Accurate model annotation of a near-atomic resolution cryo-EM map

被引:88
|
作者
Hryc, Corey F. [1 ]
Chen, Dong-Hua [2 ,6 ]
Afonine, Pavel V. [3 ]
Jakana, Joanita [2 ]
Wang, Zhao [2 ]
Haase-Pettingell, Cameron [4 ]
Jiang, Wen [5 ]
Adams, Paul D. [3 ]
King, Jonathan A. [4 ]
Schmid, Michael F. [1 ,2 ]
Chiu, Wah [1 ,2 ]
机构
[1] Baylor Coll Med, Grad Program Struct & Computat Biol & Mol Biophys, Houston, TX 77030 USA
[2] Baylor Coll Med, Verna & Marrs McLean Dept Biochem & Mol Biol, Natl Ctr Macromol Imaging, Houston, TX 77030 USA
[3] Lawrence Berkeley Natl Lab, Molr Biophys & Integrated Bioimaging Div, Berkeley, CA 94720 USA
[4] MIT, Dept Biol, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[5] Purdue Univ, Dept Biol Sci, W Lafayette, IN 47907 USA
[6] Stanford Univ, Dept Biol Struct, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
cryo-EM; P22; model; structure; annotation; PHAGE-P22 COAT PROTEIN; ELECTRON CRYSTALLOGRAPHY; VALIDATION; MICROSCOPY; RECONSTRUCTION;
D O I
10.1073/pnas.1621152114
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electron cryomicroscopy (cryo-EM) has been used to determine the atomic coordinates (models) from density maps of biological assemblies. These models can be assessed by their overall fit to the experimental data and stereochemical information. However, these models do not annotate the actual density values of the atoms nor their positional uncertainty. Here, we introduce a computational procedure to derive an atomic model from a cryo-EM map with annotated metadata. The accuracy of such a model is validated by a faithful replication of the experimental cryo-EM map computed using the coordinates and associated metadata. The functional interpretation of any structural features in the model and its utilization for future studies can be made in the context of its measure of uncertainty. We applied this protocol to the 3.3-angstrom map of the mature P22 bacteriophage capsid, a large and complex macromolecular assembly. With this protocol, we identify and annotate previously undescribed molecular interactions between capsid subunits that are crucial to maintain stability in the absence of cementing proteins or cross-linking, as occur in other bacteriophages.
引用
收藏
页码:3103 / 3108
页数:6
相关论文
共 50 条
  • [31] Tools for the cryo-EM gold rush: going from the cryo-EM map to the atomistic model
    Kim, Doo Nam
    Sanbonmatsu, Karissa Y.
    BIOSCIENCE REPORTS, 2017, 37
  • [32] Single-particle cryo-EM at atomic resolution
    Nakane, Takanori
    Kotecha, Abhay
    Sente, Andrija
    McMullan, Greg
    Masiulis, Simonas
    Brown, Patricia M. G. E.
    Grigoras, Ioana T.
    Malinauskaite, Lina
    Malinauskas, Tomas
    Miehling, Jonas
    Uchanski, Tomasz
    Yu, Lingbo
    Karia, Dimple
    Pechnikova, Evgeniya V.
    de Jong, Erwin
    Keizer, Jeroen
    Bischoff, Maarten
    McCormack, Jamie
    Tiemeijer, Peter
    Hardwick, Steven W.
    Chirgadze, Dimitri Y.
    Murshudov, Garib
    Aricescu, A. Radu
    Scheres, Sjors H. W.
    NATURE, 2020, 587 (7832) : 152 - +
  • [33] Single-particle cryo-EM at atomic resolution
    Takanori Nakane
    Abhay Kotecha
    Andrija Sente
    Greg McMullan
    Simonas Masiulis
    Patricia M. G. E. Brown
    Ioana T. Grigoras
    Lina Malinauskaite
    Tomas Malinauskas
    Jonas Miehling
    Tomasz Uchański
    Lingbo Yu
    Dimple Karia
    Evgeniya V. Pechnikova
    Erwin de Jong
    Jeroen Keizer
    Maarten Bischoff
    Jamie McCormack
    Peter Tiemeijer
    Steven W. Hardwick
    Dimitri Y. Chirgadze
    Garib Murshudov
    A. Radu Aricescu
    Sjors H. W. Scheres
    Nature, 2020, 587 : 152 - 156
  • [34] Interpreting the cryo-EM map
    Rosenthal, Peter B.
    IUCRJ, 2019, 6 : 3 - 4
  • [35] Cryo-EM goes atomic
    Rita Strack
    Nature Methods, 2020, 17 : 1175 - 1175
  • [36] Cryo-EM goes atomic
    Strack, Rita
    NATURE METHODS, 2020, 17 (12) : 1175 - 1175
  • [37] Atomic resolution structure determination by the cryo-EM method MicroED
    Gonen, Tamir
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2017, 73 : A196 - A196
  • [38] Atomic-resolution protein structure determination by cryo-EM
    Yip, Ka Man
    Fischer, Niels
    Paknia, Elham
    Chari, Ashwin
    Stark, Holger
    NATURE, 2020, 587 (7832) : 157 - +
  • [39] Atomic resolution structure determination by the cryo-EM method MicroED
    Liu, Shian
    Hattne, Johan
    Reyes, Francis E.
    Sanchez-Martinez, Silvia
    de la Cruz, M. Jason
    Shi, Dan
    Gonen, Tamir
    PROTEIN SCIENCE, 2017, 26 (01) : 8 - 15
  • [40] Atomic resolution structure determination by cryo-EM - where are the limits?
    Stark, Holger
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : C9 - C9