Investigating the use of raw perlite to produce monolithic thermal insulation material

被引:20
作者
Davraz, M. [1 ]
Koru, M. [2 ]
Akdag, A. E. [3 ]
Kilincarslan, S. [4 ]
Delikanli, Y. E. [5 ]
Cabuk, M. [6 ]
机构
[1] Isparta Univ Appl Sci, Senirkent Vocat Sch, Dep Construct, Isparta, Turkey
[2] Isparta Univ Appl Sci, Technol Fac, Dept Mech Engn, Isparta, Turkey
[3] Isparta Univ Appl Sci, Vocat Sch Tech Sci, Isparta, Turkey
[4] Suleyman Demirel Univ, Engn Fac, Dept Civil Engn, Isparta, Turkey
[5] Isparta Univ Appl Sci, Senirkent Vocat Sch, Dep Machinery, Isparta, Turkey
[6] Mersin Univ, Fac Engn, Dep Met & Mat, Mersin, Turkey
关键词
Raw perlite; Monolithic insulation material; Compressive strength; Thermal conductivity; FOAM GLASS;
D O I
10.1016/j.conbuildmat.2020.120674
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigated the production of monolithic thermal insulation material (monoper) using coarse and fine raw perlite. In this research, coarse and fine raw perlite powder was used as a filling material, and sodium hydroxide and a foaming agent were used as chemical additives. The fillers and additives were mixed in different proportions and pressed in a 60 mm-diameter cylindrical mold, and the resulting samples were dried at 105 degrees C in an oven until they reached a constant dry weight. The dried samples were stored in an ash oven over different temperatures and times, and then cooled at a rate of 5 degrees C/min. The volumes of the samples produced were calculated, their masses were determined with precision scales, and then their apparent density was calculated. The compressive strengths of the samples were tested according to the TS EN 826 standard. Pore sizes of the monoper samples were examined by SEM microscope, and the thermal conductivity coefficients were measured by the heat flow meter method. Density changes were determined according to the sintering time and temperature of the monoper samples, and their expansion coefficients were calculated. In addition, the mathematical relationship between the apparent density and the thermal conductivity coefficient for the monoper samples was demonstrated. The apparent density, compressive strength and thermal conductivity of the optimum sample were determined to be 95 kg/m(3), 270 kPa and 0.0396 W/mK, respectively. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:7
相关论文
共 17 条
  • [1] Performance characteristics and practical applications of common building thermal insulation materials
    Al-Homoud, MS
    [J]. BUILDING AND ENVIRONMENT, 2005, 40 (03) : 353 - 366
  • [2] [Anonymous], 2013, 826 TS EN
  • [3] [Anonymous], 2003, 12667 TS EN
  • [4] [Anonymous], 2006, D555006 ASTM INT
  • [5] [Anonymous], 2008, INF HBCD
  • [6] Ari K., 2009, THESIS
  • [7] Preparation of foam glass from waste glass and fly ash
    Bai, Jianguang
    Yang, Xinghua
    Xu, Shaochun
    Jing, Wenjia
    Yang, Jianfeng
    [J]. MATERIALS LETTERS, 2014, 136 : 52 - 54
  • [8] Bynum R.T., 2001, Insulation handbook
  • [9] Karamanos A.K., 2005, EL P HEL 05 TECHN CH
  • [10] Kelly M., 2014, GLASS MINERAL FIBRE