Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT

被引:13
作者
Liu, Han [1 ]
Zhuang, Tingliang [1 ]
Stephans, Kevin [1 ]
Videtic, Gregory [1 ]
Raithel, Stephen [1 ]
Djemil, Toufik [1 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Dept Radiat Oncol, Cleveland, OH 44195 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2015年 / 16卷 / 06期
关键词
lung SBRT; IMRT; dose calculation; Monte Carlo; pencil beam; BODY RADIATION-THERAPY; HYPOFRACTIONATED STEREOTACTIC RADIOTHERAPY; CLINICAL-EVALUATION; PHOTON BEAMS; CANCER; ALGORITHM; VERIFICATION; ENERGY; VMC;
D O I
10.1120/jacmp.v16i6.5514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy, early treatment plans were based on a simpler dose calculation algorithm, the pencil beam (PB) calculation. Because these patients had the longest treatment follow-up, identifying dose differences between the PB calculated dose and Monte Carlo calculated dose is clinically important for understanding of treatment outcomes. Previous studies found significant dose differences between the PB dose calculation and more accurate dose calculation algorithms, such as convolution-based or Monte Carlo (MC), mostly for three-dimensional conformal radiotherapy (3D CRT) plans. The aim of this study is to investigate whether these observed dose differences also exist for intensity-modulated radiotherapy (IMRT) plans for both centrally and peripherally located tumors. Seventy patients (35 central and 35 peripheral) were retrospectively selected for this study. The clinical IMRT plans that were initially calculated with the PB algorithm were recalculated with the MC algorithm. Among these paired plans, dosimetric parameters were compared for the targets and critical organs. When compared to MC calculation, PB calculation overestimated doses to the planning target volumes (PTVs) of central and peripheral tumors with different magnitudes. The doses to 95% of the central and peripheral PTVs were overestimated by 9.7% +/- 5.6% and 12.0% +/- 7.3%, respectively. This dose overestimation did not affect doses to the critical organs, such as the spinal cord and lung. In conclusion, for NSCLC treated with IMRT, dose differences between the PB and MC calculations were different from that of 3D CRT. No significant dose differences in critical organs were observed between the two calculations.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 17 条
[1]   Dosimetric errors during treatment of centrally located lung tumors with stereotactic body radiation therapy: Monte Carlo evaluation of tissue inhomogeneity corrections [J].
Altunbas, Cem ;
Kavanagh, Brian ;
Dzingle, Wayne ;
Stuhr, Kelly ;
Gaspar, Laurie ;
Miften, Moyed .
MEDICAL DOSIMETRY, 2013, 38 (04) :436-441
[2]  
[Anonymous], 0813 RTOG
[3]   Correlation of dose computed using different algorithms with local control following stereotactic ablative radiotherapy (SABR)-based treatment of non-small-cell lung cancer [J].
Chetty, Indrin J. ;
Devpura, Suneetha ;
Liu, Dezhi ;
Chen, Daiquan ;
Li, Haisen ;
Wen, Ning ;
Kumar, Sanath ;
Fraser, Correen ;
Siddiqui, M. Salim ;
Ajlouni, Munther ;
Movsas, Benjamin .
RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) :498-504
[4]   Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm [J].
Fippel, M .
MEDICAL PHYSICS, 1999, 26 (08) :1466-1475
[5]   Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning [J].
Fragoso, Margarida ;
Wen, Ning ;
Kumar, Sanath ;
Liu, Dezhi ;
Ryu, Samuel ;
Movsas, Benjamin ;
Munther, Ajlouni ;
Chetty, Indrin J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) :4445-4464
[6]   3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC) [J].
Kawrakow, I ;
Fippel, M ;
Friedrich, K .
MEDICAL PHYSICS, 1996, 23 (04) :445-457
[7]   Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams [J].
Kuenzler, Thomas ;
Fotina, Irina ;
Stock, Markus ;
Georg, Dietmar .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (24) :7363-7377
[8]   Stereotactic body radiation therapy of early-stage non-small-cell lung carcinoma: Phase I study [J].
McGarry, RC ;
Papiez, L ;
Williams, M ;
Whitford, T ;
Timmerman, RD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (04) :1010-1015
[9]   Hypofractionated stereotactic radiotherapy for medically inoperable stage I non-small cell lung cancer - report on clinical outcome and dose to critical organs [J].
Ng, Alice W. Y. ;
Tung, Stewart Y. ;
Wong, Victy Y. W. .
RADIOTHERAPY AND ONCOLOGY, 2008, 87 (01) :24-28
[10]   Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage I non-small cell lung cancer: Updated results of 257 patients in a Japanese multi-institutional study [J].
Onishi, Hiroshi ;
Shirato, Hiroki ;
Nagata, Yasushi ;
Hiraoka, Masahiro ;
Fujino, Masaharu ;
Gomi, Kotaro ;
Niibe, Yuzuru ;
Karasawa, Katsuyuki ;
Hayakawa, Kazushige ;
Takai, Yoshihiro ;
Kimura, Tomoki ;
Takeda, Atsuya ;
Ouchi, Atsushi ;
Hareyama, Masato ;
Kokubo, Masaki ;
Hara, Ryusuke ;
Itami, Jun ;
Yamada, Kazunari ;
Araki, Tsutomu .
JOURNAL OF THORACIC ONCOLOGY, 2007, 2 (07) :S94-S100