Inter-Rater Reliability and Measurement Error of Sonographic Muscle Architecture Assessments

被引:35
|
作者
Koenig, Niklas [1 ]
Cassel, Michael [1 ]
Intziegianni, Konstantina [1 ]
Mayer, Frank [1 ]
机构
[1] Univ Potsdam, Univ Outpatient Clin, D-14469 Potsdam, Germany
关键词
gastrocnemius muscle; inter-rater variability; muscle architecture; musculoskeletal ultrasound; sonography; TRAINING-INDUCED CHANGES; GASTROCNEMIUS MEDIALIS; VASTUS LATERALIS; PENNATION ANGLE; ULTRASOUND; STRENGTH; TENDON; CONTRACTION; ADAPTATIONS; FORCE;
D O I
10.7863/ultra.33.5.769
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent probe positioning and image interpretation. Methods-The medial gastrocnemius muscle of 15 healthy participants was measured with sagittal B-mode ultrasound scans. The muscle thickness, fascicle length, superior pennation angle, and inferior pennation angle were assessed. The participants were examined by 2 investigators. A custom-made foam cast was used for standardized positioning of the probe. To analyze inter-rater reliability, the examinations of both raters were compared. The impact of probe positioning was assessed by comparison of foam cast and freehand scans. Error arising from picture interpretation was assessed by comparing the investigators' analyses of foam cast scans independently. Reliability was expressed as the intradass correlation coefficient (ICC), inter-rater variability (IRV), Bland-Altman analysis (bias +/- limits of agreement [LoA]), and standard error of measurement (SEM). Results-Inter-rater reliability was good overall (ICC, 0.77-0.90; IRV, 9.0%-13.4%; bias LoA, 0.2 +/- 0.2-1.7 +/- 3.0). Superior and inferior pennation angles showed high systematic bias and LoA in all setups, ranging from 2.0 degrees +/- 2.2 degrees to 3.4 degrees +/- 4.1 degrees. The highest IRV was found for muscle thickness (13.4%). "When the probe position was standardized, the SEM for muscle thickness decreased from 0.1 to 0.05 cm. Conclusions-Sonographic examination of muscle architecture of the medial gastrocnemius has good to high reliability. In contrast to pennation angle measurements, length measurements can be improved by standardization of the probe position.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 50 条
  • [21] Reliability of ultrasonographic measurement of muscle architecture of the gastrocnemius medialis and gastrocnemius lateralis
    May, Samantha
    Locke, Simon
    Kingsley, Michael
    PLOS ONE, 2021, 16 (09):
  • [22] The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain
    Juul, Tina
    Langberg, Henning
    Enoch, Flemming
    Sogaard, Karen
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [23] Intra- and inter-rater reliability for analysis of hyoid displacement measured with sonography
    Macrae, Phoebe R.
    Doeltgen, Sebastian H.
    Jones, Richard D.
    Huckabee, Maggie-Lee
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (02) : 74 - 78
  • [24] Intra-rater reliability, inter-rater reliability and minimal detectable change of the posterior shoulder endurance test in elite athletes
    Powell, Andrew
    Levy, Emma
    Heneghan, Nicola R.
    Horsley, Ian
    PHYSICAL THERAPY IN SPORT, 2021, 49 : 62 - 67
  • [25] Ultrasound Examination of the Median Nerve at Different Levels: Inter-rater Reliability Study
    Dede, Burak Tayyip
    Kilinc, Fatih
    Oguz, Muhammed
    Bagcier, Fatih
    Aytekin, Ebru
    TURK OSTEOPOROZ DERGISI-TURKISH JOURNAL OF OSTEOPOROSIS, 2024, 30 (01): : 44 - 48
  • [26] Inter-rater reliability study of the modified Oxford Grading Scale and the Peritron manometer
    Jorge Ferreira, Cristine Homsi
    Barbosa, Patricia Brentegani
    Souza, Flaviane de Oliveira
    Antonio, Flavia Ignacio
    Franco, Maira Menezes
    Bo, Kari
    PHYSIOTHERAPY, 2011, 97 (02) : 132 - 138
  • [27] Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament
    Zachary A. Sievert
    Hunter J. Bennett
    Joshua T. Weinhandl
    Journal of Ultrasound, 2021, 24 : 49 - 55
  • [28] Physiotherapist inter-rater reliability of the Haemophilia Early Arthropathy Detection with Ultrasound protocol
    Stephensen, D.
    Classey, S.
    Harbidge, H.
    Patel, V.
    Taylor, S.
    Wells, A.
    HAEMOPHILIA, 2018, 24 (03) : 471 - 476
  • [29] Inter-Rater Reliability of Ultrasound Imaging of the Trunk Musculature Among Novice Raters
    Teyhen, Deydre S.
    George, Steven Z.
    Dugan, Jessica L.
    Williamson, Jared
    Neilson, Brett D.
    Childs, John D.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (03) : 347 - 356
  • [30] INTER-RATER RELIABILITY OF THE DIGITAL PALPATION OF PELVIC FLOOR MUSCLE BY THE MODIFIED OXFORD GRADING SCALE IN CONTINENT AND INCONTINENT WOMEN
    Romero-Culleres, Georgia
    Jane-Feixasi, Cecilia
    Vilaseca-Grane, Anna
    Arnau, Anna
    Montesinos, Jesus
    Abenoza-Guardiola, Montserrat