Macrogeometric Differentiation of Dental Implant Primary Stability: An In Vitro Study

被引:13
作者
Al-Tarawneh, Sandra K. [1 ,2 ]
Thalji, Ghadeer [1 ]
Cooper, Lyndon F. [3 ]
机构
[1] Univ Illinois, Coll Dent, Dept Restorat Dent, Chicago, IL USA
[2] Univ Jordan, Dept Prosthodont, Amman, Jordan
[3] Univ Illinois, Dept Oral Biol, Coll Dent, Chicago, IL USA
关键词
dental implant; in vitro; insertion torque; macrogeometry; primary stability; INSERTION TORQUE; BONE; SURFACE; THREAD; OSSEOINTEGRATION;
D O I
10.11607/jomi.9656
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate an alternative cutting, progressive thread design to increase primary stability in low-density bone. Materials and Methods: Four different implants with different macrogeometries (Nobel Biocare Active [NA] Internal RP implants [4.3 x 11.5 mm], Straumann BLX Roxolid RB implants [4.5 x 10 mm], Astra Tech Implant EV implants [4.2 x 11 mm], and PrimeTaper [PT 4.2 x 11 mm]) were placed in simulated osteotomies and extraction sockets in synthetic bone (Sawbones) according to the manufacturers' protocol. Insertion torque and ISQ values were measured using Implantmed Plus motor and Ostell IDX, respectively. Insertion time was recorded. Average values were calculated and compared using ANOVA and Tukey test. Results: Insertion torque (range: 5 to 44 Ncm) increased with increasing synthetic bone density for all implants. Different ISQ values in synthetic low-density bone were not observed in higher-density synthetic bone. Insertion torque of all implants was reduced when implants were placed in simulated sockets compared to simulated osteotomies. In both low- density and higher-density synthetic bone, the primary stability of PrimeTaper implants with cutting and progressive thread design was equivalent to that of the Nobel Biocare NobelActive implant with compressive thread design and greater than the BLX implant with compressive thread design. Conclusion: Different implant macrogeometries obtain relatively high primary stability in low-density bone when measured by ISQ. Double-thread implant designs reduce insertion times in higher-density bone. A cutting and progressive compressing thread design provides density-sensing performance compared to aggressive condensing thread designs. This macrogeometry can achieve high primary stability associated with modest insertion torque compared to aggressive threaded implant designs known to attain the highest insertion torque. The presence of multiple cutting threads may offer advantages in obtaining primary stability in low-density bone.
引用
收藏
页码:1110 / 1118
页数:9
相关论文
共 44 条
[1]   The effect of thread pattern upon implant osseointegration [J].
Abuhussein, Heba ;
Pagni, Giorgio ;
Rebaudi, Alberto ;
Wang, Hom-Lay .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) :129-136
[2]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[3]  
Albrektsson T, 2004, INT J PROSTHODONT, V17, P536
[4]   Implant Compression Necrosis: Current Understanding and Case Report [J].
Bashutski, Jill D. ;
D'Silva, Nisha J. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :700-704
[5]  
Bavetta Giuseppe, 2019, Biomed Res Int, V2019, P9720419, DOI 10.1155/2019/9720419
[6]   Assessment of Lateral Rotation Percentage and Rotational Deformity of the Elbow in Type 3 Supracondylar Humerus Fractures: A Biomechanical Study [J].
Berdis, Galen ;
Hooper, Matthew ;
Talwalkar, Vishwas ;
Walker, Janet ;
Muchow, Ryan ;
Riley, Scott ;
Iwinski, Henry J. ;
Prusick, Vincent .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2021, 41 (08) :E605-E609
[7]  
Branemark P-I, 1985, TISSUE INTEGRATED PR, P202
[8]  
Brunski J B, 1999, Adv Dent Res, V13, P99
[9]   Characterization of commercial rigid polyurethane foams used as bone analogs for implant testing [J].
Calvert, Kayla L. ;
Trumble, Kevin P. ;
Webster, Thomas J. ;
Kirkpatrick, Lynn A. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2010, 21 (05) :1453-1461
[10]   Clinical Significance of the Use of Resonance Frequency Analysis in Assessing Implant Stability: A Systematic Review [J].
Chen, Maggie Hsiao-Mei ;
Lyons, Karl M. ;
Tawse-Smith, Andrew ;
Ma, Sunyoung .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (01) :51-+