Inter-Rater Reliability and Measurement Error of Sonographic Muscle Architecture Assessments

被引:35
|
作者
Koenig, Niklas [1 ]
Cassel, Michael [1 ]
Intziegianni, Konstantina [1 ]
Mayer, Frank [1 ]
机构
[1] Univ Potsdam, Univ Outpatient Clin, D-14469 Potsdam, Germany
关键词
gastrocnemius muscle; inter-rater variability; muscle architecture; musculoskeletal ultrasound; sonography; TRAINING-INDUCED CHANGES; GASTROCNEMIUS MEDIALIS; VASTUS LATERALIS; PENNATION ANGLE; ULTRASOUND; STRENGTH; TENDON; CONTRACTION; ADAPTATIONS; FORCE;
D O I
10.7863/ultra.33.5.769
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent probe positioning and image interpretation. Methods-The medial gastrocnemius muscle of 15 healthy participants was measured with sagittal B-mode ultrasound scans. The muscle thickness, fascicle length, superior pennation angle, and inferior pennation angle were assessed. The participants were examined by 2 investigators. A custom-made foam cast was used for standardized positioning of the probe. To analyze inter-rater reliability, the examinations of both raters were compared. The impact of probe positioning was assessed by comparison of foam cast and freehand scans. Error arising from picture interpretation was assessed by comparing the investigators' analyses of foam cast scans independently. Reliability was expressed as the intradass correlation coefficient (ICC), inter-rater variability (IRV), Bland-Altman analysis (bias +/- limits of agreement [LoA]), and standard error of measurement (SEM). Results-Inter-rater reliability was good overall (ICC, 0.77-0.90; IRV, 9.0%-13.4%; bias LoA, 0.2 +/- 0.2-1.7 +/- 3.0). Superior and inferior pennation angles showed high systematic bias and LoA in all setups, ranging from 2.0 degrees +/- 2.2 degrees to 3.4 degrees +/- 4.1 degrees. The highest IRV was found for muscle thickness (13.4%). "When the probe position was standardized, the SEM for muscle thickness decreased from 0.1 to 0.05 cm. Conclusions-Sonographic examination of muscle architecture of the medial gastrocnemius has good to high reliability. In contrast to pennation angle measurements, length measurements can be improved by standardization of the probe position.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 50 条
  • [1] Intra- and inter-rater reliability of jumping mechanography muscle function assessments
    Matheson, L. A.
    Duffy, S.
    Maroof, A.
    Gibbons, R.
    Duffy, C.
    Roth, J.
    JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS, 2013, 13 (04) : 480 - 486
  • [2] INTER-RATER RELIABILITY OF SONOGRAPHIC MEASUREMENTS OF THE INFERIOR VENA CAVA
    Saul, Turandot
    Lewiss, Resa E.
    Langsfeld, Alexis
    Radeos, Michael S.
    Del Rios, Marina
    JOURNAL OF EMERGENCY MEDICINE, 2012, 42 (05) : 600 - 605
  • [3] Inter-rater reliability for noninvasive measurement of cardiac function in children
    Stewart, Gail M.
    Nguyen, H. Bryant
    Kim, Tommy Y.
    Jauregui, Joshua
    Hayes, Sean R.
    Corbett, Stephen
    PEDIATRIC EMERGENCY CARE, 2008, 24 (07) : 433 - 437
  • [4] Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
    Martinho, Natalia M.
    Marques, Joseane
    Silva, Valeria R.
    Silva, Silvia L. A.
    Carvalho, Leonardo C.
    Botelho, Simone
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2015, 19 (02) : 97 - 104
  • [5] AN INTRA -AND INTER-RATER RELIABILITY STUDY OF THE MEASUREMENT OF PELVIC FLOOR MUSCLE FUNCTION USING MANOMETRY.
    Tennfjord, M.
    Hilde, G.
    Ellstrom-Engh, M.
    Bo, K.
    NEUROUROLOGY AND URODYNAMICS, 2016, 35 : S459 - S460
  • [6] Inter-rater reliability of the GNRBO® knee arthrometer
    Vauhnik, Renata
    Morrissey, Matthew C.
    Perme, Maja Pohar
    Sevsek, France
    Rugelj, Darja
    KNEE, 2014, 21 (02) : 541 - 543
  • [7] Intra-session and inter-rater reliability of spatial frequency analysis methods in skeletal muscle
    Crawford, Scott K.
    Lee, Kenneth S.
    Bashford, Greg R.
    Heiderscheit, Bryan C.
    PLOS ONE, 2020, 15 (07):
  • [8] Inter-rater reliability and variability of ultrasound measurements of abdominal muscles and fasciae thickness
    Pirri, Carmelo
    Todros, Silvia
    Fede, Caterina
    Pianigiani, Silvia
    Fan, Chenglei
    Foti, Calogero
    Stecco, Carla
    Pavan, Piero
    CLINICAL ANATOMY, 2019, 32 (07) : 948 - 960
  • [9] Intra- and inter-rater reliabilities of measurement of ultrasound imaging for muscle thickness and pennation angle of tibialis anterior muscle in stroke patients
    Cho, Ki Hun
    Lee, Hwang Jae
    Lee, Wan Hee
    TOPICS IN STROKE REHABILITATION, 2017, 24 (05) : 368 - 373
  • [10] Inter-rater and intra-rater reliability of the airway diameter measured by sonography
    Gómez-Tamayo J.C.
    Puerta-Guarín J.I.
    Rojas-Camejo C.M.
    Caicedo J.P.
    Calvache J.A.
    Journal of Ultrasound, 2018, 21 (1) : 35 - 40