Serum Glycated Albumin to Guide the Diagnosis of Diabetes Mellitus

被引:48
|
作者
Wu, Wan-Chen [1 ]
Ma, Wen-Ya [2 ]
Wei, Jung-Nan [3 ]
Yu, Tse-Ya [4 ]
Lin, Mao-Shin [5 ]
Shih, Shyang-Rong [1 ]
Hua, Cyue-Huei [6 ]
Liao, Ying-Jhu [1 ]
Chuang, Lee-Ming [1 ]
Li, Hung-Yuan [1 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Internal Med, Div Endocrinol, Taipei 100, Taiwan
[2] Cardinal Tien Hosp, Dept Internal Med, Div Endocrinol, New Taipei, Taiwan
[3] Chia Nan Univ Pharm & Sci, Tainan, Taiwan
[4] Far Eastern Mem Hosp, Dept Hlth Management Ctr, New Taipei, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Internal Med, Div Cardiol, Taipei 100, Taiwan
[6] Natl Taiwan Univ Hosp, Yun Lin Branch, Div Clin Pathol, Yunlin, Taiwan
来源
PLOS ONE | 2016年 / 11卷 / 01期
关键词
IRON-DEFICIENCY; LATE PREGNANCY; HEMOGLOBIN; GLUCOSE; VALUES; PREDICTS; INDEX; A1C; FRUCTOSAMINE; PROTEIN-1;
D O I
10.1371/journal.pone.0146780
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In the diagnosis of diabetes mellitus, hemoglobin A1c (HbA1c) is sometimes measured to determine the need of an oral glucose tolerance test (OGTT). However, HbA1c does not accurately reflect glycemic status in certain conditions. This study was performed to test the possibility that measurement of serum glycated albumin (GA) better assesses the need for OGTT. From 2006 to 2012, 1559 subjects not known to have diabetes or to use anti-diabetic medications were enrolled. Serum GA was measured, and a 75-g OGTT was then performed to diagnose diabetes. Serum GA correlated significantly to age (r = 0.27, p<0.001), serum albumin (r = -0.1179, age-adjusted p = 0.001), body mass index (r = -0.24, age-adjusted p<0.001), waist circumference (r = -0.16, age-adjusted p<0.001), and plasma GA (r = 0.999, p<0.001), but was unaffected by diet (p = 0.8). Using serum GA at 15% for diagnosis of diabetes, the sensitivity, specificity, and area under the receiver-operating characteristic curve were 74%, 85%, and 0.86, respectively. Applying a fasting plasma glucose (FPG) value of < 100 mg/dL to exclude diabetes and of >= 126 mg/dL to diagnose diabetes, 14.4% of the study population require an OGTT (OGTT%) with a sensitivity of 78.8% and a specificity of 100%. When serum GA value of 14% and 17% were used to exclude and diagnose diabetes, respectively, the sensitivity improved to 83.3%, with a slightly decrease in specificity (98.2%), but a significant increase in OGTT%(35%). Using combined FPG and serum GA cutoff values (FPG < 100 mg/dL plus serum GA < 15% to exclude diabetes and FPG >= 126 mg/dL or serum GA >= 17% to diagnose diabetes), the OGTT% was reduced to 22.5% and the sensitivity increased to 85.6% with no change in specificity (98.2%). In the diagnosis of diabetes, serum GA measurements can be used to determine the need of an OGTT.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Is there a role for glycated albumin in the diagnosis of gestational diabetes mellitus?
    Fernando Chimela Chume
    Paula Breitenbach Renz
    Mayana Kieling Hernandez
    Priscila Aparecida Correa Freitas
    Joíza Lins Camargo
    Endocrine, 2021, 72 : 681 - 687
  • [2] Is there a role for glycated albumin in the diagnosis of gestational diabetes mellitus?
    Chume, Fernando Chimela
    Renz, Paula Breitenbach
    Hernandez, Mayana Kieling
    Freitas, Priscila Aparecida Correa
    Camargo, Joiza Lins
    ENDOCRINE, 2021, 72 (03) : 681 - 687
  • [3] Glycated albumin and diabetes mellitus
    Furusyo, Norihiro
    Hayashi, Jun
    BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2013, 1830 (12): : 5509 - 5514
  • [4] When Hemoglobin A1c Fails: Serum Glycated Albumin to Guide Oral Glucose Tolerance Tests in the Diagnosis of Diabetes Mellitus
    Ma, Wen-Ya
    Wu, Wan-Chen
    Wei, Jung-Nan
    Lin, Mao-Shin
    Shih, Shyang-Rong
    Hua, Cyue-Huei
    Liao, Ying-Jhu
    Chuang, Lee-Ming
    Li, Hung-Yuan
    DIABETES, 2014, 63 : A358 - A358
  • [5] BLOOD GLYCATED HEMOGLOBIN, SERUM FRUCTOSAMINE, SERUM GLYCATED ALBUMIN AND SERUM GLYCATED TOTAL PROTEIN AS MEASURES OF GLYCEMIA IN DIABETES-MELLITUS
    KOSKINEN, P
    ERKKOLA, R
    VIIKARI, J
    MATTILA, K
    IRJALA, K
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1992, 52 (08): : 863 - 869
  • [6] Aptasensor based optical detection of glycated albumin for diabetes mellitus diagnosis
    Ghosh, Shreya
    Datta, Debopam
    Cheema, Mehar
    Dutta, Mitra
    Stroscio, Michael A.
    NANOTECHNOLOGY, 2017, 28 (43)
  • [7] Graphene based aptasensor for glycated albumin in diabetes mellitus diagnosis and monitoring
    Apiwat, Chayachon
    Luksirikul, Patraporn
    Kankla, Pacharapon
    Pongprayoon, Prapasiri
    Treerattrakoon, Kiatnida
    Paiboonsukwong, Kittiphong
    Fucharoen, Suthat
    Dharakul, Tararaj
    Japrung, Deanpen
    BIOSENSORS & BIOELECTRONICS, 2016, 82 : 140 - 145
  • [8] Serum fructosamine, serum glycated albumin and serum glycated β-lipoprotein in type 2 diabetes mellitus patients with and without microvascular complications
    Kalaria T.R.
    Sirajwala H.B.
    Gohel M.G.
    Journal of Diabetes & Metabolic Disorders, 15 (1):
  • [9] Diagnostic Utility of Serum Glycated Albumin for Diabetes Mellitus and Its Correlation With Hyperlipidemia
    Park, Sholhui
    Lee, Wookeun
    Chung, Hae-Sun
    Hong, Ki-Sook
    ANNALS OF LABORATORY MEDICINE, 2016, 36 (04) : 306 - 312
  • [10] Glycated albumin as a biomarker for diagnosis of diabetes mellitus A systematic review and meta -analysis
    Xiong, Jia-Yao
    Wang, Jun-Mei
    Zhao, Xiao-Lan
    Yang, Chao
    Jiang, Xian-Shu
    Chen, Yan-Mei
    Chen, Chang-Qin
    Li, Zhi-Yong
    WORLD JOURNAL OF CLINICAL CASES, 2021, 9 (31) : 9520 - 9534