Evaluation of sonographically guided percutaneous core biopsy of renal masses

被引:88
|
作者
Caoili, EM [1 ]
Bude, RO [1 ]
Higgins, EJ [1 ]
Hoff, DL [1 ]
Nghiem, HV [1 ]
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
D O I
10.2214/ajr.179.2.1790373
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our objective was to determine the utility of sonographically guided percutaneous core biopsy to evaluate renal masses. MATERIALS AND METHODS. We conducted a retrospective analysis of our imaging-guided procedures from January 1999 to June 2001. We performed 26 sonographically guided percutaneous core biopsies of renal masses in 26 patients. From two to five specimens were obtained from a single mass in each patient using an 18-gauge automated biopsy system. We examined the patients' medical records, pathology results, and imaging studies. Core biopsy results were compared with surgical pathology (n = 6) or clinical follow-up (n = 20). RESULTS. All biopsies provided sufficient material for analysis. Biopsy findings were positive for malignancy in 19 (73%) of 26 masses. Histologic diagnoses included renal cell carcinoma were (n = It), metastasis (n = 3), lymphoma (n = 2), and transitional cell carcinoma (n = 2). Specific cell type characterization could not be made on one biopsy, but the specimens were highly suspicious for malignancy. Biopsy revealed seven (27%) of 26 benign diagnoses: oncocytoma (n = 3), angiomyolipoma (n = 2), and fibrosis (n = 2). The average follow-up period for patients with benign diagnoses was 10 months. One case of surgically proven necrotic pyelonephritis was mischaracterized as fibrosis at core biopsy. Sonographically guided percutaneous core biopsy of renal masses showed a sensitivity of 100% and a specificity of 100% for the diagnosis of malignancy. The core specimens yielded a specific diagnosis in 92% (24/26) of masses. No immediate complications occurred after the procedure. One patient developed a pseudoaneurysm that presented 3 months after the biopsy. CONCLUSION. Sonographically guided percutaneous core biopsy is a reliable and accurate method for evaluating renal masses.
引用
收藏
页码:373 / 378
页数:6
相关论文
共 50 条
  • [31] Evaluation of imaging-guided core biopsy of pancreatic masses
    Paulsen, Sean D.
    Nghiem, Hanh V.
    Negussie, Edsa
    Higgins, Ellen J.
    Caoili, Elaine M.
    Francis, Isaac R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) : 769 - 772
  • [32] Evaluation of imaging-guided core biopsy of pelvic masses
    Yarram, SG
    Nghiem, HV
    Higgins, E
    Fox, G
    Francis, IR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 58 - 59
  • [33] Percutaneous core biopsy for renal masses: Indications, accuracy and results - Comment
    Wagner, Kristofer R.
    Jarrett, Thomas W.
    JOURNAL OF UROLOGY, 2007, 178 (04): : 1188 - 1188
  • [34] Evaluation of imaging-guided core biopsy of pelvic masses
    Yarram, Sai G.
    Nghiem, Hanh V.
    Higgins, Ellen
    Fox, Giovanna
    Nan, Bin
    Francis, Isaac R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : 1208 - 1211
  • [35] What Is the Role of Percutaneous Needle Core Biopsy in Diagnosis of Renal Masses?
    Sofikerim, Mustafa
    Tatlisen, Atila
    Canoz, Ozlem
    Tokat, Fatma
    Demirtas, Abdullah
    Mavili, Ertugrul
    UROLOGY, 2010, 76 (03) : 614 - 618
  • [36] WHAT IS THE ROLE OF PERCUTANEOUS NEEDLE CORE BIOPSY IN DIAGNOSIS OF RENAL MASSES?
    Sofikerim, Mustafa
    Tatlisen, Atila
    Canoz, Ozlem
    Tokat, Fatma
    TURKISH JOURNAL OF UROLOGY, 2007, 33 (04): : 405 - 410
  • [37] Accuracy of Percutaneous Core Biopsy in Management of Small Renal Masses COMMENT
    Glassman, Deborah T.
    UROLOGY, 2009, 73 (03) : 590 - 591
  • [38] SONOGRAPHICALLY DETECTED CHANGES FOLLOWING PERCUTANEOUS RENAL BIOPSY
    SCHWAIGHOFER, B
    FRUHWALD, F
    KOVARIK, J
    ULTRASCHALL IN DER MEDIZIN, 1986, 7 (01): : 44 - 47
  • [39] ULTRASOUND GUIDED PERCUTANEOUS RENAL BIOPSY USING AN AUTOMATIC CORE BIOPSY SYSTEM
    DOWD, PE
    MATA, JA
    CROW, A
    CULKIN, DJ
    VENABLE, DD
    JOURNAL OF UROLOGY, 1991, 146 (05): : 1216 - 1217
  • [40] CT GUIDED PERCUTANEOUS CORE-BIOPSY OF RENAL MASSES: SHORT-TERM COMPLICATIONS, A PROSPECTIVE STUDY
    Lang, Erez
    Copel, Laurian
    Berkovitz, Nadav
    Sandbank, Judith
    Gotlieb, Paul
    Leibovici, Dan
    Lindner, Arie
    Zisman, Amnon
    JOURNAL OF UROLOGY, 2010, 183 (04): : E201 - E201