Evaluation of 2-point, 3-point, and 6-point Dixon magnetic resonance imaging with flexible echo timing for muscle fat quantification

被引:64
作者
Grimm, Alexandra [1 ]
Meyer, Heiko [2 ]
Nickel, Marcel D. [2 ]
Nittka, Mathias [2 ]
Raithel, Esther [2 ]
Chaudry, Oliver [1 ]
Friedberger, Andreas [1 ]
Uder, Michael [3 ]
Kemmler, Wolfgang [1 ]
Quick, Harald H. [1 ,4 ,5 ]
Engelke, Klaus [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Inst Med Phys, Henkestr 91, D-91052 Erlangen, Germany
[2] Siemens Healthcare GmbH, Diagnost Imaging Magnet Resonance Prod Definit &, Allee Roethelheimpk 2, Erlangen, Germany
[3] Univ Hosp Erlangen, Inst Radiol, Ulmenweg 18, Erlangen, Germany
[4] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Kokereiallee 7, Essen, Germany
[5] Univ Hosp Essen, High Field & Hybrid MR Imaging, Hufelandstr 55, Essen, Germany
关键词
Magnetic resonance imaging; Dixon; Fat quantification; Sarcopenia; Muscle; Thigh; ADIPOSE-TISSUE; LIVER FAT; WATER; SPECTROSCOPY; MRI; ACQUISITION; SEPARATION;
D O I
10.1016/j.ejrad.2018.04.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to evaluate and compare 2-point (2pt), 3-point (3pt), and 6-point (6pt) Dixon magnetic resonance imaging (MRI) sequences with flexible echo times (TE) to measure proton density fat fraction (PDFF) within muscles. Two subject groups were recruited (G1: 23 young and healthy men, 31 +/- 6 years; G2: 50 elderly men, sarcopenic, 77 +/- 5 years). A 3-T MRI system was used to perform Dixon imaging on the left thigh. PDFF was measured with six Dixon prototype sequences: 2pt, 3pt, and 6pt sequences once with optimal TEs (in-and opposed-phase echo times), lower resolution, and higher bandwidth (optTE sequences) and once with higher image resolution (highRes sequences) and shortest possible TE, respectively. Intra-fascia PDFF content was determined. To evaluate the comparability among the sequences, Bland-Altman analysis was performed. The highRes 6pt Dixon sequences served as reference as a high correlation of this sequence to magnetic resonance spectroscopy has been shown before. The PDFF difference between the highRes 6pt Dixon sequence and the optTE 6pt, both 3pt, and the optTE 2pt was low (between 2.2% and 4.4%), however, not to the highRes 2pt Dixon sequence (33%). For the optTE sequences, difference decreased with the number of echoes used. In conclusion, for Dixon sequences with more than two echoes, the fat fraction measurement was reliable with arbitrary echo times, while for 2pt Dixon sequences, it was reliable with dedicated in-and opposed-phase echo timing.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 30 条
  • [1] Longitudinal 2-point dixon muscle magnetic resonance imaging in becker muscular dystrophy
    Bonati, Ulrike
    Schmid, Maurice
    Hafner, Patricia
    Haas, Tanja
    Bieri, Oliver
    Gloor, Monika
    Fischmann, Arne
    Fischer, Dirk
    MUSCLE & NERVE, 2015, 51 (06) : 918 - 921
  • [2] A COMPARISON BETWEEN 6-POINT DIXON MRI AND MR SPECTROSCOPY TO QUANTIFY MUSCLE FAT IN THE THIGH OF SUBJECTS WITH SARCOPENIA
    Grimm, A.
    Meyer, H.
    Nickel, M. D.
    Nittka, M.
    Raithel, E.
    Chaudry, O.
    Friedberger, A.
    Uder, M.
    Kemmler, W.
    Engelke, K.
    Quick, H. H.
    JOURNAL OF FRAILTY & AGING, 2019, 8 (01) : 21 - 26
  • [3] A Comparison Between 6-Point Dixon Mri and Mr Spectroscopy to Quantify Muscle fat in the Thigh of Subjects with Sarcopenia
    A. Grimm
    H. Meyer
    M. D. Nickel
    M. Nittka
    E. Raithel
    O. Chaudry
    A. Friedberger
    M. Uder
    W. Kemmler
    K. Engelke
    H. H. Quick
    The Journal of Frailty & Aging, 2019, 8 : 21 - 26
  • [4] Comparison of Multi-Echo Dixon Methods with Volume Interpolated Breath-Hold Gradient Echo Magnetic Resonance Imaging in Fat-Signal Fraction Quantification of Paravertebral Muscle
    Yoo, Yeon Hwa
    Kim, Hak-Sun
    Lee, Young Han
    Yoon, Choon-Sik
    Paek, Mun Young
    Yoo, Hanna
    Kannengiesser, Stephan
    Chung, Tae-Sub
    Song, Ho-Taek
    Suh, Jin-Suck
    Kim, Sungjun
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (05) : 1086 - 1095
  • [5] Quantitative assessment of fatty infiltration and muscle volume of the rotator cuff muscles using 3-dimensional 2-point Dixon magnetic resonance imaging
    Matsumura, Noboru
    Oguro, Sota
    Okuda, Shigeo
    Jinzaki, Masahiro
    Matsumoto, Morio
    Nakamura, Masaya
    Nagura, Takeo
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (10) : E309 - E318
  • [6] Direct water and fat determination in two-point Dixon imaging with flexible echo times
    Rambow, Olen
    Hazle, John
    Clark, John
    Ma, Jingfei
    MEDICAL PHYSICS, 2013, 40 (11)
  • [7] Improved T1, Contrast Concentration, and Pharmacokinetic Parameter Quantification in the Presence of Fat with Two-Point Dixon for Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Le, Yuan
    Dale, Brian
    Akisik, Fatih
    Koons, Karen
    Lin, Chen
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1677 - 1684
  • [8] Quantification of Fatty Degeneration Within the Supraspinatus Muscle by Using a 2-Point Dixon Method on 3-T MRI
    Nozaki, Taiki
    Tasaki, Atsushi
    Horiuchi, Saya
    Osakabe, Chiharu
    Ohde, Sachiko
    Saida, Yukihisa
    Yoshioka, Hiroshi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) : 116 - 122
  • [9] Evaluation of six-point modified dixon and magnetic resonance spectroscopy for fat quantification: a fat–water–iron phantom study
    Fukuzawa K.
    Hayashi T.
    Takahashi J.
    Yoshihara C.
    Tano M.
    Kotoku J.
    Saitoh S.
    Radiological Physics and Technology, 2017, 10 (3) : 349 - 358
  • [10] Quantification of pancreas fat on dual-energy computed tomography: comparison with six-point Dixon magnetic resonance imaging
    Fumi Kameda
    Masahiro Tanabe
    Hideko Onoda
    Mayumi Higashi
    Shoko Ariyoshi
    Kenichiro Ihara
    Etsushi Iida
    Matakazu Furukawa
    Munemasa Okada
    Katsuyoshi Ito
    Abdominal Radiology, 2020, 45 : 2779 - 2785