Stereological estimation of the total number of ECL cells and related parameters using the smooth, vertical fractionator in the rat oxyntic mucosa

被引:5
作者
Bendtsen, TF
Nyengaard, JR
Grimelius, L
Gundersen, HJG
机构
[1] Aarhus Univ, Stereol Res Lab, DK-8000 Aarhus C, Denmark
[2] Aarhus Univ, Electron Microscopy Lab, Inst Expt Clin Res, DK-8000 Aarhus C, Denmark
[3] Aarhus Univ, Inst Pathol, DK-8000 Aarhus C, Denmark
关键词
disector; ECL cells; fractionator; smooth fractionator; stereology;
D O I
10.1046/j.1365-2818.2002.01053.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
During the last 10 years many attempts have been made to estimate the number of enterochromaffin-like (ECL) cells in various animal studies. This is the first presentation of an unbiased stereological estimator of the total number of histamine-positive ECL cells per rat and linked to estimators of related parameters: total volume of the oxyntic mucosa, total oxyntic mucosal surface area, total oxyntic serosal surface area, surface amplification factor, average thickness of the oxyntic mucosa, total and mean volume of the ECL cells, total number of oxyntic glands and pits, mean number of ECL cells per gland, and mean number of ECL cells and glands per oxyntic serosal surface area. This study is the first application of the smooth fractionator and includes a description of all sources of sampling variance in the smooth fractionator design with newly developed predictors.
引用
收藏
页码:211 / 224
页数:14
相关论文
共 30 条
[1]   ESTIMATION OF SURFACE-AREA FROM VERTICAL SECTIONS [J].
BADDELEY, AJ ;
GUNDERSEN, HJG ;
CRUZORIVE, LM .
JOURNAL OF MICROSCOPY-OXFORD, 1986, 142 :259-276
[2]  
Boycott AE, 1910, J ANAT PHYSIOL, V45, P20
[3]  
CLARKE RM, 1972, J ANAT, V112, P27
[4]   ON THE PRECISION OF SYSTEMATIC-SAMPLING - A REVIEW OF MATHERONS TRANSITIVE METHODS [J].
CRUZORIVE, LM .
JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 :315-333
[5]  
DADDA T, 1989, CELL TISSUE RES, V255, P41
[6]   DETERMINATION OF MEAN MASS CHARACTERISTICS OF PARTICLES OF A SYSTEM OF BODIES BY MEANS OF MEASUREMENTS AT BOUNDARY OF A SECTION [J].
GIGER, H .
ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND PHYSIK, 1967, 18 (06) :883-&
[7]   OPTIMIZING SAMPLING EFFICIENCY OF STEREOLOGICAL STUDIES IN BIOLOGY - OR DO MORE LESS WELL [J].
GUNDERSEN, HJG ;
OSTERBY, R .
JOURNAL OF MICROSCOPY, 1981, 121 (JAN) :65-73
[8]   SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE [J].
GUNDERSEN, HJG ;
BENDTSEN, TF ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (05) :379-394
[9]   THE NEW STEREOLOGICAL TOOLS - DISECTOR, FRACTIONATOR, NUCLEATOR AND POINT SAMPLED INTERCEPTS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS [J].
GUNDERSEN, HJG ;
BAGGER, P ;
BENDTSEN, TF ;
EVANS, SM ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (10) :857-881
[10]   ESTIMATION OF TUBULE OR CYLINDER LV, SV AND VV ON THICK SECTIONS [J].
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY-OXFORD, 1979, 117 (DEC) :333-345