CTER Rapid estimation of CTF parameters with error assessment

被引:51
作者
Penczek, Pawel A. [1 ]
Fang, Jia [1 ]
Li, Xueming [2 ]
Cheng, Yifan [2 ]
Loerke, Justus [3 ]
Spahn, Christian M. T. [3 ]
机构
[1] Univ Texas Houston, Sch Med, Dept Biochem & Mol Biol, Houston, TX 77054 USA
[2] Univ Calif San Francisco, Dept Biochem & Biophys, Keck Adv Microscopy Lab, San Francisco, CA 94158 USA
[3] Charite, Inst Med Phys & Biophys, D-10117 Berlin, Germany
基金
美国国家卫生研究院;
关键词
Electron microscopy; Contrast transfer function; Error estimation; TRANSMISSION ELECTRON-MICROSCOPY; CONTRAST TRANSFER-FUNCTION; DIRECT-DETECTION DEVICE; EMBEDDED SINGLE PARTICLES; BEAM-INDUCED MOTION; POWER SPECTRA; 3-DIMENSIONAL RECONSTRUCTION; CRYO-EM; CRYOELECTRON MICROSCOPY; ACCURATE DETERMINATION;
D O I
10.1016/j.ultramic.2014.01.009
中图分类号
TH742 [显微镜];
学科分类号
摘要
In structural electron microscopy, the accurate estimation of the Contrast Transfer Function (CTF) parameters, particularly defocus and astigmatism, is of utmost importance for both initial evaluation of micrograph quality and for subsequent structure determination. Due to increases in the rate of data collection on modern microscopes equipped with new generation cameras, it is also important that the CTF estimation can be done rapidly and with minimal user intervention. Finally, in order to minimize the necessity for manual screening of the micrographs by a user it is necessary to provide an assessment of the errors of fitted parameters values. In this work we introduce CTER, a CTF parameters estimation method distinguished by its computational efficiency. The efficiency of the method makes it suitable for high-LhroughpuL EM data collection, and enables the use of a statistical resampling technique, bootstrap, that yields standard deviations of estimated defocus arid astigmatism amplitude arid angle, thus facilitating the automation of the process of screening out inferior micrograph data. Furthermore. CTER also outputs the spatial frequency limit imposed by reciprocal space aliasing of the discrete form of the CTF and the finite window size. We demonstrate the efficiency and accuracy of CTER using a data set collected on a 300 kV Tecnai Polara (FEU using the K2 Summit DED camera in super resoluLion counting mode. Using CTER we obtained a structure of the 80S ribosome whose large subunit had a resolution of 4.03 angstrom without, and 3.85 angstrom with, inclusion of astigmatism parameters.(C) 2014 Elsevier B.V. All rights reserved
引用
收藏
页码:9 / 19
页数:11
相关论文
共 49 条
[1]  
[Anonymous], 1994, NUMERICAL RECIPES C
[2]   Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles [J].
Bai, Xiao-chen ;
Fernandez, Israel S. ;
McMullan, Greg ;
Scheres, Sjors H. W. .
ELIFE, 2013, 2
[3]   Direct electron detection yields cryo-EM reconstructions at resolutions beyond 3/4 Nyquist frequency [J].
Bammes, Benjamin E. ;
Rochat, Ryan H. ;
Jakana, Joanita ;
Chen, Dong-Hua ;
Chiu, Wah .
JOURNAL OF STRUCTURAL BIOLOGY, 2012, 177 (03) :589-601
[4]   Practical performance evaluation of a 10k x 10k CCD for electron cryo-microscopy [J].
Bammes, Benjamin E. ;
Rochat, Ryan H. ;
Jakana, Joanita ;
Chiu, Wah .
JOURNAL OF STRUCTURAL BIOLOGY, 2011, 175 (03) :384-393
[5]   EFFICIENT ALGORITHM FOR DISCRETE L1 LINEAR-APPROXIMATION WITH LINEAR CONSTRAINTS [J].
BARRODALE, I ;
ROBERTS, FDK .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 1978, 15 (03) :603-611
[6]   Beam-induced motion of vitrified specimen on holey carbon film [J].
Brilot, Axel F. ;
Chen, James Z. ;
Cheng, Anchi ;
Pan, Junhua ;
Harrison, Stephen C. ;
Potter, Clinton S. ;
Carragher, Bridget ;
Henderson, Richard ;
Grigorieff, Nikolaus .
JOURNAL OF STRUCTURAL BIOLOGY, 2012, 177 (03) :630-637
[7]   Movies of Ice-Embedded Particles Enhance Resolution in Electron Cryo-Microscopy [J].
Campbell, Melody G. ;
Cheng, Anchi ;
Brilot, Axel F. ;
Moeller, Arne ;
Lyumkis, Dmitry ;
Veesler, David ;
Pan, Junhua ;
Harrison, Stephen C. ;
Potter, Clinton S. ;
Carragher, Bridget ;
Grigorieff, Nikolaus .
STRUCTURE, 2012, 20 (11) :1823-1828
[8]   Leginon: An automated system for acquisition of images from vitreous ice specimens [J].
Carragher, B ;
Kisseberth, N ;
Kriegman, D ;
Milligan, RA ;
Potter, CS ;
Pulokas, J ;
Reilein, A .
JOURNAL OF STRUCTURAL BIOLOGY, 2000, 132 (01) :33-45
[9]   Achievable resolution from images of biological specimens acquired from a 4k x 4k CCD camera in a 300-kV electron cryomicroscope [J].
Chen, Dong-Hua ;
Jakana, Joanita ;
Liu, Xiangan ;
Schmid, Michael F. ;
Chiu, Wah .
JOURNAL OF STRUCTURAL BIOLOGY, 2008, 163 (01) :45-52
[10]  
Frank J., 2006, Three-dimensional electron microscopy of macromolecular assemblies: visualization of biological molecules in their native state