Feasibility of automated detection of advanced sleep disordered breathing utilizing an implantable pacemaker ventilation sensor

被引:37
作者
Shalaby, Alaa
Atwood, Charles
Hansen, Claudius
Konermann, Martin
Jamnadas, Pradip
Lee, Kent
Willems, Roger
Hartley, Jesse
Stahmann, Jeffrey
Kwok, Jonathan
Ni, Quan
Neuzner, Joerg
机构
[1] Univ Pittsburgh, Pittsburgh VA Healthcare Syst, Div Cardiol, Pittsburgh, PA 15240 USA
[2] Pittsburgh VA Healthcare Syst, Div Pulmonol, Pittsburgh, PA USA
[3] Univ Pittsburgh, Div Pulmonol, Pittsburgh, PA USA
[4] Klinikum Kassel, Dept Cardiol, Kassel, Germany
[5] Marienkrankenhaus Kassel, Dept Pulmonol, Kassel, Germany
[6] Cardiovasc Intervent, Orlando, FL USA
[7] Guidant Cardiac Rhythm Management, Appl Res, St Paul, MN USA
[8] Guidant Europe, Clin Res, Diegem, Belgium
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2006年 / 29卷 / 10期
关键词
pacemakers; respiration; sleep opnea; diagnosis;
D O I
10.1111/j.1540-8159.2006.00496.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study tested the feasibility of automatically detecting advanced sleep disordered breathing (SDB) from a pacemaker trans-thoracic impedance sensor. Background: SDB is prevalent yet under-diagnosed in patients with cardiovascular disease. The potential for automated detection of SDB in patients receiving pacemakers with respiration sensors has not been fully explored. We hypothesized that the trans-thoracic impedance sensor could be utilized for automatic detection of advanced SDB. Methods: Patients underwent overnight polysomnography (PSG). The pacemaker trans-thoracic impedance signal was simultaneously recorded and time synchronized with the polysomnograph. Cardiovascular health variables were abstracted from medical records. Apnea was defined as cessation of inspiratory airflow lasting 10 seconds or longer. Hypopnea was defined as a reduction of tidal volume of at least 30% from baseline tidal volume, lasting 10 seconds or more. A computer algorithm (PM-A) was developed to automatically detect SDB from the pacemaker impedance sensor data. The performance of automated SDB detection was compared against PSG. Results: Sixty patients (aged 69 +/- 12 years, 45 males) were studied. Advanced SDB (moderate or severe) was diagnosed in 40 patients. Severe SDB (apnea-hypopnea index [AHI] >= 30) was diagnosed in 32 patients (53%), but only 5 patients had prior diagnosis of the disease. Moderate SDB (30 > AHI > 15) was diagnosed in 8 patients of whom only two were previously diagnosed. Cardiovascular health variables did not predict the presence of advanced SDB. PM-A derived AHI correlated with that of the PSG (r = 0.80, P < 0.01). The algorithm identified patients with advanced SDB with 82% sensitivity and 88% specificity. Conclusions: It is feasible to automatically measure SDB severity using a pacemaker trans-thoracic impedance sensor. Advanced SDB was frequently undiagnosed in this cohort of pacemaker patients.
引用
收藏
页码:1036 / 1043
页数:8
相关论文
共 47 条
[1]  
*AM HEART ASS, 2003, HEART DIS STROK STAT
[2]   Effect of nasal continuous positive airway pressure treatment on blood pressure in patients with obstructive sleep apnea [J].
Becker, HF ;
Jerrentrup, A ;
Ploch, T ;
Grote, L ;
Penzel, T ;
Sullivan, CE ;
Peter, JH .
CIRCULATION, 2003, 107 (01) :68-73
[3]   Sleep apnea and heart failure - Part I: Obstructive sleep apnea [J].
Bradley, TD ;
Floras, JS .
CIRCULATION, 2003, 107 (12) :1671-1678
[4]   Sleep apnea and heart failure - Part II: Central sleep apnea [J].
Bradley, TD ;
Floras, JS .
CIRCULATION, 2003, 107 (13) :1822-1826
[5]   BREATHING PATTERN ABNORMALITIES AND ARTERIAL OXYGEN DESATURATION DURING SLEEP IN THE CONGESTIVE-HEART-FAILURE SYNDROME - IMPROVEMENT FOLLOWING MEDICAL THERAPY [J].
DARK, DS ;
PINGLETON, SK ;
KERBY, GR ;
CRABB, JE ;
GOLLUB, SB ;
GLATTER, TR ;
DUNN, MI .
CHEST, 1987, 91 (06) :833-836
[6]   Automatic recognition of abnormal respiratory events during sleep by a pacemaker transthoracic impedance sensor [J].
Defaye, P ;
Pépin, JL ;
Poezevara, Y ;
Mabo, P ;
Murgatroyd, F ;
Lévy, P ;
Garrigue, S .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (09) :1034-1040
[7]  
*DHHS, 2002, MED COV ISS MAN, P16
[8]   Clinical evaluation of a pacemaker algorithm that adjusts the pacing rate during sleep using activity variance [J].
Duru, F ;
Bloch, KE ;
Weilenmann, D ;
Candinas, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (10) :1509-1515
[9]   A sleeping giant - Sleep-disordered breathing in the coronary care unit [J].
Feinsilver, SH .
CHEST, 2005, 127 (01) :4-5
[10]   Sleep-related breathing disorders are associated with ventricular arrhythmias in patients with an implantable cardioverter-defibrillator [J].
Fichter, J ;
Bauer, D ;
Arampatzis, S ;
Fries, R ;
Heisel, A ;
Sybrecht, GW .
CHEST, 2002, 122 (02) :558-561