On the equivalence and differences between laser Doppler flowmetry and laser speckle contrast analysis

被引:40
作者
Fredriksson, Ingemar [1 ,2 ]
Larsson, Marcus [1 ]
机构
[1] Linkoping Univ, Dept Biomed Engn, S-58185 Linkoping, Sweden
[2] Perimed AB, Datavagen 9A, S-17543 Jarfalla, Sweden
基金
瑞典研究理事会;
关键词
laser speckle imaging; microcirculation; optical properties; perfusion; tissue model; DYNAMIC LIGHT-SCATTERING; HUMAN SKIN; PERFUSION; TISSUE; MEDIA; FLOW; FLUCTUATIONS;
D O I
10.1117/1.JBO.21.12.126018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Laser Doppler flowmetry (LDF) and laser speckle contrast analysis (LASCA) both utilize the spatiotemporal properties of laser speckle patterns to assess microcirculatory blood flow in tissue. Although the techniques analyze the speckle pattern differently, there is a close relationship between them. We present a theoretical overview describing how the LDF power spectrum and the LASCA contrast can be calculated from each other, and how both these can be calculated from an optical Doppler spectrum containing various degrees of Doppler shifted light. The theoretical relationships are further demonstrated using time-resolved speckle simulations. A wide range of Monte Carlo simulated tissue models is then used to show how perfusion estimates for LDF and LASCA are affected by changes in blood concentration and speed distribution, as well as by geometrical and optical properties. We conclude that perfusion estimates from conventional single exposure time LASCA are in general more sensitive to changes in optical and geometrical properties and are less accurate in the prediction of real perfusion changes, especially speed changes. Since there is a theoretical one-to-one relationship between Doppler power spectrum and contrast, one can conclude that those drawbacks with the LASCA technique can be overcome using a multiple exposure time setup. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A comparison study of cerebral autoregulation assessed with transcranial Doppler and cortical laser Doppler flowmetry
    Zweifel, Christian
    Czosnyka, Marek
    Lavinio, Andrea
    Castellani, Gianluca
    Kim, Dong-Joo
    Carrera, Emmanuel
    Pickard, John D.
    Kirkpatrick, Peter J.
    Smielewski, Peter
    NEUROLOGICAL RESEARCH, 2010, 32 (04) : 425 - 428
  • [22] Laser doppler flowmetry in the hyperbaric environment
    G. Litscher
    K. O. Möller
    B. Ratzenhofer-komenda
    G. Schwarz
    T. Koop
    H. Kovac
    Lasers in Medical Science, 1997, 12 : 342 - 346
  • [23] Laser Doppler flowmetry in the hyperbaric environment
    Litscher, G
    Moller, KO
    RatzenhoferKomenda, B
    Schwarz, G
    Koop, T
    Kovac, H
    LASERS IN MEDICAL SCIENCE, 1997, 12 (04) : 342 - 346
  • [24] Perfusion of Ischemic Brain in Young and Aged Animals A Laser Speckle Flowmetry Study
    Manwani, Bharti
    Friedler, Brett
    Verma, Rajkumar
    Venna, Venugopal Reddy
    McCullough, Louise D.
    Liu, Fudong
    STROKE, 2014, 45 (02) : 571 - 578
  • [25] Assessment of bone vascularity in the anterior mandible using laser Doppler flowmetry
    Verdonck, Henk W. D.
    Meijer, Gert J.
    Kessler, Peter
    Nieman, Fred H.
    de Baat, Cees
    Stoelinga, Paul J. W.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (02) : 140 - 144
  • [26] EVALUATION OF GINGIVAL VASCULARISATION USING LASER DOPPLER FLOWMETRY
    Vitez, B.
    Todea, C.
    Velescu, A.
    Sipos, C.
    HIGH-END MEDICINE BASED ON LASER AND BIOTECHNOLOGIES, 2016, 9670
  • [27] Laser Speckle Contrast Imaging for Monitoring Changes in Microvascular Blood Flow
    Ambrus, Rikard
    Strandby, Rune B.
    Svendsen, Lars Bo
    Achiam, Michael P.
    Steffensen, John F.
    Svendsen, Morten Bo Sondergaard
    EUROPEAN SURGICAL RESEARCH, 2016, 56 (3-4) : 87 - 96
  • [28] Laser power modulation with wavelength stabilization in multiple exposure laser speckle contrast analysis
    Smausz, Tomi
    Zoelei, Daniel
    Hopp, Bela
    SPECKLE 2012: V INTERNATIONAL CONFERENCE ON SPECKLE METROLOGY, 2012, 8413
  • [29] Detrended fluctuation analysis of laser Doppler flowmetry time series
    Esen, Ferhan
    Aydin, Guelsuen Soenmez
    Esen, Hamza
    MICROVASCULAR RESEARCH, 2009, 78 (03) : 314 - 318
  • [30] Laser speckle contrast imaging: theoretical and practical limitations
    Briers, David
    Duncan, Donald D.
    Hirst, Evan
    Kirkpatrick, Sean J.
    Larsson, Marcus
    Steenbergen, Wiendelt
    Stromberg, Tomas
    Thompson, Oliver B.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (06)