Comparison of Blood Flow Velocity Quantification by 4D Flow MR Imaging with Ultrasound at the Carotid Bifurcation

被引:70
作者
Harloff, A. [1 ]
Zech, T. [1 ]
Wegent, F. [1 ]
Strecker, C. [1 ]
Weiller, C. [1 ]
Markl, M. [2 ,3 ]
机构
[1] Univ Hosp Freiburg, Dept Neurol, D-79106 Freiburg, Germany
[2] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, Chicago, IL 60611 USA
关键词
PHASE-CONTRAST MRI; SENSITIVE 4-DIMENSIONAL MRI; MAGNETIC-RESONANCE; CEREBRAL-ARTERIES; STENOSIS; ANGIOGRAPHY; REPRODUCIBILITY; VISUALIZATION; HEMODYNAMICS; 2D;
D O I
10.3174/ajnr.A3419
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: 4D flow MR imaging is an emerging technique that allows visualization and quantification of 3D blood flow in vivo. However, representative studies evaluating its accuracy are lacking. Therefore, we compared blood flow quantification by using 4D flow MR imaging with US within the carotid bifurcation. MATERIALS AND METHODS: Thirty-two healthy volunteers (age 25.3 3.4 years) and 20 patients with 50% ICA stenosis (age 67.7 7.4 years) were examined preoperatively and postoperatively by use of 4D flow MR imaging, with complete coverage of the left and right carotid bifurcation. Blood flow velocities were assessed with standardized 2D analysis planes distributed along the CCA and the ICA and were compared with US at baseline and postoperatively in patients. In addition, we tested reproducibility and interobserver agreement of 4D MR imaging in 10 volunteers. RESULTS: Overall, 101 CCAs and 79 ICAs were available for comparison. MR imaging underestimated (P < .05) systolic CCA and ICA blood flow velocity by 26% (0.79 +/- 0.29 m/s vs 1.06 +/- 0.31 m/s) and 19% (0.72 +/- 0.21 m/s vs 0.89 +/- 0.27 m/s) compared with US. Diastolic blood flow velocities were similar for MR imaging and US (differences, 9% and 3%, respectively; not significant). Reproducibility and interobserver agreement of 4D flow MR imaging was excellent. CONCLUSIONS: 4D flow MR imaging allowed for an accurate measurement of blood flow velocities in the carotid bifurcation of both volunteers and patients with only moderate underestimation compared with US. Thus, 4D flow MR imaging seems promising for a future combination with MRA to comprehensively assess ICA stenosis and related hemodynamic changes.
引用
收藏
页码:1407 / 1413
页数:7
相关论文
共 22 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Bock J, 2007, ANN M INT SOC MAGN R, P3138
[3]   4D Phase Contrast MRI at 3 T: Effect of Standard and Blood-Pool Contrast Agents on SNR, PC-MRA, and Blood Flow Visualization [J].
Bock, Jelena ;
Frydrychowicz, Alex ;
Stalder, Aurelien F. ;
Bley, Thorsten A. ;
Burkhardt, Hans ;
Hennig, Juergen ;
Markl, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) :330-338
[4]   Noninvasive MR imaging of cerebral perfusion in patients with a carotid artery stenosis [J].
Bokkers, R. P. H. ;
van der Worp, H. B. ;
Mali, W. P. T. M. ;
Hendrikse, J. .
NEUROLOGY, 2009, 73 (11) :869-875
[5]   Velocity Measurements in the Middle Cerebral Arteries of Healthy Volunteers Using 3D Radial Phase-Contrast HYPRFlow: Comparison with Transcranial Doppler Sonography and 2D Phase-Contrast MR Imaging [J].
Chang, W. ;
Landgraf, B. ;
Johnson, K. M. ;
Kecskemeti, S. ;
Wu, Y. ;
Velikina, J. ;
Rowley, H. ;
Wieben, O. ;
Mistretta, C. ;
Turski, P. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :54-59
[6]   Four-dimensional phase contrast magnetic resonance angiography: Potential clinical applications [J].
Frydrychowicz, Alex ;
Francois, Christopher J. ;
Turski, Patrick A. .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (01) :24-35
[7]   MR derived volumetric flow rate waveforms at locations within the common carotid, internal carotid, and basilar arteries [J].
Gwilliam, Matthew N. ;
Hoggard, Nigel ;
Capener, David ;
Singh, Pankaj ;
Marzo, Alberto ;
Verma, Prashant K. ;
Wilkinson, Iain D. .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 (12) :1975-1982
[8]   3D Blood Flow Characteristics in the Carotid Artery Bifurcation Assessed by Flow-Sensitive 4D MRI at 3T [J].
Harloff, A. ;
Albrecht, F. ;
Spreer, J. ;
Stalder, A. F. ;
Bock, J. ;
Frydrychowicz, A. ;
Schoellhorn, J. ;
Hetzel, A. ;
Schumacher, M. ;
Hennig, J. ;
Markl, M. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) :65-74
[9]   Comparative velocity investigations in cerebral arteries and aneurysms: 3D phase-contrast MR angiography, laser Doppler velocimetry and computational fluid dynamics [J].
Hollnagel, Dorothea I. ;
Summers, Paul E. ;
Poulikakos, Dimos ;
Kollias, Spyros S. .
NMR IN BIOMEDICINE, 2009, 22 (08) :795-808
[10]   Improved 3D Phase Contrast MRI With Off-Resonance Corrected Dual Echo VIPR [J].
Johnson, Kevin M. ;
Lum, Darren P. ;
Turski, Patrick A. ;
Block, Walter F. ;
Mistretta, Charles A. ;
Wieben, Oliver .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1329-1336