Bond Performance of Sand Coated UHM CFRP Tendons in High Performance Concrete

被引:8
|
作者
Lammlein, Tobias Dominik [1 ,2 ]
Messina, Francesco [3 ]
Griffa, Michele [4 ,5 ]
Terrasi, Giovanni Pietro [1 ,6 ]
Lura, Pietro [2 ,4 ]
机构
[1] Swiss Fed Labs Mat Sci & Technol, Empa, Mech Syst Engn Lab, Uberlandstr 129, CH-8600 Dubendorf, Switzerland
[2] Swiss Fed Inst Technol, Inst Bldg Mat IfB, CH-8092 Zurich, Switzerland
[3] Pathenope Univ Naples, Dept Engn, I-80143 Naples, Italy
[4] Swiss Fed Labs Mat Sci & Technol, Empa, Concrete & Construct Chem Lab, Uberlandstr 129, CH-8600 Dubendorf, Switzerland
[5] Swiss Fed Labs Mat Sci & Technol, Empa, Ctr Xray Analyt, Uberlandstr 129, CH-8600 Dubendorf, Switzerland
[6] Univ Edinburgh, Sch Engn, Inst Infrastruct & Environm, Edinburgh EH9 3FB, Midlothian, Scotland
基金
瑞士国家科学基金会;
关键词
CFRP; UHM carbon fibre; UTS carbon fibre; prestressing tendon; sand coated; bond; HPC; pull-out test; finite element modelling (FEM); X-ray tomography; BEHAVIOR; BARS; POLYMERS; STRENGTH; LENGTHS;
D O I
10.3390/polym9020078
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The bond behaviour of novel, sand-coated ultra-high modulus (UHM) carbon fibre reinforced polymers (CFRP) tendons to high performance concrete (HPC) was studied by a combined numerical and experimental approach. A series of pull-out tests revealed that the failure type can vary between sudden and continuous pull-out depending on the chosen sand coating grain size. Measuring the same shear stress vs. tendon draw-in (tau-delta) curves in the same test set-up, for sand coated CFRP tendons with a longitudinal stiffness of 137 and 509 GPa, respectively, indicated that the absolute bond strength in both cases was not influenced by the tendon ' s stiffness. However, the tau-delta curves significantly differed in terms of the draw-in rate, showing higher draw-in rate for the UHM CFRP tendon. With the aid of X-ray computed tomography (CT), scanning electron microscopy (SEM) and visual analysis methods, the bond failure interface was located between the CFRP tendon and the surrounding sand-epoxy layer. For further investigation, a simplified finite element analysis (FEA) of the tendon pull-out was performed using a cohesive surface interaction model and the software Abaqus 6.14. A parametric study, varying the tendon-related material properties, revealed the tendon ' s longitudinal stiffness to be the only contributor to the difference in the tau-delta curves found in the experiments, thus to the shear stress transfer behaviour between the CFRP tendon and the concrete. In conclusion, the excellent bond of the sand-coated UHM CFRP tendons to HPC as well as the deeper insight in the bond failure mechanism encourages the application of UHM CFRP tendons for prestressing applications.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] A numerical investigation on the performance of composite anchors for CFRP tendons
    Cai, Dong-sheng
    Xu, Zhao-hui
    Yin, Jie
    Liu, Rong-gui
    Liang, Ge
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 112 : 848 - 855
  • [32] Influence of service temperature and strain rate on the bond performance of CFRP reinforcement in concrete
    Borosnyoi, Adorjan
    COMPOSITE STRUCTURES, 2015, 127 : 18 - 27
  • [33] Experimental investigation on post-impact bond performance of carbon fiber-reinforced polymer tendons in ultra-high performance concrete
    Fang, Yawei
    Fang, Zhi
    Liu, Pengjie
    Xiang, Yu
    Zhou, Xuhong
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 427
  • [34] Bond performance of quartz sand modified enamel coated plain steel bars with concrete under reversed cyclic loading
    Kuang, Yihang
    Tang, Fujian
    Lin, Weiwei
    Lin, Zhibin
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 421
  • [35] Copper slag as sand replacement for high performance concrete
    Al-Jabri, Khalifa S.
    Hisada, Makoto
    Al-Oraimi, Salem K.
    Al-Saidy, Abdullah H.
    CEMENT & CONCRETE COMPOSITES, 2009, 31 (07): : 483 - 488
  • [36] High-performance concrete made with dune sand
    Kog, Yue Choong
    MAGAZINE OF CONCRETE RESEARCH, 2020, 72 (20) : 1036 - 1046
  • [37] Bond performance of grouted tendons at elevated temperatures
    Wu, Xi-qiang
    Huang, Ting
    Zhang, Li
    Au, Francis Tat Kwong
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2021, 174 (09) : 791 - 803
  • [38] Bond performance between deformed bars and concrete containing iron tailing sand exposed to high temperature
    Zhu, Qian
    Yuan, Yixin
    Chen, Jihao
    Lv, Yajun
    Sun, Xialing
    Duan, Jiayu
    STRUCTURES, 2023, 56
  • [39] Bond between FRP bars and fine-grain high-performance concrete with CFRP mesh confinement
    Holschemacher, K.
    Zhong, H.
    ADVANCES IN ENGINEERING MATERIALS, STRUCTURES AND SYSTEMS: INNOVATIONS, MECHANICS AND APPLICATIONS, 2019, : 1515 - 1519
  • [40] Performance of precast segmental concrete beams posttensioned with carbon fiber-reinforced polymer (CFRP) tendons
    Le, Tan D.
    Pham, Thong M.
    Hao, Hong
    Yuan, Cheng
    COMPOSITE STRUCTURES, 2019, 208 : 56 - 69