Postural Change in Intraocular Pressure: A Comparison of Measurement With a Goldmann Tonometer, Tonopen XL, Pneumatonometer, and HA-2

被引:23
|
作者
Barkana, Yaniv [1 ]
机构
[1] Assaf Harofe Med Ctr, Dept Ophthalmol, IL-70300 Zerifin, Israel
关键词
postural; intraocular pressure; Goldmann; pneumatonometer; Tonopen; Perkins; CENTRAL CORNEAL THICKNESS; OPEN-ANGLE GLAUCOMA; BODY POSITION; AGREEMENT; OFFICE; PATTERN; HEAD; IOP;
D O I
10.1097/IJG.0b013e3182a0762f
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To compare directly the results of 4 tonometers in measuring postural change in the intraocular pressure (IOP) between sitting and lying body positions.Methods:In 19 healthy subjects, the IOP was measured both eyes with a Goldmann applanation tonometer (GAT) while sitting, then using the same GAT with the subject in the left lateral decubitus position after lying for 15 minutes, using a novel system comprising a motorized bed and a modified slit-lamp table. On the next day, the sitting IOP was measured in 1 eye using GAT, and additionally in random order Tonopen XL and pneumatonometer. Then subjects were asked to lie down, and the IOP was measured with these tonometers and also with a hand-held applanation tonometer (HA-2) after lying for 15 minutes and for 45 minutes; measurements were made with subjects in the supine position except with GAT.Results:There were 10 male and 9 female subjects, with a mean age of 33.012.4 years. On day 1, the sitting GAT IOP (mm Hg) was 13.7 +/- 3.0 right eye and 13.6 +/- 2.8 left eye (P=0.7) and the lying GAT IOP was 17.8 +/- 3.5 right eye and 18.1 +/- 3.2 left eye (P=0.3 for inter-eye postural IOP change). Postural change in the right and the left eyes was moderately correlated, with a coefficient of 0.453. On day 2, postural changes after lying for 15 minutes as measured with a GAT, a Tonopen, a pneumatonometer, and a HA-2 were 4.9 +/- 2.6, 1.6 +/- 1.8, 4.2 +/- 2.0, and 3.1 +/- 2.7, respectively. After lying for 45 minutes, it decreased to 3.3 +/- 2.1, 1.1 +/- 4.3, 3.1 +/- 2.5, and 2.6 +/- 3.3, respectively; this IOP decrease was statistically significant for the GAT and the pneumatonometer. The inter-subject variability was large, as in some subjects there was nearly no postural change in the IOP, whereas in some the IOP increased by 8 to 10 mm Hg. Ninety-five percent limits of agreement showed a poor agreement between GAT and the other 3 tonometers in the sitting and lying IOPs and postural IOP changes measured.Conclusions:The average postural IOP change was similar when measured with GAT and a pneumatonometer, smaller with a hand-held GAT, and much smaller with a Tonopen XL. This change decreased significantly when lying between the 15- and 45-minute time points. The inter-subject variability in postural IOP was remarkable, consistent with previous reports, suggesting the importance of this parameter in clinical glaucoma practice. Inter-device agreement was poor and similar to previous reports.
引用
收藏
页码:E23 / E28
页数:6
相关论文
共 50 条
  • [1] Measurement of the difference in intraocular pressure between the sitting and lying body positions in healthy subjects: direct comparison of the Icare Pro with the Goldmann applanation tonometer, Pneumatonometer and Tonopen XL
    Barkana, Yaniv
    Gutfreund, Shay
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07) : 608 - 614
  • [2] Comparison of Goldmann Applanation Tonometer, Noncontact Tonometer, and TonoPen XL for Intraocular Pressure Measurement in Different Types of Glaucomatous, Ocular Hypertensive, and Normal Eyes
    Kim, Na Rae
    Kim, Chan Yun
    Kim, Hyunjoong
    Seong, Gong Je
    Lee, Eun Suk
    CURRENT EYE RESEARCH, 2011, 36 (04) : 295 - 300
  • [3] New TonoPen XL: comparison with the Goldmann tonometer
    Iester, M
    Mermoud, A
    Achache, F
    Roy, S
    EYE, 2001, 15 (1) : 52 - 58
  • [4] New TonoPen XL: Comparison with the Goldmann tonometer
    Michele Iester
    Andre Mermoud
    Farid Achache
    Sylvain Roy
    Eye, 2001, 15 : 52 - 58
  • [5] Comparison of Disposable Goldmann Applanation Tonometer, ICare ic100, and Tonopen XL to Standards of Care Goldmann Nondisposable Applanation Tonometer for Measuring Intraocular Pressure
    Wong, Benny
    Parikh, Deep
    Rosen, Lisa
    Gorski, Matthew
    Angelilli, Allison
    Shih, Carolyn
    JOURNAL OF GLAUCOMA, 2018, 27 (12) : 1119 - 1124
  • [6] Measurements of Intraocular Pressure by Goldmann Tonometry, Tonopen XL, and the Transpalpebral Tonometer, TGDc-01. After Penetrating Keratoplasty: A Comparativye Study
    Shemesh, Gabi
    Waisbourd, Michael
    Varssano, David
    Michaeli, Adi
    Lazar, Moshe
    Kurtz, Shimon
    CORNEA, 2009, 28 (07) : 724 - 727
  • [7] Central corneal thickness and intraocular pressure relationship in eyes with and without previous LASIK: Comparison of Goldmann applanation tonometer with pneumatonometer
    Baypaktar, S
    Bayraktar, Z
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (01) : 81 - 88
  • [8] Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
    Ohana, Oded
    Varssano, David
    Shemesh, Gabi
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (07) : 579 - 583
  • [9] Clinical comparison of ocular blood flow tonometer, tonopen, and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes
    Rao, VJ
    Gnanaraj, L
    Mitchell, KW
    Figueiredo, FC
    CORNEA, 2001, 20 (08) : 834 - 838
  • [10] Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in cats
    Ricci, Claudia Lizandra
    Giuffrida, Rogerio
    Kanashiro, Glaucia Prada
    Rufino Belezzi, Hilidia Stephania
    Bacarin, Carolina de Carvalho
    Tenorio, Michele Paulo
    Duran Foglia, Bruna Toledo
    Andrade, Silvia Franco
    SEMINA-CIENCIAS AGRARIAS, 2017, 38 (06): : 3647 - 3655