Implant stability and marginal bone level of microgrooved zirconia dental implants: A 3-month experimental study on dogs

被引:12
作者
Arcesio Delgado-Ruiz, Rafael [1 ]
Markovic, Aleksa [2 ]
Luis Calvo-Guirado, Jose [1 ]
Lazic, Zoran [3 ]
Piattelli, Adriano [5 ]
Boticelli, Daniele [4 ]
Eduardo Mate-Sanchez, Jose [1 ]
Negri, Bruno [1 ]
Piedad Ramirez-Fernandez, Maria [1 ]
Misic, Tijana [2 ]
机构
[1] Univ Murcia, Fac Med & Dent, Murcia, Spain
[2] Univ Belgrade, Fac Dent, Belgrade 11000, Serbia
[3] Mil Med Acad, Clin Maxillofacial Oral Surg & Implantol, Belgrade 11002, Serbia
[4] Goeteborg Univ, Fac Odontol, Gothenburg, Sweden
[5] Univ G dAnnunzio, Sch Dent, Chieti, Italy
关键词
dental implants; surface properties; biomechanics; microscopy; electron; scanning; alveolar bone loss; zirconium; titanium; dogs; ORAL IMPLANTS; OSTEOBLAST MORPHOLOGY; PATTERNED TITANIUM; SURFACE; TISSUE; ADHESION; RABBITS; SIZE; OSSEOINTEGRATION; PROLIFERATION;
D O I
10.2298/VSP121003034D
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aim. The modification of implant surfaces could affect mechanical implant stability as well as dynamics and quality of pen-implant bone healing. The aim of this 3-month experimental study in dogs was to investigate implant stability, marginal bone levels and bone tissue response to zirconia dental implants with two laser-micro-grooved intraosseous surfaces in comparison with nongrooved sandblasted zirconia and sandblasted, high-temperature etched titanium implants. Methods. Implant surface characterization was performed using optical interferometric profilometry and energy dispersive X-ray spectroscopy. A total of 96 implants (4 mm in diameter and 10 mm in length) were inserted randomly in both sides of the lower jaw of 12 Fox Hound dogs divided into groups of 24 each: the control (titanium), the group A (sandblasted zirconia), the group B (sandblasted zirconia plus microgrooved neck) and the group C (sandblasted zirconia plus all microgrooved). All the implants were immediately loaded. Insertion torque, periotest values, radiographic crestal bone level and removal torque were recorded during the 3-month follow-up. Qualitative scanning electon microscope (SEM) analysis of the bone-implant interfaces of each group was performed. Results. Insertion torque values were higher in the group C and control implants (p < 0.05). Periotest values increased in all the periods in proportion to the extent of microgrooving as follows: the group C > the control > the group B > the group A (p < 0.05). Radiographic measurements showed minimal crestal bone loss at 3 months for microgrooved zirconia implants (groups C and B) and control implants compared with the group A implants (p < 0.05). The removal torque values increased with time for all the groups as follows: the group C > the control > the group B > the group A (p < 0.05). SEM showed that implant surfaces of the groups B and C had an extra bone growth inside the microgrooves that corresponded to the shape and direction of the microgrooves. Conclusion. The addition of microgrooves to the entire intraosseous surface of zirconia dental implants enhances primary and secondary implant stability, promotes bone tissue ingrowth and preserves crestal bone levels.
引用
收藏
页码:451 / 461
页数:11
相关论文
共 41 条
[1]   Tissue characteristics at microthreaded implants: An experimental study in dogs [J].
Abrahamsson, Ingemar ;
Berglundh, Tord .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2006, 8 (03) :107-113
[2]   State of the art of oral implants [J].
Albrektsson, Tomas ;
sennerby, Lars ;
Wennerberg, Ann .
PERIODONTOLOGY 2000, 2008, 47 :15-26
[3]   Marginal bone loss in relation to the implant neck surface: An update [J].
Aloy-Prosper, Amparo ;
Maestre-Ferrin, Laura ;
Penarrocha-Oltra, David ;
Penarrocha-Diago, Maria .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2011, 16 (03) :E365-E368
[4]   Are ceramic implants a viable alternative to titanium implants? A systematic literature review [J].
Andreiotelli, Marina ;
Wenz, Hans J. ;
Kohal, Ralf-Joachim .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 :32-47
[5]   Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants [J].
Chang, Po-Chun ;
Lang, Niklaus P. ;
Giannobile, William V. .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (01) :1-12
[6]  
Davies JE, 1998, INT J PROSTHODONT, V11, P391
[7]   Femtosecond laser microstructuring of zirconia dental implants [J].
Delgado-Ruiz, R. A. ;
Calvo-Guirado, J. L. ;
Moreno, P. ;
Guardia, J. ;
Gomez-Moreno, G. ;
Mate-Sanchez, J. E. ;
Ramirez-Fernandez, P. ;
Chiva, F. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2011, 96B (01) :91-100
[8]   Load transfer along the bone-dental implant interface [J].
Faegh, Samira ;
Mueftue, Sinan .
JOURNAL OF BIOMECHANICS, 2010, 43 (09) :1761-1770
[9]  
Ferguson SJ, 2008, INT J ORAL MAX IMPL, V23, P1037
[10]   Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs [J].
Gahlert, M. ;
Gudehus, T. ;
Eichhorn, S. ;
Steinhauser, E. ;
Kniha, H. ;
Erhardt, W. .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (05) :662-668