摘要
In this study, a novel amperometric glucose biosensor with immobilization of glucose oxidase on electrochemically polymerized polyaniline-polyvinylsulphonate-potassium ferricyanide (Pani-Pvs-Fc) films has been accomplished via the entrapment technique. Potassium ferricyanide was used as the mediator. Determination of glucose was carried out by the oxidation of potassium ferrocyanide at 0.3 V vs. Ag/AgCl. The effects of pH and temperature were investigated, and the optimum pH value was found to be 7.5. The storage stability and the operational stability of the enzyme electrode were also studied.
引用
收藏
页码:284 / 288
页数:5
相关论文
共 50 条
  • [31] AMPEROMETRIC GLUCOSE SENSORS BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN NAFION
    RISHPON, J
    GOTTESFELD, S
    CAMPBELL, C
    DAVEY, J
    ZAWODZINSKI, TA
    ELECTROANALYSIS, 1994, 6 (01) : 17 - 21
  • [32] GLUCOSE OXIDASE "WIRED" WITH POTASSIUM FERRICYANIDE POLYPYRROLE FILMS
    Amarandei, Cristina-Andreea
    Ungureanu, Eleonora-Mihaela
    Leonida, Mihaela
    Andronescu, Corina
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2012, 74 (03): : 19 - 36
  • [33] Glucose oxidase immobilized PANI cladding modified fiber optic intrinsic biosensor for detection of glucose
    Pahurkar, V. G.
    Tamgadge, Y. S.
    Gambhire, A. B.
    Muley, G. G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 362 - 368
  • [34] Condensation a-Cyclodextrin Polymer Membrane with Covalently Immobilized Glucose Oxidase and Molecularly Included Mediator for Amperometric Glucose Biosensor
    Kutner, W.
    Wu, H.
    Kadish, K. M.
    Journal of Microcolumn Separation, 768
  • [35] Amperometric glucose biosensor based on lipid film
    Wu, ZY
    Wang, BQ
    Dong, SJ
    Wang, EK
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4): : 143 - 147
  • [36] An amperometric biosensor for fish freshness detection from xanthine oxidase immobilized in polypyrrole-polyvinylsulphonate film
    Dolmaci, Nezaket
    Cete, Servet
    Arslan, Fatma
    Yasar, Ahmet
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2012, 40 (04): : 275 - 279
  • [37] PEG-modified glucose oxidase immobilized on a PVA cryogel membrane for amperometric biosensor applications
    Doretti, L
    Ferrara, D
    Gattolin, P
    Lora, S
    Schiavon, F
    Veronese, FM
    TALANTA, 1998, 45 (05) : 891 - 898
  • [38] Potassium ferricyanide mediated disposable biosensor for determination of maltose and glucose
    Ge, F
    Zhang, XE
    Zhang, ZP
    Zhang, XM
    ANALYTICAL LETTERS, 1998, 31 (03) : 383 - 394
  • [39] Amperometric glucose biosensor based on glucose oxidase-lectin biospecific interaction
    Zhang, Juanjuan
    Wang, Chengyan
    Chen, Shihong
    Yuan, Dehua
    Zhong, Xia
    ENZYME AND MICROBIAL TECHNOLOGY, 2013, 52 (03) : 134 - 140
  • [40] Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor
    Valdes-Ramirez, Gabriela
    Galicia, Laura
    MOLECULES, 2021, 26 (12):