Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification

被引:174
|
作者
Hamilton, Gavin [1 ]
Middleton, Michael S. [1 ]
Bydder, Mark [1 ]
Yokoo, Takeshi [1 ]
Schwimmer, Jeffrey B. [2 ]
Kono, Yuko [3 ]
Patton, Heather M. [3 ]
Lavine, Joel E. [2 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Div Gastroenterol Hepatol & Nutr, Dept Pediat, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Dept Med, San Diego, CA 92103 USA
关键词
liver fat quantification; magnetic resonance spectroscopy; PRESS; STEAM; IN-VIVO; PROTON SPECTROSCOPY; QUANTITATIVE-ANALYSIS; INSULIN-RESISTANCE; STIMULATED ECHOES; H-1; SPECTROSCOPY; MR SPECTROSCOPY; BRAIN MOTION; TRIGLYCERIDE; METABOLITES;
D O I
10.1002/jmri.21809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare PRESS and STEAM MR spectroscopy for assessment of liver fat in human subjects. Materials and Methods: Single-voxel (20 x 20 x 20 mm) PRESS and STEAM spectra were obtained at 1.5T in 49 human subjects with known or suspected fatty liver disease. PRESS and STEAM sequences were obtained with fixed TR (1500 msec) and different TE (five PRESS spectra between TE 30-70 msec, five STEAM spectra between TE 20-60 msec). Spectra were quantified and T2 and T2-corrected peak area were calculated by different techniques. The values were compared for PRESS and STEAM. Results: Water T2 values from PRESS and STEAM were not significantly different (P = 0.33). Fat peak T2s were 25%-50% shorter on PRESS than on STEAM (P < 0.02 for all comparisons) and there was no correlation between T2s of individual peaks. PRESS systematically overestimated the relative fat peak areas (by 7%-263%) compared to STEAM (P < 0.005 for all comparisons). The peak area given by PRESS was more dependent on the T2-correction technique than STEAM. Conclusion: Measured liver fat depends on the MRS sequence used. Compared to STEAM, PRESS underestimates T2 values of fat, overestimates fat fraction, and provides a less consistent fat fraction estimate, probably due to J coupling effects.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 50 条
  • [1] QUANTIFICATION OF LIVER FAT USING MAGNETIC-RESONANCE SPECTROSCOPY
    THOMSEN, C
    BECKER, U
    WINKLER, K
    CHRISTOFFERSEN, P
    JENSEN, M
    HENRIKSEN, O
    MAGNETIC RESONANCE IMAGING, 1994, 12 (03) : 487 - 495
  • [2] Comparison of magnetic resonance spectroscopy, proton density fat fraction and histological analysis in the quantification of liver steatosis in children and adolescents
    Di Martino, Michele
    Pacifico, Lucia
    Bezzi, Mario
    Di Miscio, Rossella
    Sacconi, Beatrice
    Chiesa, Claudio
    Catalano, Carlo
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (39) : 8812 - 8819
  • [3] Magnetic Resonance Techniques for Fat Quantification in Obesity
    Hu, Houchun Harry
    2012 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA ASC), 2012,
  • [4] A Novel Portable Unilateral Magnetic Resonance Magnet for Noninvasive Quantification of Human Liver Fat
    Lu, Rongsheng
    Jiang, Xiaowen
    Zhang, Jinxiang
    Hu, Jianxiong
    Chen, Xiao
    Wu, Ziyue
    Qian, Zhiyong
    Luo, Hai
    Ni, Zhonghua
    Yi, Hong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [5] Evaluating Childhood Obesity: Magnetic Resonance-Based Quantification of Abdominal Adipose Tissue and Liver Fat in Children
    Raschpichler, M. C.
    Sorge, I.
    Hirsch, W.
    Mende, M.
    Sergeyev, E.
    Kruber, D.
    Koerner, A.
    Schick, F.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (04): : 324 - 332
  • [6] Reproducibility of in vivo metabolite quantification with proton magnetic resonance spectroscopic Imaging
    Chard, DT
    McLean, MA
    Parker, GJM
    MacManus, DG
    Miller, DH
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (02) : 219 - 225
  • [7] Quantification of Hepatic Fat and Iron with Magnetic Resonance Imaging
    Wells, Shane A.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2014, 22 (03) : 397 - +
  • [8] Non-invasive quantification of hepatic fat content in healthy dogs by using proton magnetic resonance spectroscopy and dual gradient echo magnetic resonance imaging
    Del Chicca, Francesca
    Schwarz, Andrea
    Meier, Dieter
    Grest, Paula
    Liesegang, Annette
    Kircher, Patrick R.
    JOURNAL OF VETERINARY SCIENCE, 2018, 19 (04) : 570 - 576
  • [9] 3.0 T proton magnetic resonance spectroscopy of the liver: Quantification of choline
    Xu, Li
    Liu, Bo
    Huang, Yan
    Liu, Xian
    Zhang, Si-Wei
    Xin, Xue-Gang
    Zheng, Jin-Zhi
    WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (09) : 1472 - 1477
  • [10] Metabolite Absolute Quantification in Rabbit liver by Proton Magnetic Resonance Spectroscopy
    Shen, Zhiwei
    You, Kezeng
    Yang, Zhongxian
    Chen, Yaowen
    Wu, Renhua
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 947 - 950