Analysis of Statistical Models for Iterative Reconstruction of Extremely Low-Dose CT Data

被引:0
|
作者
Kim, Soo Mee [1 ]
Alessio, Adam M. [1 ]
Perlmutter, David S. [1 ]
Thibault, Jean-Baptiste [2 ]
De Man, Bruno
Kinahan, Paul E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98185 USA
[2] GE Healthcare Technol, Appl Sci Lab, Waukesha, WI 53188 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In order to reduce CT radiation dose, there have been numerous efforts to develop low-dose acquisition protocols as well as noise reduction methods such as data denoising and iterative reconstruction. In this study, we analyze the first and second order statistics of post-log CT data and the resulting impact on iterative image reconstruction for extremely low-dose CT acquisitions. We performed a CT simulation incorporating polychromatic forward projection and realistic levels of quantum and electronic noise. We performed N=1000 simulations of a chest phantom to analyze the impact of processing steps on the statistics of post-log data. We investigated the impact of two non-positivity correction methods, threshold and mean-preserving filter. And, we analyzed the bias and variance of different weighting terms and performed weighted least squares reconstruction with these different weights. For the simulation of an extremely low dose chest acquisition with 80 kVp and 0.5 mAs, the mean-preserving filter reduced the mean bias of post-log sinogram by roughly seven times compared to the threshold method. The WLS reconstructed images using simple weighting terms that ignored the effect of non-positive correction lead to limited improvements in image quality. Accurate weighting terms including electronic noise and the variance change from MPF provided superior images, especially in highly attenuating regions where bias reductions of similar to 17% were achieved compared to simple weighting matrices. Appropriate selection of the non-positivity correction method is essential for low flux CT data processing. The proposed method for estimating the weighting matrix with electronic noise and the effect of pre-corrections leads to some improvements in variance estimation for post-log CT data, although it has potential for further improvement.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] CT FOR EVALUATION OF UROLITHIASIS: IMAGE QUALITY OF ULTRALOW-DOSE (SUB MSV) CT WITH KNOWLEDGE-BASED ITERATIVE RECONSTRUCTION AND DIAGNOSTIC PERFORMANCE OF LOW-DOSE CT WITH STATISTICAL ITERATIVE RECONSTRUCTION
    Kim, Jin Wook
    Moon, Young Tae
    Kim, Kyung Do
    Kim, Tae-Hyoung
    Myung, Soon Chul
    Ahn, Seung Hyun
    Choi, Jae Duck
    Kim, Jung Hoon
    Kim, Min Soo
    Lee, Shin Young
    Chi, Byung Hoon
    Chang, In Ho
    JOURNAL OF UROLOGY, 2016, 195 (04): : E1079 - E1079
  • [22] Iterative algorithms for low-dose CT
    Li, X
    Madsen, MT
    Jiang, M
    Wang, G
    RADIOLOGY, 2002, 225 : 255 - 255
  • [23] Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 Patients
    Sagara, Yoshiko
    Hara, Amy K.
    Pavlicek, William
    Silva, Alvin C.
    Paden, Robert G.
    Wu, Qing
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 713 - 719
  • [24] Combining Automatic Tube Current Modulation with Adaptive Statistical Iterative Reconstruction for Low-Dose Chest CT Screening
    Chen, Jiang-Hong
    Jin, Er-Hu
    He, Wen
    Zhao, Li-Qin
    PLOS ONE, 2014, 9 (04):
  • [25] Preliminary study of dose reduction and image quality of adult pelvic low-dose CT scan with adaptive statistical iterative reconstruction
    Li, Wei
    Zhang, Cheng-Qi
    Li, Ai-Yin
    Deng, Kai
    Shi, Hao
    ACTA RADIOLOGICA, 2015, 56 (10) : 1222 - 1229
  • [26] Comparison of low-dose CT with adaptive statistical iterative reconstruction and conventional filtered back projection in whole body PET/CT
    Tang, Yongjin
    Ling, Xueying
    Xiao, Zeyu
    Shang JingJie
    Xu, Hao
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [27] Comparison of low-dose CT with adaptive statistical iterative reconstruction and conventional filtered back projection in whole body PET/CT
    Tang, Yongjin
    Ling, Xueying
    Xiao, Zeyu
    Shang JingJie
    Xu, Hao
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [28] Noise Reduction Method in Low-dose CT Data Combining Neural Networks and an Iterative Reconstruction Technique
    Choi, Dahim
    Kim, Juhee
    Chae, Seung-Hoon
    Baek, Jongduk
    Maier, Andreas
    Fahrig, Rebecca
    Park, Hyun-Seok
    Choi, Jang-Hwan
    INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [29] QUANTIFICATION OF EMPHYSEMA USING LOW-DOSE CHEST CT: EFFECT OF ITERATIVE RECONSTRUCTION
    Park, K. J.
    Cho, J. Y.
    RESPIRATORY MEDICINE, 2017, 132 : 274 - 274
  • [30] Impact of iterative reconstruction on image quality of low-dose CT of the lumbar spine
    Alshamari, Muhammed
    Geijer, Mats
    Norrman, Eva
    Liden, Mats
    Krauss, Wolfgang
    Jendeberg, Johan
    Magnuson, Anders
    Geijer, Hakan
    ACTA RADIOLOGICA, 2017, 58 (06) : 702 - 709