Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist

被引:21
|
作者
Sutherland, John K. [1 ]
Nozaki, Taiki [1 ]
Kaneko, Yasuhito [1 ]
Yu, Hon J. [2 ,3 ]
Rafijah, Gregory [4 ]
Hitt, David [5 ]
Yoshioka, Hiroshi [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, UCI Med Ctr, Orange, CA 92686 USA
[2] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92686 USA
[3] John Tu & Thomas Yuen Ctr Funct Oncoimaging Irvin, Irvine, CA USA
[4] Univ Calif Irvine, Dept Orthopaed Surg, Irvine, CA 92686 USA
[5] Philips Med Syst, Cleveland, OH USA
来源
BMC MUSCULOSKELETAL DISORDERS | 2016年 / 17卷
关键词
Musculoskeletal MRI; 3D MR imaging; MR arthrography; Wrist MRI; SPIN-ECHO; TRIANGULAR FIBROCARTILAGE; LIGAMENTS; PAIN; ARTHROSCOPY; KNEE;
D O I
10.1186/s12891-016-0890-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Our study was performed to evaluate the image quality of 3 T MR wrist arthrograms with attention to ulnar wrist structures, comparing image quality of isotropic 3D proton density fat suppressed turbo spin echo (PDFS TSE) sequence versus standard 2D 3 T sequences as well as comparison with 1.5 T MR arthrograms. Methods: Eleven consecutive 3 T MR wrist arthrograms were performed and the following sequences evaluated: 3D isotropic PDFS, repetition time/echo time (TR/TE) 1400/28.3 ms, voxel size 0.35x0.35x0.35 mm, acquisition time 5 min; 2D coronal sequences with slice thickness 2 mm: T1 fat suppressed turbo spin echo (T1FS TSE) (TR/TE 600/20 ms); proton density (PD) TSE (TR/TE 3499/27 ms). A 1.5 T group of 18 studies with standard sequences were evaluated for comparison. All MR imaging followed fluoroscopically guided intra-articular injection of dilute gadolinium contrast. Qualitative assessment related to delineation of anatomic structures between 1.5 T and 3 T MR arthrograms was carried out using Mann-Whitney test and the differences in delineation of anatomic structures among each sequence in 3 T group were analyzed with Wilcoxon signed-rank test. Quantitative assessment of mean relative signal intensity (SI) and relative contrast measurements was performed using Wilcoxon signed-rank test. Results: Mean qualitative scores for 3 T sequences were significantly higher than 1.5 T (p < 0.01), with isotropic 3D PDFS sequence having highest mean qualitative scores (p < 0.05). Quantitative analysis demonstrated no significant difference in relative signal intensity among the 3 T sequences. Significant differences were found in relative contrast between fluid-bone and fluid-fat comparing 3D and 2D PDFS (p < 0.01). Conclusions: 3D isotropic PDFS sequence showed promise in both qualitative and quantitative assessment, suggesting this may be useful for MR wrist arthrograms at 3 T. Primary reasons for diagnostic potential include the ability to make reformations in any obliquity to follow the components of ulnar side wrist structures including triangular fibrocartilage complex. Additionally, isotropic imaging provides thinner slice thickness with less partial volume averaging allowing for identification of subtle injuries.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] BP4D-Spontaneous: a high-resolution spontaneous 3D dynamic facial expression database
    Zhang, Xing
    Yin, Lijun
    Cohn, Jeffrey F.
    Canavan, Shaun
    Reale, Michael
    Horowitz, Andy
    Liu, Peng
    Girard, Jeffrey M.
    IMAGE AND VISION COMPUTING, 2014, 32 (10) : 692 - 706
  • [42] Can isotropic fast gradient echo imaging substituted for conventional T1 weighted in shoulder MR arthrography at 3 Tesla?
    Magee, Thomas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (01) : 118 - 122
  • [43] 3-T direct MR arthrography of the wrist: Value of finger trap distraction to assess intrinsic ligament and triangular fibrocartilage complex tears
    Cerny, Milena
    Marlois, Romain
    Theumann, Nicolas
    Bollmann, Christof
    Wehrli, Laurent
    Richarme, Delphine
    Meuli, Reto
    Becce, Fabio
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) : E582 - E589
  • [44] Determination of skeletal tumor extent: is an isotropic T1-weighted 3D sequence adequate?
    Luna, Rodrigo
    Fritz, Jan
    del Grande, Filippo
    Ahlawat, Shivani
    Fayad, Laura M.
    EUROPEAN RADIOLOGY, 2021, 31 (05) : 3138 - 3146
  • [45] Conventional 3-T MRI and 1.5-T MR Arthrography of Femoroacetabular Impingement
    Robinson, Philip
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (03) : 509 - 515
  • [46] Multiaxial 3D MRI of the Ankle Advanced High-Resolution Visualization of Ligaments, Tendons, and Articular Cartilage
    Fritz, Benjamin
    de Cesar Netto, Cesar
    Fritz, Jan
    FOOT AND ANKLE CLINICS, 2023, 28 (03) : 529 - 550
  • [47] Multiaxial 3D MRI of the Ankle Advanced High-Resolution Visualization of Ligaments, Tendons, and Articular Cartilage
    Fritz, Benjamin
    Netto, Cesar de Cesar
    Fritz, Jan
    CLINICS IN PODIATRIC MEDICINE AND SURGERY, 2024, 41 (04) : 685 - 706
  • [48] MRI of the Knee Ligaments and Menisci: Comparison of Isotropic-Resolution 3D and Conventional 2D Fast Spin-Echo Sequences at 3 T
    Subhas, Naveen
    Kao, Amy
    Freire, Maxime
    Polster, Joshua M.
    Obuchowski, Nancy A.
    Winalski, Carl S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : 442 - 450
  • [49] Current Perspectives on the Advantages of 3-T MR Imaging of the Wrist
    Chhabra, Avneesh
    Soldatos, Theodoros
    Thawait, Gaurav K.
    Del Grande, Filippo
    Thakkar, Rashmi S.
    Means, Kenneth R., Jr.
    Carrino, John A.
    RADIOGRAPHICS, 2012, 32 (03) : 879 - 896
  • [50] Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): Initial experience
    Gold, Garry E.
    Busse, Reed F.
    Beehler, Carol
    Han, Eric
    Brau, Anja C. S.
    Beatty, Philip J.
    Beaulieu, Christopher F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : 1287 - 1293