Chronopotentiometry of pure electrolytes with anion-exchange donnan exclusion membranes

被引:8
|
作者
Crespo, Gaston A. [1 ]
Afshar, Majid Ghahraman [1 ]
Bakker, Eric [1 ]
机构
[1] Univ Geneva, Dept Inorgan & Analyt Chem, CH-1211 Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
Chronopotentiometry; Perm-selective membranes; Ion-selective membranes; Electrical migration; ION-SELECTIVE ELECTRODES; SOLVENT POLYMERIC MEMBRANES; STEADY-STATE VOLTAMMETRY; SUPPORTING ELECTROLYTE; DIFFUSION-COEFFICIENTS; NAFION; TRANSPORT; HEPARIN; SENSORS; SURFACE;
D O I
10.1016/j.jelechem.2014.08.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We explore here the chronopotentiometric responses of pure electrolytes with anion-exchange Donnan exclusion membranes (IEDEM). As these electrolytes are locally depleted at the membrane surface in the absence of background electrolyte, electrical migration cannot be neglected. Yet, a linear relationship between the signal readout (square root of the transition time, tau(0.5)) and the electrolyte concentration is observed, albeit with much larger apparent diffusion coefficients than expected. We develop here a simplified migration-diffusion model based on the Nernst-Planck equation to explain the experimental data. As the flux of the counterion at the membrane surface must be zero for a permselective membrane, electrical migration is understood to precisely counteract the contribution of diffusional mass transport. This results in &simplified understanding of the mass transport processes at such membranes. Numerical simulations are performed to compare the predicted and experimental data. Based on these mechanistic and practical insights, permselective anion-exchange membranes are shown to respond to a range of ions in a similar fashion in the concentration range of 0.1-10 mM. The membranes are able to sustain significantly high current densities of 0.4 mA mm(-2) and may become useful as ion detectors or counter electrode separation materials. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:100 / 106
页数:7
相关论文
共 50 条
  • [1] Anion-exchange membranes for separation of borates by Donnan dialysis
    Bryjak, Marek
    Duraj, Ilona
    DESALINATION, 2013, 310 : 39 - 42
  • [2] Donnan dialysis with anion-exchange membranes in a water desalination system
    Rozanska, Agnieszka
    Wisniewski, Jacek
    Winnicki, Tomasz
    DESALINATION, 2006, 198 (1-3) : 236 - 246
  • [3] Transport of arsenate through anion-exchange membranes in Donnan dialysis
    Velizarov, Svetlozar
    JOURNAL OF MEMBRANE SCIENCE, 2013, 425 : 243 - 250
  • [4] Donnan dialysis with anion-exchange membranes as a pretreatment step before electrodialytic desalination
    Wisniewski, Jacek
    Rozanska, Agnieszka
    DESALINATION, 2006, 191 (1-3) : 210 - 218
  • [5] Fluoride removal from diluted solutions by Donnan dialysis with anion-exchange membranes
    Hichour, M
    Persin, F
    Molénat, J
    Sandeaux, J
    Gavach, C
    DESALINATION, 1999, 122 (01) : 53 - 62
  • [6] A comparative study on Donnan dialysis separation using homogeneous and heterogeneous anion-exchange membranes
    Breytus, Anna
    Huang, Yunyan
    Hasson, David
    Semiat, Raphael
    Shemer, Hilla
    DESALINATION AND WATER TREATMENT, 2021, 225 : 1 - 10
  • [7] Removal of bromide ions from an aqueous solution by Donnan dialysis with anion-exchange membranes
    Lakomska, Sylwia
    Wisniewski, Jacek
    DESALINATION AND WATER TREATMENT, 2013, 51 (7-9) : 1705 - 1711
  • [8] Fluoride removal by Donnan dialysis with plasma-modified and unmodified anion-exchange membranes
    Kir, Esengul
    Alkan, Esin
    DESALINATION, 2006, 197 (1-3) : 217 - 224
  • [9] MICROHETEROGENEITY OF ANION-EXCHANGE MEMBRANES
    MIZUTANI, Y
    KUSUMOTO, K
    NISHIMURA, M
    NISHIMURA, T
    JOURNAL OF APPLIED POLYMER SCIENCE, 1975, 19 (09) : 2537 - 2543
  • [10] ACIDIC WASTE-WATER TREATMENT BY DONNAN DIALYSIS INVOLVING TUBULAR ANION-EXCHANGE MEMBRANES
    WISNIEWSKA, G
    WINNICKI, T
    DESALINATION, 1988, 68 (2-3) : 121 - 130