An amperometric biosensor for glucose detection from glucose oxidase immobilized in polyaniline-polyvinylsulfonate-potassium ferricyanide film

被引:21
|
作者
Arslan, Fatma [1 ]
Beskan, Umut [2 ]
机构
[1] Gazi Univ, Fac Sci, Dept Chem, Ankara, Turkey
[2] Gazi Univ, Inst Sci, Dept Chem, Ankara, Turkey
关键词
amperometric biosensor; ferricyanide; glucose; polyaniline; polyvinylsulphonate; POLYPYRROLE FILM; ELECTRODE; FERROCENE; MEDIATOR; SENSORS;
D O I
10.3109/21691401.2013.812650
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this study, a novel amperometric glucose biosensor with immobilization of glucose oxidase on electrochemically polymerized polyaniline-polyvinylsulphonate-potassium ferricyanide (Pani-Pvs-Fc) films has been accomplished via the entrapment technique. Potassium ferricyanide was used as the mediator. Determination of glucose was carried out by the oxidation of potassium ferrocyanide at 0.3 V vs. Ag/AgCl. The effects of pH and temperature were investigated, and the optimum pH value was found to be 7.5. The storage stability and the operational stability of the enzyme electrode were also studied.
引用
收藏
页码:284 / 288
页数:5
相关论文
共 50 条
  • [41] Silver Nanoparticles as a Glucose Oxidase Immobilization Matrix for Amperometric Glucose Biosensor Construction
    Hsu, Fu-Yin
    Yu, Ding-Syuan
    Chang, Jung-Che
    Chuang, Chia-Lin
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (06) : 756 - 760
  • [42] Amperometric detection of glucose with glucose oxidase absorbed on porous nanocrystalline TiO2 film
    Li, QW
    Luo, GA
    Feng, J
    Zhou, Q
    Zhang, L
    Zhu, YF
    ELECTROANALYSIS, 2001, 13 (05) : 413 - 416
  • [43] AMPEROMETRIC GLUCOSE SENSORS BASED ON IMMOBILIZED GLUCOSE-OXIDASE POLYQUINONE SYSTEM
    KAKU, T
    KARAN, HI
    OKAMOTO, Y
    ANALYTICAL CHEMISTRY, 1994, 66 (08) : 1231 - 1235
  • [44] Enzymatically synthesized polyaniline layer for extension of linear detection region of amperometric glucose biosensor
    Kausaite-Minkstimiene, Asta
    Mazeiko, Viktor
    Ramanaviciene, Almira
    Ramanavicius, Arunas
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 790 - 797
  • [45] DETECTION OF GLUCOSE BY USING IMMOBILIZED GLUCOSE-OXIDASE
    MANOCHIOPINIJ, S
    SAPSAMARNWONG, C
    SIRISALI, K
    JOURNAL OF THE SCIENCE SOCIETY OF THAILAND, 1985, 11 (02): : 79 - 91
  • [46] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 47 - MICR
  • [47] Preparation of an Amperometric Glucose Biosensor on Polyaniline-Coated Graphite
    Neupane, Shova
    Bhusal, Suresh
    Subedi, Vivek
    Nakarmi, Krishna Badan
    Gupta, Dipak Kumar
    Yadav, Ram Jeewan
    Yadav, Amar Prasad
    JOURNAL OF SENSORS, 2021, 2021
  • [48] Amperometric Glucose Biosensor Based on Mediated Electron Transfer between Immobilized Glucose Oxidase and Plasma-polymerized Thin Film of Dimethylaminomethylferrocene on Sputtered Gold Electrode
    Yoshihiro Kase
    Hitoshi Muguruma
    Analytical Sciences, 2004, 20 : 1143 - 1146
  • [49] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 9 (01) : 95 - 104
  • [50] Amperometric glucose biosensor based on mediated electron transfer between immobilized glucose oxidase and plasma-polymerized thin film of dimethylaminomethylferrocene on sputtered gold electrode
    Kase, Y
    Muguruma, H
    ANALYTICAL SCIENCES, 2004, 20 (08) : 1143 - 1146