Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations

被引:98
|
作者
Flampouri, Stella
Jiang, Steve B.
Sharp, Greg C.
Wolfgang, John
Patel, Abhijit A.
Choi, Noah C.
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 11期
关键词
D O I
10.1088/0031-9155/51/11/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to accurately estimate the difference between the planned and the delivered dose due to respiratory motion and free breathing helical CT artefacts for lung IMRT treatments, and to estimate the impact of this difference on clinical outcome. Six patients with representative tumour motion, size and position were selected for this retrospective study. For each patient, we had acquired both a free breathing helical CT and a ten-phase 4D-CT scan. A commercial treatment planning system was used to create four IMRT plans for each patient. The first two plans were based on the GTV as contoured on the free breathing helical CT set, with a GTV to PTV expansion of 1.5 cm and 2.0 cm, respectively. The third plan was based on the ITV, a composite volume formed by the union of the CTV volumes contoured on free breathing helical CT, end-of-inhale (EOI) and end-of-exhale (EOE) 4D-CT. The fourth plan was based on GTV contoured on the EOE 4D-CT. The prescribed dose was 60 Gy for all four plans. Fluence maps and beam setup parameters of the IMRT plans were used by the Monte Carlo dose calculation engine MCSIM for absolute dose calculation on both the free breathing CT and 4D-CT data. CT deformable registration between the breathing phases was performed to estimate the motion trajectory for both the tumour and healthy tissue. Then, a composite dose distribution over the whole breathing cycle was calculated as a final estimate of the delivered dose. EUD values were computed on the basis of the composite dose for all four plans. For the patient with the largest motion effect, the difference in the EUD of CTV between the planed and the delivered doses was 33, 11, 1 and 0 Gy for the first, second, third and fourth plan, respectively. The number of breathing phases required for accurate dose prediction was also investigated. With the advent of 4D-CT, deformable registration and Monte Carlo simulations, it is feasible to perform an accurate calculation of the delivered dose, and compare our delivered dose with doses estimated using prior techniques.
引用
收藏
页码:2763 / 2779
页数:17
相关论文
共 50 条
  • [1] Investigation of the actually delivered patient dose in lung BIRT treatment based on deformable registration of 4D CT data and Monte Carlo simulations
    Flampouri, S
    Sharp, G
    Wolfgang, J
    Niemierko, A
    Choi, N
    Jiang, S
    MEDICAL PHYSICS, 2005, 32 (06) : 2095 - 2095
  • [2] 4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis
    Boldea, Vlad
    Sharp, Gregory C.
    Jiang, Steve B.
    Sarrut, David
    MEDICAL PHYSICS, 2008, 35 (03) : 1008 - 1018
  • [3] Evaluation of the Effects of Dose on Lung Ventilation Calculated from 4D-CT using Deformable Image Registration An Application of a Ventilation Calculation Algorithm based on 4D-CT
    Latifi, Kujtim
    Dilling, Thomas J.
    Stevens, Craig W.
    Feygelman, Vladimir
    Moros, Eduardo G.
    Zhang, Geoffrey G.
    BIOIMAGING: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOIMAGING, 2014, : 5 - 11
  • [4] LungRegNet: An unsupervised deformable image registration method for 4D-CT lung
    Fu, Yabo
    Lei, Yang
    Wang, Tonghe
    Higgins, Kristin
    Bradley, Jeffrey D.
    Curran, Walter J.
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL PHYSICS, 2020, 47 (04) : 1763 - 1774
  • [5] Deformable registration of 4D-CT lung image using landmark tracking
    Wu, Junha
    Hu, Bingfeng
    Yang, Xuan
    BIOMEDICAL RESEARCH-INDIA, 2016, 27 (03): : 801 - 811
  • [6] Effects of Noise in 4D-CT On Deformable Image Registration and Derived Ventilation Data
    Latifi, K.
    Huang, T.
    Feygelman, V.
    Budzevich, M.
    Stevens, C.
    Dilling, T.
    Moros, E.
    Van Elmpt, W.
    Dekker, A.
    Zhang, G.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Use of 4D-CT and Deformable Registration to Determine the Impact of Respiratory Motion on Lung Dose from Radiation Therapy
    Li, J.
    Chan, M. F.
    Hu, Y.
    Schupak, K.
    Burman, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S708 - S708
  • [8] Monte Carlo Based IMRT Dose Verification Using Measured Fluence Distributions and Patient CT Data
    Jacobs, J.
    Luo, W.
    MEDICAL PHYSICS, 2018, 45 (06) : E164 - E164
  • [9] A Preliminary Study on Convolutional Neural Networks for 4D-CT Lung Deformable Image Registration
    Fu, Y.
    Li, H.
    Yang, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E564 - E564
  • [10] Effects of quantum noise in 4D-CT on deformable image registration and derived ventilation data
    Latifi, Kujtim
    Huang, Tzung-Chi
    Feygelman, Vladimir
    Budzevich, Mikalai M.
    Moros, Eduardo G.
    Dilling, Thomas J.
    Stevens, Craig W.
    van Elmpt, Wouter
    Dekker, Andre
    Zhang, Geoffrey G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : 7661 - 7672