Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations

被引:98
|
作者
Flampouri, Stella
Jiang, Steve B.
Sharp, Greg C.
Wolfgang, John
Patel, Abhijit A.
Choi, Noah C.
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 11期
关键词
D O I
10.1088/0031-9155/51/11/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to accurately estimate the difference between the planned and the delivered dose due to respiratory motion and free breathing helical CT artefacts for lung IMRT treatments, and to estimate the impact of this difference on clinical outcome. Six patients with representative tumour motion, size and position were selected for this retrospective study. For each patient, we had acquired both a free breathing helical CT and a ten-phase 4D-CT scan. A commercial treatment planning system was used to create four IMRT plans for each patient. The first two plans were based on the GTV as contoured on the free breathing helical CT set, with a GTV to PTV expansion of 1.5 cm and 2.0 cm, respectively. The third plan was based on the ITV, a composite volume formed by the union of the CTV volumes contoured on free breathing helical CT, end-of-inhale (EOI) and end-of-exhale (EOE) 4D-CT. The fourth plan was based on GTV contoured on the EOE 4D-CT. The prescribed dose was 60 Gy for all four plans. Fluence maps and beam setup parameters of the IMRT plans were used by the Monte Carlo dose calculation engine MCSIM for absolute dose calculation on both the free breathing CT and 4D-CT data. CT deformable registration between the breathing phases was performed to estimate the motion trajectory for both the tumour and healthy tissue. Then, a composite dose distribution over the whole breathing cycle was calculated as a final estimate of the delivered dose. EUD values were computed on the basis of the composite dose for all four plans. For the patient with the largest motion effect, the difference in the EUD of CTV between the planed and the delivered doses was 33, 11, 1 and 0 Gy for the first, second, third and fourth plan, respectively. The number of breathing phases required for accurate dose prediction was also investigated. With the advent of 4D-CT, deformable registration and Monte Carlo simulations, it is feasible to perform an accurate calculation of the delivered dose, and compare our delivered dose with doses estimated using prior techniques.
引用
收藏
页码:2763 / 2779
页数:17
相关论文
共 50 条
  • [21] Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
    Mohammadi, Gh. R. Fallah
    Alam, N. Riyahi
    Geraily, Gh.
    Paydar, R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (04): : 313 - 321
  • [22] Validation of 4D Monte Carlo dose calculations using a programmable deformable lung phantom
    Gholampourkashi, Sara
    Cygler, Joanna E.
    Lavigne, Bernie
    Heath, Emily
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 16 - 27
  • [23] Application of Virtual Patient Model in 4D IMRT Monte Carlo Treatment Planning
    He, W.
    Guo, B.
    Xu, X.
    Shi, C.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [24] A Monte Carlo-based tool for proton dose verification on patient CT data
    Szymanowski, H
    Nill, S
    Oelfke, U
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S319 - S319
  • [25] Personalized 3D Dose Prediction for Intrabeam Treatments Based On Patient CT Imaging with Monte Carlo GATE Simulations
    Bouzid, D.
    Nicolas, B.
    Dupre, P.
    Bert, J.
    Pradier, O.
    Visvikis, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [26] On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations
    Perisinakis, Kostas
    Tzedakis, Antonis
    Damilakis, John
    MEDICAL PHYSICS, 2008, 35 (05) : 2018 - 2028
  • [27] Adaptation of GEANT4 to Monte Carlo dose calculations based on CT data
    Jiang, H
    Paganetti, H
    MEDICAL PHYSICS, 2004, 31 (10) : 2811 - 2818
  • [28] IMRT treatment plans and functional planning with functional lung imaging from 4D-CT for thoracic cancer patients
    Tzung-Chi Huang
    Chien-Yi Hsiao
    Chun-Ru Chien
    Ji-An Liang
    Tzu-Ching Shih
    Geoffrey G Zhang
    Radiation Oncology, 8
  • [29] 4D-CT and PET based treatment planning for fractionated stereotactic lung radiosurgery
    Jin, J
    Ajlouni, M
    Chen, Q
    Yin, F
    Movsas, B
    LUNG CANCER, 2005, 49 : S309 - S309
  • [30] IMRT treatment plans and functional planning with functional lung imaging from 4D-CT for thoracic cancer patients
    Huang, Tzung-Chi
    Hsiao, Chien-Yi
    Chien, Chun-Ru
    Liang, Ji-An
    Shih, Tzu-Ching
    Zhang, Geoffrey G.
    RADIATION ONCOLOGY, 2013, 8