摘要
Purpose: The surface integrity associated with implant placement was examined to determine whether the topography of common implant surface modifications is retained after implant insertion. Materials and Methods: Turned (TV), acid-etched (AE), and anodized (AN) experimental implants prepared in-house were inserted into polyurethane foam blocks using a standard drilling protocol at maximum torque of 37 Ncm. Qualitative analysis of the surfaces of preinserted and postinserted implants was done by scanning electron microscopy (SEM), and quantitative analysis of the implant threads was performed by interferometry. Among the roughness parameters calculated were average height deviation (Sa), peak height above core roughness (Spk), and maximum peak height (Sp). Results: SEM showed that TV implants exhibited similar morphology before and after implant insertion. The AE implants showed reduced peak height associated with flattened areas after insertion. AN implants demonstrated the most extensive damage associated with insertion; the entire porous oxide layer had been removed at the apical region and on the crests of the threads. Surface roughness evaluation was corroborated with the SEM findings. Roughness parameters were similar for TV implants, and reduced Sp and Spk values were observed for the AE implants after insertion. AN implants were more complex to measure quantitatively because of variations in the extent of damage to the oxide layer during insertion. In some cases, the AN layer had been completely removed, exposing the underlying material and clearly decreasing the roughness, and in other cases it remained intact and rough. Polyurethane foam blocks in contact with AN implants demonstrated loose titanium particles of different sizes. Conclusion: This preliminary study demonstrated surface damage after insertion of experimental anodized implants into polyurethane blocks associated with loose titanium particles at the interface. Future in vivo studies should investigate the relevance of such loose particles on the peri-implant bone response.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [21] Organic-inorganic surface modifications for titanium implant surfaces
    de Jonge, Lise T.
    Leeuwenburgh, Sander C. G.
    Wolke, Joop G. C.
    Jansen, John A.
    PHARMACEUTICAL RESEARCH, 2008, 25 (10) : 2357 - 2369
  • [22] The Impact of Dental Implant Surface Modifications on Osseointegration and Biofilm Formation
    Kligman, Stefanie
    Ren, Zhi
    Chung, Chun-Hsi
    Perillo, Michael Angelo
    Chang, Yu-Cheng
    Koo, Hyun
    Zheng, Zhong
    Li, Chenshuang
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (08)
  • [23] The Effect of Implant Surface Modifications on Survival and Bone Loss of Immediately Loaded Implants in the Edentulous Mandible
    Vervaeke, Stijn
    Collaert, Bruno
    De Bruyn, Hugo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (05) : 1352 - 1357
  • [24] Enhancing surface integrity and performance of EDM with sustainable dielectrics and electrode modifications
    Rakshaskar, Rajnitu
    Kannan, C.
    ENGINEERING RESEARCH EXPRESS, 2024, 6 (02):
  • [25] Correlation between Implant Surface Roughness and Implant Stability: A Systematic Review
    Romero-Serrano, Marta
    Romero-Ruiz, Manuel-Maria
    Herrero-Climent, Mariano
    Rios-Carrasco, Blanca
    Gil-Mur, Javier
    DENTISTRY JOURNAL, 2024, 12 (09)
  • [26] Interaction of progenitor bone cells with different surface modifications of titanium implant
    Chen, Wen-Cheng
    Chen, Ya-Shun
    Ko, Chia-Ling
    Lin, Yi
    Kuo, Tzu-Huang
    Kuo, Hsien-Nan
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 37 : 305 - 313
  • [27] Maintenance of implants: An in vitro study of titanium implant surface modifications subsequent to the application of different prophylaxis procedures
    Matarasso, S
    Quaremba, G
    Coraggio, F
    Vaia, E
    Cafiero, C
    Lang, NP
    CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (01) : 64 - 72
  • [28] Implant-bone-interface: Reviewing the impact of titanium surface modifications on osteogenic processes in vitro and in vivo
    Stich, Theresia
    Alagboso, Francisca
    Krenek, Tomas
    Kovarik, Tomas
    Alt, Volker
    Docheva, Denitsa
    BIOENGINEERING & TRANSLATIONAL MEDICINE, 2022, 7 (01)
  • [29] Osteophilic properties of bone implant surface modifications in a cassette model on a decorticated goat spinal transverse process
    van Oirschot, Bart A. J. A.
    Eman, Rhandy M.
    Habibovic, Pamela
    Leeuwenburgh, Sander C. G.
    Tahmasebi, Zeinab
    Weinans, Harrie
    Alblas, Jacqueline
    Meijer, Gert J.
    Jansen, John A.
    van den Beucken, Jeroen J. J. P.
    ACTA BIOMATERIALIA, 2016, 37 : 195 - 205
  • [30] Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torque
    Duyck, Joke
    Corpas, Livia
    Vermeiren, Stephanie
    Ogawa, Toru
    Quirynen, Marc
    Vandamme, Katleen
    Jacobs, Reinhilde
    Naert, Ignace
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (08) : 877 - 884