Objectives To evaluate the inter-observer, intra-observer and intra-individual reliability of uroflowmetry and post-void residual urine (PVR) tests in adult men. Methods Healthy volunteers aged over 40 years were enrolled. Every participant underwent two sets of uroflowmetry and PVR tests with a 2-week interval between the tests. The uroflowmetry tests were interpreted by four urologists independently. Uroflowmetry curves were classified as bell-shaped, bell-shaped with tail, obstructive, restrictive, staccato, interrupted and tower-shaped and scored from 1 (highly abnormal) to 5 (absolutely normal). The agreements between the observers, interpretations and tests within individuals were analyzed using kappa statistics and intraclass correlation coefficients. Generalizability theory with decision analysis was used to determine how many observers, tests, and interpretations were needed to obtain an acceptable reliability (> 0.80). Results Of 108 volunteers, we randomly selected the uroflowmetry results from 25 participants for the evaluation of reliability. The mean age of the studied adults was 55.3 years. The intra-individual and intra-observer reliability on uroflowmetry tests ranged from good to very good. However, the inter-observer reliability on normalcy and specific type of flow pattern were relatively lower. In generalizability theory, three observers were needed to obtain an acceptable reliability on normalcy of uroflow pattern if the patient underwent uroflowmetry tests twice with one observation. Conclusions The intra-individual and intra-observer reliability on uroflowmetry tests were good while the inter-observer reliability was relatively lower. To improve inter-observer reliability, the definition of uroflowmetry should be clarified by the International Continence Society.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 33 条
  • [1] Inter-observer and intra-observer reliability of the myopic traction maculopathy staging system
    Frisina, Rino
    Besozzi, Gianluca
    Finzi, Alessandro
    Pinackatt, Sajish Joseph
    Palmieri, Michele
    Parolini, Barbara
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (03) : 1577 - 1583
  • [2] Visual diagnosis of pectus excavatum: An inter-observer and intra-observer agreement analysis
    Daemen, Jean H. T.
    de Loos, Erik R.
    Geraedts, Tessa C. M.
    van Veer, Hans
    Van Huijstee, Pieter Jan
    Elenbaas, Ted W. O.
    Hulsewe, Karel W. E.
    Vissers, Yvonne L. J.
    JOURNAL OF PEDIATRIC SURGERY, 2022, 57 (03) : 526 - 531
  • [3] INTRA-OBSERVER AND DEVICE-DEPENDENT INTER-OBSERVER RELIABILITY OF CONTRAST-ENHANCED ULTRASOUND FOR MUSCLE PERFUSION QUANTIFICATION
    Kunz, Pierre
    Kiesl, Sophia
    Gro, Sascha
    Kauczor, Hans-Ulrich
    Schmidmaier, Gerhard
    Fischer, Christian
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (02) : 275 - 285
  • [4] Inter-observer and intra-observer reliability of mechanical axis alignment before and after total knee arthroplasty using long leg radiographs
    Bowman, Anneka
    Shunmugam, Meenalochani
    Watts, Amy R.
    Bramwell, Donald C.
    Wilson, Christopher
    Krishnan, Jeganath
    KNEE, 2016, 23 (02) : 203 - 208
  • [5] Inter- and Intra-observer Reliability of MRI for Lumbar Lateral Disc Herniation
    Kim, Seong Wan
    Yeom, Jin S.
    Park, Seong Kyu
    Chang, Bong Soon
    Lee, Dong-Ho
    Lee, Jae Hyup
    Park, Kun-Woo
    Seo, Eun Seok
    Lee, Choon-Ki
    CLINICS IN ORTHOPEDIC SURGERY, 2009, 1 (01) : 34 - 39
  • [6] Inter-observer and intra-observer agreement of cervical vertebral maturation staging: A systematic review and meta-analysis
    Hussain, Umar
    Ul Hassan, Faizan
    Kamran, Muhammad Abdullah
    Alnazeh, Abdullah A.
    Ullah, Imran
    Alam, Shamsul
    INTERNATIONAL ORTHODONTICS, 2024, 22 (03)
  • [7] Inter- and intra-observer reliability of different methods for recording temperament in beef and dairy calves
    Vogt, Anina
    Aditia, Edit Lesa
    Schlechter, Imke
    Schuetze, Susanne
    Geburt, Katrin
    Gauly, Matthias
    von Borstel, Uta Koenig
    APPLIED ANIMAL BEHAVIOUR SCIENCE, 2017, 195 : 15 - 23
  • [8] Intra- and inter-observer reliability of Cobb angle measurements in patients with adolescent idiopathic scoliosis
    F. G. Prestigiacomo
    M. H. H. M. Hulsbosch
    V. E. J. Bruls
    J. J. Nieuwenhuis
    Spine Deformity, 2022, 10 : 79 - 86
  • [9] Intra- and inter-observer reliability of Cobb angle measurements in patients with adolescent idiopathic scoliosis
    Prestigiacomo, F. G.
    Hulsbosch, M. H. H. M.
    Bruls, V. E. J.
    Nieuwenhuis, J. J.
    SPINE DEFORMITY, 2022, 10 (01) : 79 - 86
  • [10] Analysis of the Intra- and Inter-observer Reliabilities of Delbet Classification: Is Simplification Required
    Muhammet Bozoğlan
    Gökhan Cansabuncu
    Mert Kumbaraci
    Safa Bozkurt
    Ali Turgut
    Indian Journal of Orthopaedics, 2023, 57 : 1478 - 1484