Evaluation of a new microbeads assay for granulocyte antibody detection

被引:17
|
作者
Schulz, Undine [1 ]
Reil, Angelika [2 ]
Kiefel, Volker [3 ]
Bux, Juergen [4 ]
Moog, Rainer [1 ]
机构
[1] DRK Blood Serv North East, Cottbus, Germany
[2] DRK Blood Serv West, Hagen, Germany
[3] Univ Rostock, Dept Transfus Med, Rostock, Germany
[4] Ruhr Univ Bochum, Bochum, Germany
关键词
ACUTE LUNG INJURY; TRANSPORTER-LIKE PROTEIN-2; TRANSFECTED CELL-LINES; TRALI; ALLOANTIBODIES; PATHOGENESIS; FATALITIES; MODEL; 5B;
D O I
10.1111/trf.13878
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To reduce the risk of transfusion-associated acute lung injury (TRALI), a high number of plasma donors were tested for human leukocyte antigen (HLA) and human neutrophil antigen (HNA) antibodies. For HNA antibody detection, the gold standard is a combination of the granulocyte immunofluorescence test (GIFT) and the granulocyte agglutination test (GAT). However, these tests are not suitable for a high-throughput of samples. STUDY DESIGN AND METHODS: To evaluate the new generation of the LABScreen MULTI assay (One Lambda, Inc.), which has special new beads for all the known HNA specificities, including HNA-3a, 97 sera samples containing well-defined HNA antibodies were used. For background testing, we used 91 samples from plasma donors previously identified by GAT, GIFT, and the monoclonal antibody-specific immobilization of granulocyte antigens (MAIGA) assay. RESULTS: Compared with previous tests, the new LABScreen MULTI assay was highly specific for the HNA-1a, HNA-1b, HNA-2, and HNA-3a antibody specificities required to prevent TRALI. Ninety-eight percent of the HNA-1a, HNA-1b, and HNA-2 antibodies could be detected as true positive; and 90% of the HNA-3a antibodies were recognized correctly as positive. False-positive reactions were identified in 5.5% of samples that previously tested negative. CONCLUSION: The detection of HNA-3a antibody specificities could be integrated into the new LABScreen MULTI assay; however, we detected only 90%. In addition, we detected further HNA antibodies, such as HNA-1c, HNA-1d, and some HNA-3b and HNA-4a antibodies. The new generation of LABScreen MULTI is a great step toward feasible high-throughput testing for HNA antibodies. Nevertheless, GIFT and GAT remain the gold-standard methods for the differentiation of rare and currently unknown HNA specificities.
引用
收藏
页码:70 / 81
页数:12
相关论文
共 50 条
  • [21] Recommendations of the ISBT Working Party on Granulocyte Immunobiology for leucocyte antibody screening in the investigation and prevention of antibody-mediated transfusion-related acute lung injury
    Bierling, P.
    Bux, J.
    Curtis, B.
    Flesch, B.
    Fung, I.
    Lucas, G.
    Macek, M.
    Muniz-Diaz, E.
    Porcelijn, I.
    Reil, A.
    Sachs, U.
    Schuller, R.
    Tsuno, N.
    Uhrynowska, M.
    Urbaniak, S.
    Valentin, N.
    Wikman, A.
    Zupanska, B.
    VOX SANGUINIS, 2009, 96 (03) : 266 - 269
  • [22] Antibody-Free Targeted Proteomics Assay for Absolute Measurement of α-Tubulin Acetylation
    Shah, Alok K.
    Wali, Gautam
    Sue, Carolyn M.
    Mackay-Sim, Alan
    Hill, Michelle M.
    ANALYTICAL CHEMISTRY, 2020, 92 (16) : 11204 - 11212
  • [23] A new approach to ELISA-based anti-glycolipid antibody evaluation of highly adhesive serum samples
    Usuki, Seigo
    O'Brien, Dawn
    Rivner, Michael H.
    Yu, Robert K.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2014, 408 : 52 - 63
  • [24] An association between ABO group and HLA antibody detection
    Dunbar, Nancy M.
    Yazer, Mark H.
    Bravo, Marjorie D.
    Kamel, Hany T.
    Gorlin, Jed
    Norris, Philip J.
    Williamson, Phillip C.
    Vassallo, Ralph R.
    TRANSFUSION, 2017, 57 (02) : 313 - 318
  • [25] Evaluation of poly- and monoclonal antibody-based sandwich enzyme-linked immunosorbent assay (ELISA) for their performance to detect crustacean residues in processed foods
    Zhao, Jinlong
    Li, Yonghong
    Li, Ranran
    Timira, Vaileth
    Dasanayaka, Binaka Prabashini
    Zhang, Ziye
    Zhang, Jiukai
    Lin, Hong
    Li, Zhenxing
    FOOD CONTROL, 2022, 138
  • [26] A Combined In Vitro Assay for Evaluation of Neurotrophic Activity and Cytotoxicity
    Chaurasiya, Narayan D.
    Shukla, Surabhi
    Tekwani, Babu L.
    SLAS DISCOVERY, 2017, 22 (06) : 667 - 675
  • [27] Qualification of a free ligand assay in the presence of anti-ligand antibody Fab fragments
    Hansen, Ryan J.
    Brown, Robin M.
    Lu, Jirong
    Wroblewski, Victor J.
    MABS, 2013, 5 (02) : 288 - 296
  • [28] A New Method for Detection and Evaluation of Winding Mechanical Faults in Transformer through Transfer Function Measurements
    Bigdeli, Mehdi
    Vakilian, Mehdi
    Rahimpour, Ebrahim
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2011, 11 (02) : 23 - 30
  • [29] Development and evaluation of loop-mediated isothermal amplification assay for rapid and sensitive detection of canine parvovirus DNA directly in faecal specimens
    Mukhopadhyay, H. K.
    Amsaveni, S.
    Matta, S. L.
    Antony, P. X.
    Thanislass, J.
    Pillai, R. M.
    LETTERS IN APPLIED MICROBIOLOGY, 2012, 55 (03) : 202 - 209
  • [30] A standardized immunofluorescence test method with human neutrophil antigen-expressing cell lines to enhance antibody detection
    Lopez, G. H.
    Dean, M. M.
    Yasui, K.
    Schuller, R. M.
    Hirayama, F.
    Fung, Y. L.
    VOX SANGUINIS, 2012, 102 (02) : 171 - 174