Digital camera measurements of soot temperature and soot volume fraction in axisymmetric flames

被引:56
作者
Guo, Haiqing [1 ]
Castillo, Jose A. [1 ]
Sunderland, Peter B. [1 ]
机构
[1] Univ Maryland, Dept Fire Protect Engn, College Pk, MD 20742 USA
基金
美国国家科学基金会;
关键词
THIN-FILAMENT PYROMETRY; DIFFUSION FLAMES; OPTICALLY-THICK; RADIATION; PRESSURES;
D O I
10.1364/AO.52.008040
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
New diagnostics are presented that use a digital camera to measure full-field soot temperatures and soot volume fractions in axisymmetric flames. The camera is a Nikon D700 with 12 megapixels and 14 bit depth in each color plane, which was modified by removing the infrared and anti-aliasing filters. The diagnostics were calibrated with a blackbody furnace. The flame considered here was an 88 mm long ethylene/air co-flowing laminar jet diffusion flame on a round 11.1 mm burner. The resolution in the flame plane is estimated at between 0.1 and 0.7 mm. Soot temperatures were measured from soot radiative emissions, using ratio pyrometry at 450, 650, and 900 nm following deconvolution. These had a range of 1600-1850 K, a temporal resolution of 125 ms, and an estimated uncertainty of +/- 50 K. Soot volume fractions were measured two ways: from soot radiative emissions and from soot laser extinction at 632.8 nm, both following deconvolution. Soot volume fractions determined from emissions had a range of 0.1-10 ppm, temporal resolutions of 125 ms, and an estimated uncertainty of +/- 30%. Soot volume fractions determined from laser extinction had a range of 0.2-10 ppm, similar temporal resolutions, and an estimated uncertainty of +/- 10%. The present measurements agree with past measurements in this flame using traversing optics and probes; however, they avoid the long test times and other complications of such traditional methods. (C) 2013 Optical Society of America
引用
收藏
页码:8040 / 8047
页数:8
相关论文
共 27 条
[1]   Field measurements of soot volume fractions in laminar partially premixed coflow ethylene/air flames [J].
Arana, CP ;
Pontoni, M ;
Sen, S ;
Puri, IK .
COMBUSTION AND FLAME, 2004, 138 (04) :362-372
[2]  
Coffin D., Decoding raw digital photos in Linux
[3]  
Connelly B.C., 2005, JOINT M US SECT COMB
[4]   LIGHT-SCATTERING METHOD FOR SOOT CONCENTRATION MEASUREMENTS [J].
DALZELL, WH ;
WILLIAMS, GC ;
HOTTEL, HC .
COMBUSTION AND FLAME, 1970, 14 (1-3) :161-&
[5]   Determination of the soot volume fraction in an ethylene diffusion flame by multiwavelength analysis of soot radiation [J].
De Iuliis, S ;
Barbini, M ;
Benecchi, S ;
Cignoli, F ;
Zizak, G .
COMBUSTION AND FLAME, 1998, 115 (1-2) :253-261
[6]   Soot properties of laminar jet diffusion flames in microgravity [J].
Diez, F. J. ;
Aalburg, C. ;
Sunderland, P. B. ;
Urban, D. L. ;
Yuan, Z. -G. ;
Faeth, G. M. .
COMBUSTION AND FLAME, 2009, 156 (08) :1514-1524
[7]   DETERMINATION OF RADIAL PROFILE OF ABSORPTION AND EMISSION COEFFICIENTS AND TEMPERATURE IN CYLINDRICALLY SYMMETRIC SOURCES WITH SELF-ABSORPTION [J].
ELDER, P ;
JERRICK, T ;
BIRKELAN.JW .
APPLIED OPTICS, 1965, 4 (05) :589-&
[8]   Theoretical evaluation of measurement uncertainties of two-color pyrometry applied to optical diagnostics [J].
Fu, Tairan ;
Cheng, Xiaofang ;
Yang, Zangjian .
APPLIED OPTICS, 2008, 47 (32) :6112-6123
[9]   Soot volume fraction imaging [J].
Greenberg, PS ;
Ku, JC .
APPLIED OPTICS, 1997, 36 (22) :5514-5522
[10]   Soot formation and temperature field structure in co-flow laminar methane-air diffusion flames at pressures from 10 to 60 atm [J].
Joo, Hyun I. ;
Guelder, Oemer L. .