Accurate model annotation of a near-atomic resolution cryo-EM map

被引:88
|
作者
Hryc, Corey F. [1 ]
Chen, Dong-Hua [2 ,6 ]
Afonine, Pavel V. [3 ]
Jakana, Joanita [2 ]
Wang, Zhao [2 ]
Haase-Pettingell, Cameron [4 ]
Jiang, Wen [5 ]
Adams, Paul D. [3 ]
King, Jonathan A. [4 ]
Schmid, Michael F. [1 ,2 ]
Chiu, Wah [1 ,2 ]
机构
[1] Baylor Coll Med, Grad Program Struct & Computat Biol & Mol Biophys, Houston, TX 77030 USA
[2] Baylor Coll Med, Verna & Marrs McLean Dept Biochem & Mol Biol, Natl Ctr Macromol Imaging, Houston, TX 77030 USA
[3] Lawrence Berkeley Natl Lab, Molr Biophys & Integrated Bioimaging Div, Berkeley, CA 94720 USA
[4] MIT, Dept Biol, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[5] Purdue Univ, Dept Biol Sci, W Lafayette, IN 47907 USA
[6] Stanford Univ, Dept Biol Struct, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
cryo-EM; P22; model; structure; annotation; PHAGE-P22 COAT PROTEIN; ELECTRON CRYSTALLOGRAPHY; VALIDATION; MICROSCOPY; RECONSTRUCTION;
D O I
10.1073/pnas.1621152114
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electron cryomicroscopy (cryo-EM) has been used to determine the atomic coordinates (models) from density maps of biological assemblies. These models can be assessed by their overall fit to the experimental data and stereochemical information. However, these models do not annotate the actual density values of the atoms nor their positional uncertainty. Here, we introduce a computational procedure to derive an atomic model from a cryo-EM map with annotated metadata. The accuracy of such a model is validated by a faithful replication of the experimental cryo-EM map computed using the coordinates and associated metadata. The functional interpretation of any structural features in the model and its utilization for future studies can be made in the context of its measure of uncertainty. We applied this protocol to the 3.3-angstrom map of the mature P22 bacteriophage capsid, a large and complex macromolecular assembly. With this protocol, we identify and annotate previously undescribed molecular interactions between capsid subunits that are crucial to maintain stability in the absence of cementing proteins or cross-linking, as occur in other bacteriophages.
引用
收藏
页码:3103 / 3108
页数:6
相关论文
共 50 条
  • [41] Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM
    Li, Xueming
    Mooney, Paul
    Zheng, Shawn
    Booth, Christopher R.
    Braunfeld, Michael B.
    Gubbens, Sander
    Agard, David A.
    Cheng, Yifan
    NATURE METHODS, 2013, 10 (06) : 584 - +
  • [42] D-loop Dynamics and Near-Atomic-Resolution Cryo-EM Structure of Phalloidin-Bound F-Actin
    Das, Sanchaita
    Ge, Peng
    Durer, Zeynep A. Oztug
    Grintsevich, Elena E.
    Zhou, Z. Hong
    Reisler, Emil
    STRUCTURE, 2020, 28 (05) : 586 - +
  • [43] High-Resolution Macromolecular Structure Determination by MicroED, a cryo-EM Method
    Rodriguez, J. A.
    Gonen, T.
    RESOLUTION REVOLUTION: RECENT ADVANCES IN CRYOEM, 2016, 579 : 369 - 392
  • [44] Segregation of lipids near acetylcholine-receptor channels imaged by cryo-EM
    Unwin, Nigel
    IUCRJ, 2017, 4 : 393 - 399
  • [45] Resolution advances in cryo-EM enable application to drug discovery
    Subramaniam, Sriram
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2017, 73 : C37 - C37
  • [46] Use of evolutionary information in the fitting of atomic level protein models in low resolution cryo-EM map of a protein assembly improves the accuracy of the fitting
    Joseph, Agnel P.
    Swapna, Lakshmipuram S.
    Rakesh, Ramachandran
    Srinivasan, Narayanaswamy
    JOURNAL OF STRUCTURAL BIOLOGY, 2016, 195 (03) : 294 - 305
  • [47] A New Algorithm for Improving the Resolution of Cryo-EM Density Maps
    Hirsch, Michael
    Schoelkopf, Bernhard
    Habeck, Michael
    RESEARCH IN COMPUTATIONAL MOLECULAR BIOLOGY, PROCEEDINGS, 2010, 6044 : 174 - 188
  • [48] Cryo-EM single-particle structure refinement and map calculation using Servalcat
    Yamashita, Keitaro
    Palmer, Colin M.
    Burnley, Tom
    Murshudov, Garib N.
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2021, 77 : 1282 - 1291
  • [49] Fast and accurate defocus modulation for improved tunability of cryo-EM experiments
    Danev, Radostin
    Iijima, Hirofumi
    Matsuzaki, Mizuki
    Motoki, Sohei
    IUCRJ, 2020, 7 : 566 - 574
  • [50] Cryo-EM Map-Based Model Validation Using the False Discovery Rate Approach
    Olek, Mateusz
    Joseph, Agnel Praveen