Inter-Observer, Intra-Observer and Intra-Individual Reliability of Uroflowmetry Tests in Aged Men: A Generalizability Theory Approach

被引:6
|
作者
Liu, Ying-Buh
Yang, Stephen S.
Hsieh, Cheng-Hsing
Lin, Chia-Da
Chang, Shang-Jen [1 ]
机构
[1] Buddhist Tzu Chi Gen Hosp, Div Urol, Taipei Branch, Taipei 231, Taiwan
关键词
intra-individual reliability; inter-observer reliability; uroflowmetry; intra-observer reliability; GUIDELINES; CURVES;
D O I
10.1111/luts.12022
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives To evaluate the inter-observer, intra-observer and intra-individual reliability of uroflowmetry and post-void residual urine (PVR) tests in adult men. Methods Healthy volunteers aged over 40 years were enrolled. Every participant underwent two sets of uroflowmetry and PVR tests with a 2-week interval between the tests. The uroflowmetry tests were interpreted by four urologists independently. Uroflowmetry curves were classified as bell-shaped, bell-shaped with tail, obstructive, restrictive, staccato, interrupted and tower-shaped and scored from 1 (highly abnormal) to 5 (absolutely normal). The agreements between the observers, interpretations and tests within individuals were analyzed using kappa statistics and intraclass correlation coefficients. Generalizability theory with decision analysis was used to determine how many observers, tests, and interpretations were needed to obtain an acceptable reliability (> 0.80). Results Of 108 volunteers, we randomly selected the uroflowmetry results from 25 participants for the evaluation of reliability. The mean age of the studied adults was 55.3 years. The intra-individual and intra-observer reliability on uroflowmetry tests ranged from good to very good. However, the inter-observer reliability on normalcy and specific type of flow pattern were relatively lower. In generalizability theory, three observers were needed to obtain an acceptable reliability on normalcy of uroflow pattern if the patient underwent uroflowmetry tests twice with one observation. Conclusions The intra-individual and intra-observer reliability on uroflowmetry tests were good while the inter-observer reliability was relatively lower. To improve inter-observer reliability, the definition of uroflowmetry should be clarified by the International Continence Society.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 33 条
  • [21] Intra- and inter-observer reliability of implant positioning evaluation on a CT-based three-dimensional postoperative matching system for total knee arthroplasty
    Watanabe, Shotaro
    Akagi, Ryuichiro
    Shiko, Yuki
    Ono, Yoshimasa
    Kawasaki, Yohei
    Ohdera, Toshihiro
    Ohtori, Seiji
    Sasho, Takahisa
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [22] An evaluation of intra and inter observer reliability of the five used classification systems of tibial plateau fractures
    Koksal, Alper
    Abul, Kadir
    Cimen, Osman
    Mert, Muhammed
    Keskin, Abdi
    Kargin, Deniz
    ACTA ORTHOPAEDICA BELGICA, 2022, 88 (04): : 805 - 810
  • [23] Intra-and inter-observer variability of point of care ultrasound measurements to evaluate hemodynamic parameters in healthy volunteers
    Deborah Blanca
    Esther C. Schwarz
    Tycho Joan Olgers
    Ewoud ter Avest
    Nasim Azizi
    Hjalmar R. Bouma
    Jan Cornelis Ter Maaten
    The Ultrasound Journal, 15
  • [24] Intra-and inter-observer variability of point of care ultrasound measurements to evaluate hemodynamic parameters in healthy volunteers
    Blanca, Deborah
    Schwarz, Esther C.
    Olgers, Tycho Joan
    ter Avest, Ewoud
    Azizi, Nasim
    Bouma, Hjalmar R.
    Ter Maaten, Jan Cornelis
    ULTRASOUND JOURNAL, 2023, 15 (01)
  • [25] Effect of clinician's experience and expertise on the inter- and intra-observer reliability of the computed tomography-based classification systems in posterior malleolus fractures
    Cirdi, Yigit Umur
    Demirel, Mehmet
    Kayaalp, Mahmut Enes
    Ozturk, Ramazan Ilter
    Bozoglan, Muhammet
    Salvi, Andrea Giordano
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (03) : 176 - 181
  • [26] How to assess intra- and inter-observer agreement with quantitative PET using variance component analysis: a proposal for standardisation
    Gerke, Oke
    Vilstrup, Mie Holm
    Segtnan, Eivind Antonsen
    Halekoh, Ulrich
    Hoilund-Carlsen, Poul Flemming
    BMC MEDICAL IMAGING, 2016, 16
  • [27] Inter- and intra-observer reliability of contrast-enhanced magnetic resonance imaging parameters in children with suspected juvenile idiopathic arthritis of the hip (vol 48, pg 1891, 2018)
    Porter-Young, Francesca M.
    Offiah, Amaka C.
    Broadley, Penny
    Lang, Isla
    McMahon, Anne-Marie
    Howsley, Philippa
    Hawley, Daniel P.
    PEDIATRIC RADIOLOGY, 2018, 48 (13) : 1901 - 1901
  • [28] Impact of the Intra- and Inter-observer Variability in the Delineation of Parotid Glands on the Dose Calculation During Head and Neck Helical Tomotherapy
    Piotrowski, T.
    Gintowt, K.
    Jodda, A.
    Ryczkowski, A.
    Bandyk, W.
    Bak, B.
    Adamczyk, M.
    Skorska, M.
    Kazmierska, J.
    Malicki, J.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (04) : 467 - 474
  • [29] Inter- and intra-observer agreement for grading radiographs of thoracolumbar spinous processes in healthy horses during a pre-purchase examination
    Looijen, Maty G. P.
    Hanousek, Katherine
    Maree, Jacques T. M.
    Visser, Margriet C.
    Berner, Dagmar
    VETERINARY RECORD, 2022, 190 (06)
  • [30] Intra- and inter‐observer reliability of implant positioning evaluation on a CT-based three‐dimensional postoperative matching system for total knee arthroplasty
    Shotaro Watanabe
    Ryuichiro Akagi
    Yuki Shiko
    Yoshimasa Ono
    Yohei Kawasaki
    Toshihiro Ohdera
    Seiji Ohtori
    Takahisa Sasho
    BMC Musculoskeletal Disorders, 22