Inter-Observer, Intra-Observer and Intra-Individual Reliability of Uroflowmetry Tests in Aged Men: A Generalizability Theory Approach

被引:6
|
作者
Liu, Ying-Buh
Yang, Stephen S.
Hsieh, Cheng-Hsing
Lin, Chia-Da
Chang, Shang-Jen [1 ]
机构
[1] Buddhist Tzu Chi Gen Hosp, Div Urol, Taipei Branch, Taipei 231, Taiwan
关键词
intra-individual reliability; inter-observer reliability; uroflowmetry; intra-observer reliability; GUIDELINES; CURVES;
D O I
10.1111/luts.12022
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives To evaluate the inter-observer, intra-observer and intra-individual reliability of uroflowmetry and post-void residual urine (PVR) tests in adult men. Methods Healthy volunteers aged over 40 years were enrolled. Every participant underwent two sets of uroflowmetry and PVR tests with a 2-week interval between the tests. The uroflowmetry tests were interpreted by four urologists independently. Uroflowmetry curves were classified as bell-shaped, bell-shaped with tail, obstructive, restrictive, staccato, interrupted and tower-shaped and scored from 1 (highly abnormal) to 5 (absolutely normal). The agreements between the observers, interpretations and tests within individuals were analyzed using kappa statistics and intraclass correlation coefficients. Generalizability theory with decision analysis was used to determine how many observers, tests, and interpretations were needed to obtain an acceptable reliability (> 0.80). Results Of 108 volunteers, we randomly selected the uroflowmetry results from 25 participants for the evaluation of reliability. The mean age of the studied adults was 55.3 years. The intra-individual and intra-observer reliability on uroflowmetry tests ranged from good to very good. However, the inter-observer reliability on normalcy and specific type of flow pattern were relatively lower. In generalizability theory, three observers were needed to obtain an acceptable reliability on normalcy of uroflow pattern if the patient underwent uroflowmetry tests twice with one observation. Conclusions The intra-individual and intra-observer reliability on uroflowmetry tests were good while the inter-observer reliability was relatively lower. To improve inter-observer reliability, the definition of uroflowmetry should be clarified by the International Continence Society.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 33 条
  • [31] A comparative assessment of intra- and inter-observer repeatability of three widely used software packages forthe quantification of defect sizein stress myocardial perfusion scintigraphy
    Sachpekidis, Christos
    Kopp-Schneider, Annette
    Sachpekidis, Vasileios
    Moralidis, Efstratios
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2022, 25 (03) : 274 - 284
  • [32] Summary of meta-analyses of studies considering lesion size cut-off thresholds for the assessment of eligibility for FNAB and sonoelastography and inter- and intra-observer agreement in estimating the malignant potential of focal lesions of the thyroid gland
    Dobruch-Sobczak, Katarzyna
    Adamczewski, Zbigniew
    Dedecjus, Marek
    Lewinski, Andrzej
    Migda, Bartosz
    Ruchala, Marek
    Skowronska-Szczesniak, Anna
    Szczepanek-Parulska, Ewelina
    Zajkowska, Klaudia
    Zylka, Agnieszka
    JOURNAL OF ULTRASONOGRAPHY, 2022, 22 (89) : 130 - 135
  • [33] Do thoraco-lumbar spinal injuries classification systems exhibit lower inter- and intra-observer agreement than other fractures classifications? A comparison using fractures of the trochanteric area of the proximal femur as contrast model
    Urrutia, Julio
    Zamora, Tomas
    Klaber, Ianiv
    Carmona, Maximiliano
    Palma, Joaquin
    Campos, Mauricio
    Yurac, Ratko
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (04): : 859 - 864