A Novel Real-Time Loop-Mediated Isothermal Amplification Combined with Immunomagnetic Beads Separation and Ethidium Bromide Monoazide Treatment for Rapid and Ultrasensitive Detection of Viable Escherichia coli O157:H7 in Milk

被引:15
作者
Chen, Hu [1 ]
Li, Ya-Ke [1 ]
Zhang, Tian-Tian [1 ]
Bi, Yan [1 ]
Shu, Mei [1 ]
Zhong, Chan [1 ]
Tang, Kai-Jie [1 ]
Wu, Guo-Ping [1 ]
机构
[1] Jiangxi Agr Univ, Coll Food Sci & Engn, Nanchang 330045, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
E. coli O157:H7; Real-time loop-mediated isothermal amplification (Rti-LAMP); Immunomagnetic beads separation (IMS); Gly-HCl elution; Ethidium bromide monoazide (EMA); MULTIPLEX PCR ASSAY; LISTERIA-MONOCYTOGENES; EFFICIENT ENRICHMENT; PMA; SALMONELLA; LAMP; BACTERIA; CELLS; DNA;
D O I
10.1007/s12161-020-01932-y
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In this study, a real-time loop-mediated isothermal amplification (Rti-LAMP) combined with immunomagnetic beads separation (IMS) and ethidium bromide monoazide (EMA) treatment was developed for the rapid and ultrasensitive detection of viable Escherichia coli (E. coli) O157:H7 in milk without enrichment. Polyclonal antibodies against E. coli O157:H7 flagellum and specific immunomagnetic beads (IMBs) were prepared. The capture efficiency of target bacteria was more than 95% by adding 50 mu L of prepared IMBs into 1 mL of E. coli sample for incubation at 37 degrees C for 20 min. Then, Gly-HCl buffer (0.2 M, pH 2.2) was a key to the effective eluting and separating of bacteria from IMB-bacterial complexes. The eluted bacteria were resuspended with 20 mu L TZ lysing solution and boiled at 99.5 degrees C for 10 min, as a DNA template of Rti-LAMP. The development of IMS-Rti-LAMP assay could specifically detect viable E. coli O157:H7 as low as 2.7 CFU/mL in pure culture. Furthermore, the optimum volume for detection of E. coli O157:H7 in milk was 1 mL of the sample by IMS-Rti-LAMP assay. Before Gly-HCl elution, 4 mu g/mL of EMA was used to treat bacterial cells which significantly inhibited DNA amplification derived from dead cells in Rti-LAMP. The limit of detection (LOD) of viable E. coli O157:H7 in milk was 6 CFU/mL by the IMS-EMA-Rti-LAMP, and the whole assay could be completed in 4 h. The development of IMS-EMA-Rti-LAMP assay was a rapid, ultrasensitive, and specific detection of viable E. coli O157:H7 in milk without enrichment.
引用
收藏
页码:944 / 956
页数:13
相关论文
共 50 条
  • [1] A Novel Real-Time Loop-Mediated Isothermal Amplification Combined with Immunomagnetic Beads Separation and Ethidium Bromide Monoazide Treatment for Rapid and Ultrasensitive Detection of Viable Escherichia coli O157:H7 in Milk
    Hu Chen
    Ya-Ke Li
    Tian-Tian Zhang
    Yan Bi
    Mei Shu
    Chan Zhong
    Kai-Jie Tang
    Guo-Ping Wu
    Food Analytical Methods, 2021, 14 : 944 - 956
  • [2] Quantification and Discrimination of Viable and Dead Escherichia coli O157:H7 Cells from Chicken Without Enrichment by Ethidium Bromide Monoazide Real-time Loop-Mediated Isothermal Amplification
    Zhao, Yuan Yang
    Tang, Kai Jie
    Zhang, Tian Tian
    Gao, Yan Yan
    Lin, Li Ping
    Wu, Guo Ping
    FOOD ANALYTICAL METHODS, 2018, 11 (05) : 1257 - 1266
  • [3] Rapid Detection of Viable Escherichia coli O157 by Coupling Propidium Monoazide with Loop-Mediated Isothermal Amplification
    Zhao, Xihong
    Wang, Jun
    Forghani, Fereidoun
    Park, Joong-Hyun
    Park, Myoung-Su
    Seo, Kun-Ho
    Oh, Deog-Hwan
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2013, 23 (12) : 1708 - 1716
  • [4] Real-time loop-mediated isothermal amplification assays combined with ethidium monoazide bromide and bentonite coated activated carbon for rapid and sensitive detection of viable Escherichia coli O157:H7 from milk without enrichment
    Zhang, Tian T.
    Zhong, Chan
    Shu, Mei
    Wu, Xin
    Chen, Hu
    Lin, Li P.
    Wu, Guo P.
    JOURNAL OF FOOD SAFETY, 2019, 39 (05)
  • [5] Detection of viable Escherichia coli O157:H7 by ethidium monoazide real-time PCR
    Wang, L.
    Li, Y.
    Mustapha, A.
    JOURNAL OF APPLIED MICROBIOLOGY, 2009, 107 (05) : 1719 - 1728
  • [6] Rapid and Specific Detection of Escherichia coli O157:H7 in Ground Beef Using Immunomagnetic Separation Combined with Loop-Mediated Isothermal Amplification
    Qin, Yu
    Puthiyakunnon, Santhosh
    Zhang, Yiduo
    Wu, Xianbo
    Boddu, Swapna
    Luo, Binde
    Fan, Hongying
    POLISH JOURNAL OF FOOD AND NUTRITION SCIENCES, 2018, 68 (02) : 115 - 123
  • [7] Viable but Nonculturable Escherichia coli O157:H7 and Salmonella enterica in Fresh Produce: Rapid Determination by Loop-Mediated Isothermal Amplification Coupled with a Propidium Monoazide Treatment
    Han, Lu
    Wang, Kaidi
    Ma, Lina
    Delaquis, Pascal
    Bach, Susan
    Feng, Jinsong
    Lu, Xiaonan
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2020, 86 (07)
  • [8] Real-time recombinase-aided amplification with improved propidium monoazide for the rapid detection of viable Escherichia coli O157:H7 in milk
    Mu, Dan
    Zhou, Donggen
    Xie, Guoyang
    Liu, Ju
    Wang, Zhengzheng
    Xiong, Qin
    Xu, Hengyi
    JOURNAL OF DAIRY SCIENCE, 2022, 105 (02) : 1028 - 1038
  • [9] Detection of viable Escherichia coli O157:H7 in ground beef by propidium monoazide real-time PCR
    Liu, Yarui
    Mustapha, Azlin
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2014, 170 : 48 - 54
  • [10] Triplex immunomagnetic separation combined with loop-mediated isothermal amplification on a microfluidic chip for simultaneous visual detection of Escherichia coli O157:H7, Salmonella enteritidis and Staphylococcus aureus in milk
    Wang, Fucheng
    Ye, Fangyu
    Tang, Wei
    Wang, Quan
    You, Chenye
    Yu, Haiyang
    Zhou, Xin
    Han, Xiangan
    Jiang, Wei
    FOOD CONTROL, 2024, 165