Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification

被引:174
|
作者
Hamilton, Gavin [1 ]
Middleton, Michael S. [1 ]
Bydder, Mark [1 ]
Yokoo, Takeshi [1 ]
Schwimmer, Jeffrey B. [2 ]
Kono, Yuko [3 ]
Patton, Heather M. [3 ]
Lavine, Joel E. [2 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Div Gastroenterol Hepatol & Nutr, Dept Pediat, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Dept Med, San Diego, CA 92103 USA
关键词
liver fat quantification; magnetic resonance spectroscopy; PRESS; STEAM; IN-VIVO; PROTON SPECTROSCOPY; QUANTITATIVE-ANALYSIS; INSULIN-RESISTANCE; STIMULATED ECHOES; H-1; SPECTROSCOPY; MR SPECTROSCOPY; BRAIN MOTION; TRIGLYCERIDE; METABOLITES;
D O I
10.1002/jmri.21809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare PRESS and STEAM MR spectroscopy for assessment of liver fat in human subjects. Materials and Methods: Single-voxel (20 x 20 x 20 mm) PRESS and STEAM spectra were obtained at 1.5T in 49 human subjects with known or suspected fatty liver disease. PRESS and STEAM sequences were obtained with fixed TR (1500 msec) and different TE (five PRESS spectra between TE 30-70 msec, five STEAM spectra between TE 20-60 msec). Spectra were quantified and T2 and T2-corrected peak area were calculated by different techniques. The values were compared for PRESS and STEAM. Results: Water T2 values from PRESS and STEAM were not significantly different (P = 0.33). Fat peak T2s were 25%-50% shorter on PRESS than on STEAM (P < 0.02 for all comparisons) and there was no correlation between T2s of individual peaks. PRESS systematically overestimated the relative fat peak areas (by 7%-263%) compared to STEAM (P < 0.005 for all comparisons). The peak area given by PRESS was more dependent on the T2-correction technique than STEAM. Conclusion: Measured liver fat depends on the MRS sequence used. Compared to STEAM, PRESS underestimates T2 values of fat, overestimates fat fraction, and provides a less consistent fat fraction estimate, probably due to J coupling effects.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 50 条
  • [31] Accurate fat fraction quantification by multiecho gradient-recalled-echo magnetic resonance at 1.5 T in rats with nonalcoholic fatty liver disease
    Hijona, Elizabeth
    Sanchez-Gonzalez, Javier
    Alustiza, Jose M.
    Hijona, Lander
    Arenas, Juan
    Garcia, Elisabeth
    Rojas, Nohelia
    Portillo, Maria P.
    Jimenez, Raul
    Aldazabal, Pablo
    Bujanda, Luis
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (06) : 1122 - 1127
  • [32] Proton Magnetic Resonance Spectroscopic Findings of Cerebral Fat Embolism Induced by Triolein Emulsion in Cats
    Baik, S. K.
    Kim, Y-W
    Kim, H. J.
    Lee, J. W.
    Cho, B. M.
    Kim, D-H
    Choi, S. H.
    Lee, S. H.
    Chang, K. H.
    ACTA RADIOLOGICA, 2008, 49 (10) : 1174 - 1181
  • [33] In vivo 3T spectroscopic quantification of liver fat content in nonalcoholic fatty liver disease: Correlation with biochemical method and morphometry
    Roldan-Valadez, Ernesto
    Favila, Rafael
    Martinez-Lopez, Manuel
    Uribe, Misael
    Rios, Camilo
    Mendez-Sanchez, Nahum
    JOURNAL OF HEPATOLOGY, 2010, 53 (04) : 732 - 737
  • [34] Effect of Multipeak Spectral Modeling of Fat for Liver Iron and Fat Quantification: Correlation of Biopsy with MR Imaging Results
    Kuehn, Jens-Peter
    Hernando, Diego
    del Rio, Alejandro Munoz
    Evert, Matthias
    Kannengiesser, Stephan
    Voelzke, Henry
    Mensel, Birger
    Puls, Ralf
    Hosten, Norbert
    Reeder, Scott B.
    RADIOLOGY, 2012, 265 (01) : 133 - 142
  • [35] Body and liver fat content and adipokines in schizophrenia: a magnetic resonance imaging and spectroscopy study
    Kim, Jong-Hoon
    Kim, Jung-Hyun
    Park, Pil-Whan
    Machann, Juergen
    Roden, Michael
    Lee, Sheen-Woo
    Hwang, Jong-Hee
    PSYCHOPHARMACOLOGY, 2017, 234 (12) : 1923 - 1932
  • [36] Aspects of spinal bone marrow fat to water quantification with magnetic resonance spectroscopy at 3T
    Barber, Quinn M.
    Yahya, Atiyah
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [37] Validation of diffuse reflectance spectroscopy with magnetic resonance imaging for accurate vertebral bone fat fraction quantification
    Swamy, Akash
    Burstrom, Gustav
    Spliethoff, Jarich W.
    Babic, Drazenko
    Ruschke, Stefan
    Racadio, John M.
    Edstrom, Erik
    Terander, Adrian Elmi
    Dankelman, Jenny
    Hendriks, Benno H. W.
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (08) : 4316 - 4328
  • [38] Effect of a Low-Rank Denoising Algorithm on Quantitative Magnetic Resonance Imaging-Based Measures of Liver Fat and Iron
    Allen, Brian C.
    Lugauer, Felix
    Nickel, Dominik
    Bhatti, Lubna
    Dafalla, Randa A.
    Dale, Brian M.
    Jaffe, Tracy A.
    Bashir, Mustafa R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (03) : 412 - 416
  • [39] Accurate and simple method for quantification of hepatic fat content using magnetic resonance imaging: a prospective study in biopsy-proven nonalcoholic fatty liver disease
    Hatta, Tomoko
    Fujinaga, Yasunari
    Kadoya, Masumi
    Ueda, Hitoshi
    Murayama, Hiroaki
    Kurozumi, Masahiro
    Ueda, Kazuhiko
    Komatsu, Michiharu
    Nagaya, Tadanobu
    Joshita, Satoru
    Kodama, Ryo
    Tanaka, Eiji
    Uehara, Tsuyoshi
    Sano, Kenji
    Tanaka, Naoki
    JOURNAL OF GASTROENTEROLOGY, 2010, 45 (12) : 1263 - 1271
  • [40] Fat Quantification in the Vertebral Body: Comparison of Modified Dixon Technique with Single-Voxel Magnetic Resonance Spectroscopy
    Lee, Sang Hyup
    Yoo, Hye Jin
    Yu, Seung-Man
    Hong, Sung Hwan
    Choi, Ja-Young
    Chae, Hee Dong
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (01) : 126 - 133