Evaluation of a Fuzzy-Based Impedance Control Strategy on a Powered Lower Exoskeleton

被引:44
作者
Huu Toan Tran [1 ,2 ]
Cheng, Hong [1 ]
Rui, Huang [1 ]
Lin, XiChuan [1 ]
Mien Ka Duong [1 ]
Chen, QiMing [1 ]
机构
[1] Univ Elect Sci & Technol China, Ctr Robot, Chengdu 611731, Sichuan, Peoples R China
[2] Ind Univ Ho Chi Minh City, Fac Elect Technol, Ho Chi Minh City 700000, Vietnam
基金
中国国家自然科学基金;
关键词
Lower exoskeleton; Wearable robotics; Assist robotics; Impedance control; Fuzzy logic control; Physical human-robot interaction; LEG EXOSKELETON; FORCE TRACKING; WALKING SPEED; ROBOT; DESIGN; ORTHOSIS; ASSIST;
D O I
10.1007/s12369-015-0324-9
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This paper comprehensively presents the analysis, design, and control of a wearable lower limb exoskeleton intended to enhance human performance and support load-carrying. The exoskeleton is powered at hip and knee joints to provide maximum joint torques of 74 Nm for the joint flexion/extension augmentation and load support. Typical issues regarding the implementation of the exoskeleton, such as mechanical design, sensory system, distributed embedded system, and high-speed networked control architecture are briefly presented. In order to control the coupled human-robot system, a new fuzzy-based impedance control strategy, previously developed by the authors, is used to provide assistive torques by regulating the desired impedance between the exoskeleton and a wearer's limb according to a specific motion speed. The effect of human behaviours on the change of impedance parameters across variable walking speeds is adopted to design the fuzzy rules for the control strategy. As a result, the fuzzy-based impedance regulation is separately designed for swing and stance walking phases to adapt to the change. The control performance of the designed exoskeleton evaluated on a bench-testing over different ranges of walking speeds (about 0.3-1.2 m/s) have demonstrated that, resulting interaction torque, human-exoskeleton tracking error, and electrical power consumption are significantly reduced as compared to a traditional impedance control. Besides that, an average of 72.3 % of the load is transferred to the ground by the exoskeleton during the stance phase of walking. The developed control strategy on the lower exoskeleton has the potential to increase comfort and adaptation to users during daily use.
引用
收藏
页码:103 / 123
页数:21
相关论文
共 66 条
  • [1] Active-impedance control of a lower-limb Assistive exoskeleton
    Aguirre-Ollinger, Gabriel
    Colgate, J. Edward
    Peshkin, Michael A.
    Goswami, Ambarish
    [J]. 2007 IEEE 10TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, VOLS 1 AND 2, 2007, : 188 - +
  • [2] The design and control of a therapeutic exercise robot for lower limb rehabilitation: Physiotherabot
    Akdogan, Erhan
    Adli, Mehmet Arif
    [J]. MECHATRONICS, 2011, 21 (03) : 509 - 522
  • [3] HYBRID IMPEDANCE CONTROL OF ROBOTIC MANIPULATORS
    ANDERSON, RJ
    SPONG, MW
    [J]. IEEE JOURNAL OF ROBOTICS AND AUTOMATION, 1988, 4 (05): : 549 - 556
  • [4] [Anonymous], 1998, Fuzzy control
  • [5] [Anonymous], 1992, GAIT ANAL NORMAL PAT
  • [6] [Anonymous], 2011, INT SYST APPL ISA 20, DOI [DOI 10.1145/2063384.2063479, DOI 10.1145/2072298.2071964]
  • [7] Astrom K.J., 1995, ADAPTIVE CONTROL
  • [8] Au SK, 2008, IEEE ROBOT AUTOM MAG, V15, P52, DOI 10.1109/MRA.2008.927697
  • [9] Gait analysis using a shoe-integrated wireless sensor system
    Bamberg, Stacy J. Morris
    Benbasat, Ari Y.
    Scarborough, Donna Moxley
    Krebs, David E.
    Paradiso, Joseph A.
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (04): : 413 - 423
  • [10] Bamieh B, 2001, P EUR CONTR C