GTV as contoured on the free breathing helical CT set, with a GTV to PTV expansion of 1.5 cm and 2.0 cm, respectively. The third plan was based on the ITV, a composite volume formed by the union of the CTV volumes contoured on free breathing helical CT, end-of-inhale (EOI) and end-of-exhale (EOE) 4D-CT. The fourth plan was based on GTV contoured on the EOE 4D-CT. The prescribed dose was 60 Gy for all four plans. Fluence maps and beam setup parameters of the IMRT plans were used by the Monte Carlo dose calculation engine MCSIM for absolute dose calculation on both the free breathing CT and 4D-CT data. CT deformable registration between the breathing phases was performed to estimate the motion trajectory for both the tumour and healthy tissue. Then, a composite dose distribution over the whole breathing cycle was calculated as a final estimate of the delivered dose. EUD values were computed on the basis of the composite dose for all four plans. For the patient with the largest motion effect, the difference in the EUD of CTV between the planed and the delivered doses was 33, 11, 1 and 0 Gy for the first, second, third and fourth plan, respectively. The number of breathing phases required for accurate dose prediction was also investigated. With the advent of 4D-CT, deformable registration and Monte Carlo simulations, it is feasible to perform an accurate calculation of the delivered dose, and compare our delivered dose with doses estimated using prior techniques.
引用
收藏
页码:2763 / 2779
页数:17
相关论文
共 50 条
  • [41] Variational Optical Flow Estimation Based Super-Resolution Reconstruction for Lung 4D-CT Image
    Geng F.
    Liu H.
    Guo Q.
    Yin Y.
    Jisuanji Yanjiu yu Fazhan/Computer Research and Development, 2017, 54 (08): : 1703 - 1712
  • [42] Adaptive patch-based POCS approach for super resolution reconstruction of 4D-CT lung data
    Wang, Tingting
    Cao, Lei
    Yang, Wei
    Feng, Qianjin
    Chen, Wufan
    Zhang, Yu
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 5939 - 5954
  • [43] Accumulated treatment dose for image guided liver radiotherapy using deformable registration of 4D cone beam CT
    Velec, M.
    Moseley, J.
    Dawson, L. A.
    Brock, K. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S149 - S149
  • [44] Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume
    Admiraal, Marjan A.
    Schuring, Danny
    Hurkmans, Coen W.
    RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) : 55 - 60
  • [45] Accumulation of the delivered dose based on cone-beam CT and deformable image registration for non-small cell lung cancer treated with hypofractionated radiotherapy
    Wang, Bin
    Wang, Da Quan
    Lin, Mao Sheng
    Lu, Shi Pei
    Zhang, Jun
    Chen, Li
    Li, Qi Wen
    Cheng, Zhang Kai
    Liu, Fang Jie
    Guo, Jin Yu
    Liu, Hui
    Qiu, Bo
    BMC CANCER, 2020, 20 (01)
  • [46] Accumulation of the delivered dose based on cone-beam CT and deformable image registration for non-small cell lung cancer treated with hypofractionated radiotherapy
    Bin Wang
    Da Quan Wang
    Mao Sheng Lin
    Shi Pei Lu
    Jun Zhang
    Li Chen
    Qi Wen Li
    Zhang Kai Cheng
    Fang Jie Liu
    Jin Yu Guo
    Hui Liu
    Bo Qiu
    BMC Cancer, 20
  • [47] Feasibility of using single photon counting X-ray for lung tumor position estimation based on 4D-CT
    Aschenbrenner, Katharina P.
    Guthier, Christian V.
    Lyatskaya, Yulia
    Boda-Heggemann, Judit
    Wenz, Frederik
    Hesser, Juergen W.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (03): : 243 - 254
  • [48] Lung Tumor Motion Tracking Using Sequential Interphase Deformable Registration in 4D CT Images for Radiation Treatment Planning
    Jung, J.
    Jo, H.
    Hong, H.
    Kang, Y.
    Lee, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S668 - S669
  • [49] Lung Respiratory Motion Estimation Based on Fast Kalman Filtering and 4D CT Image Registration
    Xue, Peng
    Fu, Yu
    Ji, Huizhong
    Cui, Wentao
    Dong, Enqing
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (06) : 2007 - 2017
  • [50] A Phantom-Based Comparison of Lung Tumor Planning Target Volumes and Organs a Risk Dose Reduction Between 4D-CT and 3D-CT
    Zehtabian, M.
    Faghihi, R.
    Mosleh-Shirazi, M.
    Shepherd, J.
    Mohammadi, M.
    Sarasanandarajah, S.
    Higgs, B.
    MEDICAL PHYSICS, 2013, 40 (06)