An amperometric biosensor for glucose detection from glucose oxidase immobilized in polyaniline-polyvinylsulfonate-potassium ferricyanide film

被引:21
|
作者
Arslan, Fatma [1 ]
Beskan, Umut [2 ]
机构
[1] Gazi Univ, Fac Sci, Dept Chem, Ankara, Turkey
[2] Gazi Univ, Inst Sci, Dept Chem, Ankara, Turkey
关键词
amperometric biosensor; ferricyanide; glucose; polyaniline; polyvinylsulphonate; POLYPYRROLE FILM; ELECTRODE; FERROCENE; MEDIATOR; SENSORS;
D O I
10.3109/21691401.2013.812650
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this study, a novel amperometric glucose biosensor with immobilization of glucose oxidase on electrochemically polymerized polyaniline-polyvinylsulphonate-potassium ferricyanide (Pani-Pvs-Fc) films has been accomplished via the entrapment technique. Potassium ferricyanide was used as the mediator. Determination of glucose was carried out by the oxidation of potassium ferrocyanide at 0.3 V vs. Ag/AgCl. The effects of pH and temperature were investigated, and the optimum pH value was found to be 7.5. The storage stability and the operational stability of the enzyme electrode were also studied.
引用
收藏
页码:284 / 288
页数:5
相关论文
共 50 条
  • [1] An Amperometric Biosensor for Glucose Determination Prepared from Glucose Oxidase Immobilized in Polyaniline-Polyvinylsulfonate Film
    Arslan, Fatma
    Ustabas, Selvin
    Arslan, Halit
    SENSORS, 2011, 11 (08) : 8152 - 8163
  • [2] GLUCOSE BIOSENSOR USING GLUCOSE-OXIDASE IMMOBILIZED IN POLYANILINE
    PARENTE, AH
    MARQUES, ETA
    AZEVEDO, WM
    DINIZ, FB
    MELO, EHM
    FILHO, JLL
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1992, 37 (03) : 267 - 273
  • [3] IMMOBILIZATION OF GLUCOSE OXIDASE IN SILICA SOL-GEL FILM FOR APPLICATION TO BIOSENSOR AND AMPEROMETRIC DETERMINATION OF GLUCOSE
    Demirkiran, Nizamettin
    Ekinci, Ergun
    Asilturk, Meltem
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2012, 57 (04) : 1336 - 1339
  • [4] Glucose oxidase immobilized PANI cladding modified fiber optic intrinsic biosensor for detection of glucose
    Pahurkar, V. G.
    Tamgadge, Y. S.
    Gambhire, A. B.
    Muley, G. G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 362 - 368
  • [5] Amperometric glucose biosensor based on entrapment of glucose oxidase in a poly(3,4-ethylenedioxythiophene) film
    Nien, Po-Chin
    Tung, Tsai-Shih
    Ho, Kuo-Chuan
    ELECTROANALYSIS, 2006, 18 (13-14) : 1408 - 1415
  • [6] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [7] Amperometric glucose biosensor based on silver nanowires and glucose oxidase
    Wang, Lisha
    Gao, Xia
    Jin, Lingyan
    Wu, Qi
    Chen, Zhichun
    Lin, Xianfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 9 - 14
  • [8] An amperometric biosensor for fish freshness detection from xanthine oxidase immobilized in polypyrrole-polyvinylsulphonate film
    Dolmaci, Nezaket
    Cete, Servet
    Arslan, Fatma
    Yasar, Ahmet
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2012, 40 (04): : 275 - 279
  • [9] Enzymatically synthesized polyaniline layer for extension of linear detection region of amperometric glucose biosensor
    Kausaite-Minkstimiene, Asta
    Mazeiko, Viktor
    Ramanaviciene, Almira
    Ramanavicius, Arunas
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) : 790 - 797
  • [10] A New Biosensor for Glucose Based on Carbon Paste and Enzyme Immobilized onto the Polyaniline Film
    Stoces, Matej
    Kalcher, Kurt
    Svancara, Ivan
    Vytras, Karel
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (06): : 1917 - 1926