Integrity of Implant Surface Modifications After Insertion

被引:33
|
作者
Mints, Daniel [1 ]
Elias, Carlos [2 ]
Funkenbusch, Paul [3 ]
Meirelles, Luiz [4 ]
机构
[1] Univ Rochester, Eastman Dent Ctr, Dept Biomed Engn, Div Prosthodont, Rochester, NY 14620 USA
[2] Inst Mil Engn, Dept Biomat, Biomat Lab, Rio De Janeiro, RJ, Brazil
[3] Univ Rochester, Hajim Sch Engn & Appl Sci, Dept Mech Engn, Rochester, NY USA
[4] Univ Rochester, Eastman Inst Oral Hlth, Rochester, NY USA
关键词
dental implants; osteolysis; surface characterization; surface roughness; TITANIUM IMPLANTS; BONE; PARTICLES; ROUGHNESS; REMOVAL; TORQUE;
D O I
10.11607/jomi.3259
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The surface integrity associated with implant placement was examined to determine whether the topography of common implant surface modifications is retained after implant insertion. Materials and Methods: Turned (TV), acid-etched (AE), and anodized (AN) experimental implants prepared in-house were inserted into polyurethane foam blocks using a standard drilling protocol at maximum torque of 37 Ncm. Qualitative analysis of the surfaces of preinserted and postinserted implants was done by scanning electron microscopy (SEM), and quantitative analysis of the implant threads was performed by interferometry. Among the roughness parameters calculated were average height deviation (Sa), peak height above core roughness (Spk), and maximum peak height (Sp). Results: SEM showed that TV implants exhibited similar morphology before and after implant insertion. The AE implants showed reduced peak height associated with flattened areas after insertion. AN implants demonstrated the most extensive damage associated with insertion; the entire porous oxide layer had been removed at the apical region and on the crests of the threads. Surface roughness evaluation was corroborated with the SEM findings. Roughness parameters were similar for TV implants, and reduced Sp and Spk values were observed for the AE implants after insertion. AN implants were more complex to measure quantitatively because of variations in the extent of damage to the oxide layer during insertion. In some cases, the AN layer had been completely removed, exposing the underlying material and clearly decreasing the roughness, and in other cases it remained intact and rough. Polyurethane foam blocks in contact with AN implants demonstrated loose titanium particles of different sizes. Conclusion: This preliminary study demonstrated surface damage after insertion of experimental anodized implants into polyurethane blocks associated with loose titanium particles at the interface. Future in vivo studies should investigate the relevance of such loose particles on the peri-implant bone response.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [1] Impact of High Insertion Torque on Implant Surface Integrity
    Dodo, Cindy
    Senna, Plinio Mendes
    Cury, Altair Antoninha Del Bel
    Meirelles, Luiz
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2025, 27 (02)
  • [2] Does implant surface hydrophilicity influence the maintenance of surface integrity after insertion into low-density artificial bone?
    Ferreira Silva, Gabrielle Alencar
    Faot, Fernanda
    da Silva, Wander Jose
    Del Bel Cury, Altair Antoninha
    DENTAL MATERIALS, 2021, 37 (02) : E69 - E84
  • [3] Zirconia surface modifications for implant dentistry
    Schunemann, Fernanda H.
    Galarraga-Vinueza, Maria E.
    Magini, Ricardo
    Fredel, Marcio
    Silva, Filipe
    Souza, Julio C. M.
    Zhang, Yu
    Henriques, Bruno
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 1294 - 1305
  • [4] Dental implant surfaces after insertion in bone: an in vitro study in four commercial implant systems
    Deppe, Herbert
    Wolff, Carolina
    Bauer, Florian
    Ruthenberg, Ricarda
    Sculean, Anton
    Muecke, Thomas
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (03) : 1593 - 1600
  • [5] Zirconia Dental Implant Designs and Surface Modifications: A Narrative Review
    Ciszynski, Michal
    Chwaliszewski, Bartosz
    Simka, Wojciech
    Dominiak, Marzena
    Gedrange, Tomasz
    Hadzik, Jakub
    MATERIALS, 2024, 17 (17)
  • [6] EFFECTS OF SURFACE MODIFICATIONS WITH OXALIC ACID ETCHING AND SANDBLASTING ON SURFACE TOPOGRAPHY AND BIOCOMPATIBILITY OF cpTi SURFACES
    Yeniyol, Sinem
    Bolukbasi, Nilufer
    Cakir, Ali Fuat
    Bilir, Ayhan
    Ozdemir, Tayfun
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2013, 27 (04) : 3995 - 4001
  • [7] Influence of Surface Modifications on Bacterial Adherence to Implant Abutment Materials
    Ozer, Fusun
    Anadioti, Eva
    Mack, Yvonne
    Sen, Deniz
    DiRienzo, Joseph
    Blatz, Markus
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2022, 42 (05) : 657 - 663
  • [8] Influence of Dental Implant Surface Modifications on Osseointegration and Biofilm Attachment
    Han, Wen
    Fang, Shuobo
    Zhong, Qun
    Qi, Shengcai
    COATINGS, 2022, 12 (11)
  • [9] Advances in implant surface modifications to improve osseointegration
    Zhu, Guang
    Wang, Guocheng
    Li, Jiao Jiao
    MATERIALS ADVANCES, 2021, 2 (21): : 6901 - 6927
  • [10] Impact of Dental Implant Surface Modifications on Osseointegration
    Smeets, Ralf
    Stadlinger, Bernd
    Schwarz, Frank
    Beck-Broichsitter, Benedicta
    Jung, Ole
    Precht, Clarissa
    Kloss, Frank
    Groebe, Alexander
    Heiland, Max
    Ebker, Tobias
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016