Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification

被引:174
|
作者
Hamilton, Gavin [1 ]
Middleton, Michael S. [1 ]
Bydder, Mark [1 ]
Yokoo, Takeshi [1 ]
Schwimmer, Jeffrey B. [2 ]
Kono, Yuko [3 ]
Patton, Heather M. [3 ]
Lavine, Joel E. [2 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Div Gastroenterol Hepatol & Nutr, Dept Pediat, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Dept Med, San Diego, CA 92103 USA
关键词
liver fat quantification; magnetic resonance spectroscopy; PRESS; STEAM; IN-VIVO; PROTON SPECTROSCOPY; QUANTITATIVE-ANALYSIS; INSULIN-RESISTANCE; STIMULATED ECHOES; H-1; SPECTROSCOPY; MR SPECTROSCOPY; BRAIN MOTION; TRIGLYCERIDE; METABOLITES;
D O I
10.1002/jmri.21809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare PRESS and STEAM MR spectroscopy for assessment of liver fat in human subjects. Materials and Methods: Single-voxel (20 x 20 x 20 mm) PRESS and STEAM spectra were obtained at 1.5T in 49 human subjects with known or suspected fatty liver disease. PRESS and STEAM sequences were obtained with fixed TR (1500 msec) and different TE (five PRESS spectra between TE 30-70 msec, five STEAM spectra between TE 20-60 msec). Spectra were quantified and T2 and T2-corrected peak area were calculated by different techniques. The values were compared for PRESS and STEAM. Results: Water T2 values from PRESS and STEAM were not significantly different (P = 0.33). Fat peak T2s were 25%-50% shorter on PRESS than on STEAM (P < 0.02 for all comparisons) and there was no correlation between T2s of individual peaks. PRESS systematically overestimated the relative fat peak areas (by 7%-263%) compared to STEAM (P < 0.005 for all comparisons). The peak area given by PRESS was more dependent on the T2-correction technique than STEAM. Conclusion: Measured liver fat depends on the MRS sequence used. Compared to STEAM, PRESS underestimates T2 values of fat, overestimates fat fraction, and provides a less consistent fat fraction estimate, probably due to J coupling effects.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 50 条
  • [21] Spatio-spectral regularization to improve magnetic resonance spectroscopic imaging quantification
    Laruelo, Andrea
    Chaari, Lotfi
    Tourneret, Jean-Yves
    Batatia, Hadj
    Ken, Soleakhena
    Rowland, Ben
    Ferrand, Regis
    Laprie, Anne
    NMR IN BIOMEDICINE, 2016, 29 (07) : 918 - 931
  • [22] Non-invasive assessment and quantification of liver steatosis by ultrasound, computed tomography and magnetic resonance
    Schwenzer, Nina F.
    Springer, Fabian
    Schraml, Christina
    Stefan, Norbert
    Machann, Juergen
    Schick, Fritz
    JOURNAL OF HEPATOLOGY, 2009, 51 (03) : 433 - 445
  • [23] 3.0 T proton magnetic resonance spectroscopy of the liver: Quantification of choline
    Li Xu
    Bo Liu
    Yan Huang
    Xian Liu
    Si-Wei Zhang
    Xue-Gang Xin
    Ji-Zhi Zheng
    World Journal of Gastroenterology, 2013, (09) : 1472 - 1477
  • [24] Hepatic fat quantification magnetic resonance for monitoring treatment response in pediatric nonalcoholic steatohepatitis
    Koh, Hong
    Kim, Seung
    Kim, Myung-Joon
    Kim, Hyun Gi
    Shin, Hyun Joo
    Lee, Mi-Jung
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (33) : 9741 - 9748
  • [25] Quantification by the fast Pad, transform of magnetic resonance spectroscopic data encoded at 1.5 T: implications for brain tumor diagnostics
    Belkic, Dzevad
    Belkic, Karen
    JOURNAL OF MATHEMATICAL CHEMISTRY, 2016, 54 (02) : 602 - 655
  • [26] Hepatic Fat Quantification A Prospective Comparison of Magnetic Resonance Spectroscopy and Analysis Methods for Chemical-Shift Gradient Echo Magnetic Resonance Imaging With Histologic Assessment as the Reference Standard
    Kang, Bo-Kyeong
    Yu, Eun Sil
    Lee, Seung Soo
    Lee, Youngjoo
    Kim, Namkug
    Sirlin, Claude B.
    Cho, Eun Yoon
    Yeom, Suk Keu
    Byun, Jae Ho
    Park, Seong Ho
    Lee, Moon-Gyu
    INVESTIGATIVE RADIOLOGY, 2012, 47 (06) : 368 - 375
  • [27] Comparison of Accuracy of Magnetic Resonance Spectroscopic and Imaging Techniques for the Liver Steatosis Assessment
    Sedivy, Petr
    Dezortova, Monika
    Burian, Martin
    Dusilova, Tereza
    Kovar, Jan
    Hajek, Milan
    CHEMICKE LISTY, 2021, 115 (01): : 46 - 53
  • [28] Marked difference in liver fat measured by histology vs. magnetic resonance-proton density fat fraction: A meta analysis
    Qadri, Sami
    Vartiainen, Emilia
    Lahelma, Mari
    Porthan, Kimmo
    Tang, An
    Idilman, Ilkay S.
    Runge, Jurgen H.
    Juuti, Anne
    Penttila, Anne K.
    Dabek, Juhani
    Lehtimaki, Tiina E.
    Seppaenen, Wenla
    Arola, Johanna
    Arkkila, Perttu
    Stoker, Jaap
    Karcaaltincaba, Musturay
    Pavlides, Michael
    Loomba, Rohit
    Sirlin, Claude B.
    Tukiainen, Taru
    Yki-Jarvinen, Hannele
    JHEP REPORTS, 2024, 6 (01)
  • [29] Three-dimensional high-resolution magnetic resonance spectroscopic imaging for absolute quantification of 31P metabolites in human liver
    Chmelik, M.
    Schmid, A. I.
    Gruber, S.
    Szendroedi, J.
    Krssak, M.
    Trattnig, S.
    Moser, E.
    Roden, M.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (04) : 796 - 802