Objectives-Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent probe positioning and image interpretation. Methods-The medial gastrocnemius muscle of 15 healthy participants was measured with sagittal B-mode ultrasound scans. The muscle thickness, fascicle length, superior pennation angle, and inferior pennation angle were assessed. The participants were examined by 2 investigators. A custom-made foam cast was used for standardized positioning of the probe. To analyze inter-rater reliability, the examinations of both raters were compared. The impact of probe positioning was assessed by comparison of foam cast and freehand scans. Error arising from picture interpretation was assessed by comparing the investigators' analyses of foam cast scans independently. Reliability was expressed as the intradass correlation coefficient (ICC), inter-rater variability (IRV), Bland-Altman analysis (bias +/- limits of agreement [LoA]), and standard error of measurement (SEM). Results-Inter-rater reliability was good overall (ICC, 0.77-0.90; IRV, 9.0%-13.4%; bias LoA, 0.2 +/- 0.2-1.7 +/- 3.0). Superior and inferior pennation angles showed high systematic bias and LoA in all setups, ranging from 2.0 degrees +/- 2.2 degrees to 3.4 degrees +/- 4.1 degrees. The highest IRV was found for muscle thickness (13.4%). "When the probe position was standardized, the SEM for muscle thickness decreased from 0.1 to 0.05 cm. Conclusions-Sonographic examination of muscle architecture of the medial gastrocnemius has good to high reliability. In contrast to pennation angle measurements, length measurements can be improved by standardization of the probe position.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 50 条
  • [31] Reliability of a semi-automated algorithm for the vastus lateralis muscle architecture measurement based on ultrasound images
    Marzilger, Robert
    Legerlotz, Kirsten
    Panteli, Chrystalla
    Bohm, Sebastian
    Arampatzis, Adamantios
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2018, 118 (02) : 291 - 301
  • [32] Inter-rater and intra-rater reliability of isotonic exercise monitoring device for measuring active knee extension
    Limsakul, Chonnanid
    Sengchuai, Kiattisak
    Duangsoithong, Rakkrit
    Jindapetch, Nattha
    Jaruenpunyasak, Jermphiphut
    PEERJ, 2023, 11
  • [33] Intra- and Inter-Rater Reliability, Measurement Error and Criteria and Convergent Validities of the Dualpex Plus for the Vaginal Manometry of Pelvic Floor Muscles in Women With Urinary Incontinence
    Carro, Daniela Fantin
    da Silveira, Leda Tomiko Yamada
    Baracat, Edmund Chada
    Haddad, Jorge
    Lunardi, Adriana C.
    Ferreira, Elizabeth Alves
    NEUROUROLOGY AND URODYNAMICS, 2025, 44 (02) : 416 - 423
  • [34] Enhancing Trigger Point Dry Needling Safety by Ultrasound Skin-to-Rib Measurement: An inter-Rater Reliability Study
    Folli, Anna
    Schneebeli, Alessandro
    Ballerini, Simone
    Mena, Francesca
    Soldini, Emiliano
    Fernandez-de-las-Penas, Cesar
    Barbero, Marco
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (06) : 1 - 10
  • [35] Morphometry of thenar muscles by water bath ultrasonography in trapeziometacarpal osteoarthritis: intra- and inter-rater reliability
    Karademir, Feray
    Kuru, Cigdem Ayhan
    Arin, Gamze
    Soylu, Ruhi
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (02) : 115 - 122
  • [36] Tele-Assessment of Functional Capacity: Validity, Intra- and Inter-rater Reliability
    Asliyüce, Yasemin Ozel
    Fanuscu, Aybuke
    Asliyüce, Abdurahim
    Ülger, Ozlem
    WORKPLACE HEALTH & SAFETY, 2023, 71 (10) : 476 - 483
  • [37] Inter-rater reliability of a classification system for athletes with intellectual disabilities in adapted judo competitions
    Morales, Jose
    Garcia, Vanessa
    Fukuda, David H.
    Pierantozzi, Emanuela
    Mulroy, James
    Martinez-Ferrer, Josep O.
    Guerra-Balic, Myriam
    ARCHIVES OF BUDO, 2021, 17 : 119 - 125
  • [38] Evaluation of the Lower Trapezius Muscle Using Ultrasound Panoramic View (a Novel Approach): An Intra- and Inter-Rater Reliability Study
    Fernandez-Carnero, Samuel
    Garrido-Marin, Alejandro
    Achalandabaso-Ochoa, Alexander
    Ferragut-Garcias, Alejandro
    Fernandez-Matias, Ruben
    Pecos-Martin, Daniel
    Gallego-Izquierdo, Tomas
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (19) : 1 - 10
  • [39] Inter-rater reliability of the Rasch-modified medical research council scoring criteria for manual muscle testing in neuromuscular diseases
    Conde, Rodrigo Melo
    Pena, Livia de Almeida Pereira
    Elias, Adriana Helenado Nascimento
    Guerreiro, Carlos Tostes
    Pereira, Danilo Assis
    Sobreira, Claudia Ferreira da Rosa
    Marques, Wilson
    Barreira, Amilton Antunes
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2023, 28 (01) : 119 - 124
  • [40] Ultrasound imaging in patients with hip pain and suspected hip osteoarthritis: an inter-rater and intra-rater reliability study
    Clausen, Stine
    Kjaer, Soren
    Fredberg, Ulrich
    Terslev, Lene
    Hartvigsen, Jan
    Arnbak, Bodil
    BMJ OPEN, 2020, 10 (11):