Resolving Reflection and Resolution in 3D Imaging of Fresh Bone

被引:3
|
作者
Imran, Rabbia [1 ]
Rogers, Tracy L. [1 ]
机构
[1] Univ Toronto Mississauga, 3359 Mississauga Rd, Mississauga, ON L5L 1C6, Canada
关键词
forensic science; forensic anthropology; structured light scanning; 3D images; reflection; resolution; fresh bone; saw marks;
D O I
10.1111/1556-4029.14136
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Structured light scanning is a noninvasive, accurate, and cost-effective 3D imaging technique, but due to reflection issues is yet to be utilized for tool mark analysis on fresh bone. During imaging, reflection from shiny surfaces, such as greasy bone, disrupts image formation. This study tested the David SLS-1 scanner's ability to image saw marks and explored six strategies to reduce reflection by [1] dulling the surface or [2] altering the projected light. The surface was dulled by freezing, talcum powder, dulling spray, or compressed air. The projected light was altered with a diffuser or limited to single pattern-coded. Results demonstrated that the resolution was insufficient for capturing minute details of striae. All six tests failed to reduce reflection sufficiently to produce complete images, but projecting vertical pattern-coded light showed the most promise. Future research is required concentrating on enhancing resolution and exploring the role of pattern-coded light in reducing reflection.
引用
收藏
页码:200 / 208
页数:9
相关论文
empty
未找到相关数据