Macroporous graphene capped Fe3O4 for amplified electrochemiluminescence immunosensing of carcinoembryonic antigen detection based on CeO2@TiO2

被引:103
|
作者
Yang, Lei [1 ]
Zhu, Wenjuan [1 ]
Ren, Xiang [1 ]
Khan, Malik Saddam [1 ]
Zhang, Yong [1 ]
Du, Bin [1 ]
Wei, Qin [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Key Lab Chem Sensing & Anal Univ Shandong, Jinan 250022, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2017年 / 91卷
基金
中国国家自然科学基金;
关键词
Electrochemiluminescence; Immunosensor; Carcinoembryonic antigen; Graphene capped Fe3O4; CeO2@TiO2; CARBON ELECTRODE; REDUCED GRAPHENE; OXIDE; AMPLIFICATION; BIOSENSOR; FILM; NANOPARTICLES; IMMUNOASSAY; COMPOSITE; PLATFORM;
D O I
10.1016/j.bios.2017.01.055
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel electrochemiluminescence (ECL) signal-amplified immunosensing strategy was proposed by using gold nanoparticles (Au NPs) functionalized reduced graphene oxide (rGO) capped Fe3O4 (Au-FrGO). In this work, CeO2@TiO2 was prepared by a sol-gel method to wrap CeO2 with TiO2. In the presence of CeO2, CeO2@TiO2 exhibited better ECL activity than TiO2 with peroxydisulfate as coreactant. In addition, FrGO with macroporous structure was synthesized by self-assembly of rGO sheets capped cationic Fe3O4 nanoparticles, exhibiting larger specific surface area than rGO. Due to the low toxicity and magnetism of Fe3O4, FrGO owned more favorable biocompatibility and the application of magnetic-separation simplified the preparation procedure. After hybridizing with Au NPs, FrGO exhibited more excellent electrical conductivity and could immobilize more CeO2@TiO2 and antibodies. Therefore, a novel label-free ECL immunosensor based on Au-FrGO-CeO2@TiO2 was constructed which generated higher ECL response. To investigate the performance of the immunosensor, carcinoembryonic antigen (CEA) was chosen as a model target analyte. Under optimal conditions, the immunosensor had sensitive response to CEA in a wide linear range of 0.01 pg mL(-1) to 10 ng mL(-1) with a detection limit of 3.28 fg mL(-1). The proposed ECL immunosensor exhibited excellent stability, repeatability and selectivity, which opened another promising avenue for CEA determination in real serum samples.
引用
收藏
页码:842 / 848
页数:7
相关论文
共 50 条
  • [1] Electrochemical immunosensor for carcinoembryonic antigen based on signal amplification strategy of graphene and Fe3O4/Au NPs
    Peng, Dong
    Liang, Ru-Ping
    Huang, He
    Qiu, Jian-Ding
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 761 : 112 - 117
  • [2] An ultrasensitive immunosensor based on manganese dioxide-graphene nanoplatelets and core shell Fe3O4@Au nanoparticles for label-free detection of carcinoembryonic antigen
    Butmee, Preeyanut
    Tumcharern, Gamolwan
    Thouand, Gerald
    Kalcher, Kurt
    Samphao, Anchalee
    BIOELECTROCHEMISTRY, 2020, 132
  • [3] 3D Nanostructured Palladium-Functionalized Graphene-Aerogel-Supported Fe3O4 for Enhanced Ru(bpy)32+-Based Electrochemiluminescent Immunosensing of Prostate Specific Antigen
    Yang, Lei
    Li, Yueyuan
    Zhang, Yong
    Fan, Dawei
    Pang, Xuehui
    Wei, Qin
    Du, Bin
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (40) : 35260 - 35267
  • [4] Corallite-like Magnetic Fe3O4@MnO2@Pt Nanocomposites as Multiple Signal Amplifiers for the Detection of Carcinoembryonic Antigen
    Wu, Dan
    Ma, Hongmin
    Zhang, Yong
    Jia, Hongying
    Yan, Tao
    Wei, Qin
    ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (33) : 18786 - 18793
  • [5] Magnetic Fe3O4@TiO2 nanoparticles-based test strip immunosensing device for rapid detection of phosphorylated butyrylcholinesterase
    Ge, Xiaoxiao
    Zhang, Weiying
    Lin, Yuehe
    Du, Dan
    BIOSENSORS & BIOELECTRONICS, 2013, 50 : 486 - 491
  • [6] A Magnet-Controlled and Renewable Amperometric Immunosensor for Carcinoembryonic Antigen Based on Magnetic Fe3O4(core)/Au(shell) Nanoparticles Modified Screen-Printed Carbon Electrode
    Gan, Ning
    Meng, Linghua
    Li, Tianhua
    Cao, Yuting
    Zheng, Lei
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (07) : 3261 - 3267
  • [7] Capped and coupled Fe3O4/TiO2 nanopowder systems fabricated by sol-gel and a nonthermal method
    Niyaifar, Mohammad
    Hasanpour, Ahmad
    Mohammadpour, Hory
    Amighian, Jamshid
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2013, 210 (06): : 1190 - 1194
  • [8] Electrochemiluminescence Immunosensor for the Detection of Carcinoembryonic Antigen Based on Oxygen Vacancy-Rich Co3O4 Nanorods and Luminol
    Tang, Yun
    Zhang, Bihong
    Wang, Yuan
    Zhao, Faqiong
    Zeng, Baizhao
    ACS APPLIED NANO MATERIALS, 2021, 4 (07) : 7264 - 7271
  • [9] Electrochemical Sensing of H2O2 by Employing a Flexible Fe3O4/Graphene/Carbon Cloth as Working Electrode
    Sobahi, Nebras
    Imran, Mohd
    Khan, Mohammad Ehtisham
    Mohammad, Akbar
    Alam, Md. Mottahir
    Yoon, Taeho
    Mehedi, Ibrahim M.
    Hussain, Mohammad A.
    Abdulaal, Mohammed J.
    Jiman, Ahmad A.
    MATERIALS, 2023, 16 (07)
  • [10] Potential use of CeO2, TiO2 and Fe3O4 nanoparticles for the removal of cadmium from water
    Rebecca Contreras, Ada
    Garcia, Ana
    Gonzalez, Edgar
    Casals, Eudald
    Puntes, Victor
    Sanchez, Antoni
    Font, Xavier
    Recillas, Sonia