Influence of optical properties on two-photon fluorescence imaging in turbid samples

被引:159
作者
Dunn, AK [1 ]
Wallace, VP [1 ]
Coleno, M [1 ]
Berns, MW [1 ]
Tromberg, BJ [1 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Laser Med & Microbeam Program, Irvine, CA 92612 USA
关键词
D O I
10.1364/AO.39.001194
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A numerical model was developed to simulate the effects of tissue optical properties, objective numerical aperture (N.A.), and instrument performance on two-photon-excited fluorescence imaging of turbid samples. Model data are compared with measurements of fluorescent microspheres in a tissuelike scattering phantom. Our results show that the measured two-photon-excited signal decays exponentially with increasing focal depth. The overall decay constant is a function of absorption and scattering parameters at both excitation and emission wavelengths. The generation of two-photon fluorescence is shown to be independent of the scattering anisotropy, g, except for g > 0.95. The N.A. for which the maximum signal is collected varies with depth, although this effect is not seen until the focal plane is greater than two scattering mean free paths into the sample. Overall, measurements and model results indicate that resolution in two-photon microscopy is dependent solely on the ability to deliver sufficient ballistic photon density to the focal volume. As a result we show that lateral resolution in two-photon microscopy is largely unaffected by tissue optical properties in the range typically encountered in soft tissues, although the maximum imaging depth is strongly dependent on absorption and scattering coefficients, scattering anisotropy, and objective N.A.. (C) 2000 Optical Society of America.
引用
收藏
页码:1194 / 1201
页数:8
相关论文
共 21 条
  • [1] Multiphoton excitation provides optical sections from deeper within scattering specimens than confocal imaging
    Centonze, VE
    White, JG
    [J]. BIOPHYSICAL JOURNAL, 1998, 75 (04) : 2015 - 2024
  • [2] 2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY
    DENK, W
    STRICKLER, JH
    WEBB, WW
    [J]. SCIENCE, 1990, 248 (4951) : 73 - 76
  • [3] Three-dimensional computation of light scattering from cells
    Dunn, A
    RichardsKortum, R
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) : 898 - 905
  • [4] Sources of contrast in confocal reflectance imaging
    Dunn, AK
    Smithpeter, C
    Welch, AJ
    RichardsKortum, R
    [J]. APPLIED OPTICS, 1996, 35 (19) : 3441 - 3446
  • [5] Farrell TJ, 1998, PHOTOCHEM PHOTOBIOL, V68, P394, DOI 10.1562/0031-8655(1998)068<0394:COTVPT>2.3.CO
  • [6] 2
  • [7] Frequency-domain photon migration measurements of normal and malignant tissue optical properties in a human subject
    Fishkin, JB
    Coquoz, O
    Anderson, ER
    Brenner, M
    Tromberg, BJ
    [J]. APPLIED OPTICS, 1997, 36 (01) : 10 - 20
  • [8] Image formation in turbid media under a microscope
    Gan, XS
    Schilders, SP
    Gu, M
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (08): : 2052 - 2058
  • [9] Effective point-spread function for fast image modeling and processing in microscopic imaging through turbid media
    Gan, XS
    Gu, M
    [J]. OPTICS LETTERS, 1999, 24 (11) : 741 - 743
  • [10] Quantitative near-infrared spectroscopy of cervical dysplasia in vivo
    Hornung, R
    Pham, TH
    Keefe, KA
    Berns, MW
    Tadir, Y
    Tromberg, BJ
    [J]. HUMAN REPRODUCTION, 1999, 14 (11) : 2908 - 2916