Different Bleeding Patterns with the Use of Levonorgestrel Intrauterine System: Are They Associated with Changes in Uterine Artery Blood Flow?

被引:8
作者
Bastianelli, Carlo [1 ]
Farris, Manuela [1 ,2 ]
Rapiti, Stefania [1 ,2 ]
Vecchio, Roberta Bruno [1 ]
Benagiano, Giuseppe [1 ]
机构
[1] Univ Roma La Sapienza, Dept Gynaecol Obstet & Urol, I-00161 Rome, Italy
[2] Assoc Italiana Educ Demog, I-00187 Rome, Italy
关键词
SUBENDOMETRIAL MICROVASCULARIZATION; HUMAN-ENDOMETRIUM; POWER DOPPLER; DEVICE; MENORRHAGIA; HEALTH; WOMEN; IUD;
D O I
10.1155/2014/815127
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. Evaluate if different bleeding patterns associated with the use of the levonorgestrel intrauterine system (LNG-IUS) are associated with different uterine and endometrial vascularization patterns, as evidenced by ultrasound power Doppler analysis. Methodology. A longitudinal study, with each subject acting as its own control was conducted between January 2010 and December 2012. Healthy volunteers with a history of heavy but cyclic and regular menstrual cycles were enrolled in the study. Ultrasonographic examination was performed before and after six months of LNG-IUS placement: uterine volume, endometrial thickness, and subendometrial and myometrial Doppler blood flow patterns have been evaluated. Results. A total of 32 women were enrolled out of 186 initially screened. At six months of follow-up, all subjects showed a reduction in menstrual blood loss; for analysis, they were retrospectively divided into 3 groups: normal cycling women (Group I), amenorrheic women (Group II), and women with prolonged bleedings (Group III). Intergroup analysis documented a statistically significant difference in endometrial thickness among the three groups; in addition, mean pulsatility index (PI) and resistance index (RI) in the spiral arteries were significantly lower in Group I and Group III compared to Group II. This difference persisted also when comparing-within subjects of Group III-mean PI and RI mean values before and after insertion. Conclusions. The LNG-IUS not only altered endometrial thickness, but-in women with prolonged bleedings-also significantly changed uterine artery blood flow. Further studies are needed to confirm these results and enable gynecologists to properly counsel women, improving initial continuation rates.
引用
收藏
页数:6
相关论文
共 32 条
[1]   LEVONORGESTREL-RELEASING INTRAUTERINE-DEVICE IN THE TREATMENT OF MENORRHAGIA [J].
ANDERSSON, JK ;
RYBO, G .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (08) :690-694
[2]   Advance information improves user satisfaction with the levonorgestrel intrauterine system [J].
Backman, T ;
Huhtala, S ;
Luoto, R ;
Tuominen, J ;
Rauramo, I ;
Koskenvuo, M .
OBSTETRICS AND GYNECOLOGY, 2002, 99 (04) :608-613
[3]   THE ANALYSIS OF MENSTRUAL BLEEDING PATTERNS - A REVIEW (REPRINTED FROM APPLIED STOCHASTIC-MODELS AND DATA-ANALYSIS VOL 3, PG 125-150, 1987) [J].
BELSEY, EM ;
FARLEY, TMM .
CONTRACEPTION, 1988, 38 (02) :129-156
[4]   Morphological and functional features of endometrial decidualization following long-term intrauterine levonorgestrel delivery [J].
Critchley, HOD ;
Wang, H ;
Jones, RL ;
Kelly, RW ;
Drudy, TA ;
Gebbie, AE ;
Buckley, CH ;
McNeilly, AS ;
Glasier, AF .
HUMAN REPRODUCTION, 1998, 13 (05) :1218-1224
[5]   Three-dimensional power Doppler study of endometrial and subendometrial microvascularization in women with intrauterine device-induced menorrhagia [J].
El-Mazny, Akmal ;
Abou-Salem, Nermeen ;
ElShenoufy, Hossam .
FERTILITY AND STERILITY, 2013, 99 (07) :1912-1915
[6]   Levonorgestrel-releasing (20 μg/day) intrauterine systems (Mirena) compared with other methods of reversible contraceptives [J].
French, RS ;
Cowan, FM ;
Mansour, D ;
Higgins, JPT ;
Robinson, A ;
Procter, T ;
Morris, S ;
Guillebaud, J .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2000, 107 (10) :1218-1225
[7]   The effect of the levonorgestrel intrauterine system on uterine artery blood flow 1 year after insertion [J].
Haberal, A ;
Kayikcioglu, F ;
Gunes, M ;
Kaplan, M ;
Ozdegirmenci, O .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (03) :316-319
[8]   Comparison of uterine artery blood flow with levonorgestrel intrauterine system and copper intrauterine device [J].
Haliloglu, Berna ;
Celik, Aygen ;
Ilter, Erdin ;
Bozkurt, Serpil ;
Ozekici, Umit .
CONTRACEPTION, 2011, 83 (06) :578-581
[9]   The effect of a levonorgestrel-releasing intrauterine system on uterine artery blood flow, hormone concentrations and ovarian cyst formation in fertile women [J].
Järvelä, I ;
Tekay, A ;
Jouppila, P .
HUMAN REPRODUCTION, 1998, 13 (12) :3379-3383
[10]   The effects of a copper-intrauterine device on the uterine artery blood flow in regularly menstruating women [J].
Järvelä, I ;
Tekay, A ;
Jouppila, P .
HUMAN REPRODUCTION, 1998, 13 (07) :1841-1845