Modeling and Analysis of a Microresonating Biosensor for Detection of Salmonella Bacteria in Human Blood

被引:37
作者
Bahadoran, Mahdi [1 ]
Noorden, Ahmad Fakhrurrazi Ahmad [1 ]
Chaudhary, Kashif [1 ]
Mohajer, Faeze Sadat [2 ]
Aziz, Muhammad Safwan [1 ]
Hashim, Shahrin [3 ]
Ali, Jalil [1 ]
Yupapin, Preecha [4 ]
机构
[1] UTM, Nanotechnol Res Alliance, Inst Adv Photon Sci, Johor Baharu 81310, Malaysia
[2] UTM, Bioinformat Res Grp, Johor Baharu 81310, Malaysia
[3] UTM, Econ Res Alliance RAKE K, Johor Baharu 81310, Malaysia
[4] King Mongkuts Inst Technol Ladkrabang, Fac Sci, Adv Photon Res Ctr, Bangkok 10520, Thailand
关键词
nonlinear optics; microring resonator; biophotonics; biosensor; Salmonella bacteria; SILICON-ON-INSULATOR; RING-RESONATORS; MICRORING RESONATORS; SENSOR; FLAGELLIN; OPTICS;
D O I
10.3390/s140712885
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new photonics biosensor configuration comprising a Double-side Ring Add-drop Filter microring resonator (DR-ADF) made from SiO2-TiO2 material is proposed for the detection of Salmonella bacteria (SB) in blood. The scattering matrix method using inductive calculation is used to determine the output signal's intensities in the blood with and without presence of Salmonella. The change in refractive index due to the reaction of Salmonella bacteria with its applied antibody on the flagellin layer loaded on the sensing and detecting microresonator causes the increase in through and dropper port's intensities of the output signal which leads to the detection of SB in blood. A shift in the output signal wavelength is observed with resolution of 0.01 nm. The change in intensity and shift in wavelength is analyzed with respect to the change in the refractive index which contributes toward achieving an ultra-high sensitivity of 95,500 nm/RIU which is almost two orders higher than that of reported from single ring sensors and the limit of detection is in the order of 1 x 10(-8) RIU. In applications, such a system can be employed for a high sensitive and fast detection of bacteria.
引用
收藏
页码:12885 / 12899
页数:15
相关论文
共 50 条
[31]   Dielectric modulated organic thin film transistor trench biosensor for label-free detection: Modeling and simulation analysis [J].
Bhandari, Sheetal ;
Dhamale, Triveni D. ;
Kawade, Rupali K. ;
Dhake, Dipali N. ;
Wadhwa, Girish .
INTERNATIONAL JOURNAL OF NUMERICAL MODELLING-ELECTRONIC NETWORKS DEVICES AND FIELDS, 2024, 37 (02)
[32]   Label-free detection of glycated haemoglobin in human blood using silicon-based photonic crystal nanocavity biosensor [J].
Olyaee, Saeed ;
Seifouri, Mahmood ;
Mohsenirad, Hamideh .
JOURNAL OF MODERN OPTICS, 2016, 63 (13) :1274-1279
[33]   A simple nanostructured biosensor based on clavanin A antimicrobial peptide for gram-negative bacteria detection [J].
de Miranda, Juliana L. ;
Oliveira, Maria D. L. ;
Oliveira, Idjane S. ;
Frias, Isaac A. M. ;
Franco, Octavio L. ;
Andrade, Cesar A. S. .
BIOCHEMICAL ENGINEERING JOURNAL, 2017, 124 :108-114
[34]   Ultrahigh sensitivity fiber laser integrated biosensor for TNF-α detection in human blood sample [J].
Cao, Haoyuan ;
Liu, Jiandong ;
Wei, Dandan ;
Liu, Bin ;
Hu, Yingying ;
Liu, Juan ;
Wan, Shengpeng ;
Wu, Tao ;
He, Xing-Dao ;
Jiang, Jun ;
Xu, Hengyi ;
Farrell, Gerald ;
Wu, Qiang .
SENSORS AND ACTUATORS B-CHEMICAL, 2025, 422
[35]   A Flexible Near-Field Biosensor for Multisite Arterial Blood Flow Detection [J].
Mohammed, Noor ;
Cluff, Kim ;
Sutton, Mark ;
Villafana-Ibarra, Bernardo ;
Loflin, Benjamin E. ;
Griffith, Jacob L. ;
Becker, Ryan ;
Bhandari, Subash ;
Alruwaili, Fayez ;
Desai, Jaydip .
SENSORS, 2022, 22 (21)
[36]   A microfluidic biosensor for rapid detection of Salmonella typhimurium based on magnetic separation, enzymatic catalysis and electrochemical impedance analysis [J].
Liu, Yingjia ;
Jiang, Dong ;
Wang, Siyuan ;
Cai, Gaozhe ;
Xue, Li ;
Li, Yanbin ;
Liao, Ming ;
Lin, Jianhan .
CHINESE CHEMICAL LETTERS, 2022, 33 (06) :3156-3160
[37]   Computational modeling of amperometric choline biosensor for neurochemical detection [J].
Ravikumar, P. ;
Arumugam, S. ;
Jeyashanthi, N. .
BIOMEDICAL RESEARCH-INDIA, 2016, 27 (04) :1271-1274
[38]   Characterization of nanoporous silicon-based DNA biosensor for the detection of Salmonella Enteritidis [J].
Zhang, Deng ;
Alocilja, Evangelyn C. .
IEEE SENSORS JOURNAL, 2008, 8 (5-6) :775-780
[39]   Effect of III-V nitrides on performance of graphene based SPR biosensor for detection of hemoglobin in human blood sample: A comparative analysis [J].
Mohanty, Goutam ;
Sahoo, Bijaya Ku .
CURRENT APPLIED PHYSICS, 2016, 16 (12) :1607-1613
[40]   Label-free visual biosensor based on cascade amplification for the detection of Salmonella [J].
Zhang, Yuan ;
Tian, Jingjing ;
Li, Kai ;
Tian, Hongtao ;
Xu, Wentao .
ANALYTICA CHIMICA ACTA, 2019, 1075 :144-151