Analysis of Statistical Models for Iterative Reconstruction of Extremely Low-Dose CT Data

被引:0
|
作者
Kim, Soo Mee [1 ]
Alessio, Adam M. [1 ]
Perlmutter, David S. [1 ]
Thibault, Jean-Baptiste [2 ]
De Man, Bruno
Kinahan, Paul E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98185 USA
[2] GE Healthcare Technol, Appl Sci Lab, Waukesha, WI 53188 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In order to reduce CT radiation dose, there have been numerous efforts to develop low-dose acquisition protocols as well as noise reduction methods such as data denoising and iterative reconstruction. In this study, we analyze the first and second order statistics of post-log CT data and the resulting impact on iterative image reconstruction for extremely low-dose CT acquisitions. We performed a CT simulation incorporating polychromatic forward projection and realistic levels of quantum and electronic noise. We performed N=1000 simulations of a chest phantom to analyze the impact of processing steps on the statistics of post-log data. We investigated the impact of two non-positivity correction methods, threshold and mean-preserving filter. And, we analyzed the bias and variance of different weighting terms and performed weighted least squares reconstruction with these different weights. For the simulation of an extremely low dose chest acquisition with 80 kVp and 0.5 mAs, the mean-preserving filter reduced the mean bias of post-log sinogram by roughly seven times compared to the threshold method. The WLS reconstructed images using simple weighting terms that ignored the effect of non-positive correction lead to limited improvements in image quality. Accurate weighting terms including electronic noise and the variance change from MPF provided superior images, especially in highly attenuating regions where bias reductions of similar to 17% were achieved compared to simple weighting matrices. Appropriate selection of the non-positivity correction method is essential for low flux CT data processing. The proposed method for estimating the weighting matrix with electronic noise and the effect of pre-corrections leads to some improvements in variance estimation for post-log CT data, although it has potential for further improvement.
引用
收藏
页数:4
相关论文
共 50 条
  • [11] Reduction of CT Exposure for Low-Dose CT Imaging by Iterative CT Reconstruction
    Grosser, O. S.
    Czuczwara, D.
    Wissel, H.
    Laatz, K.
    Ulrich, G.
    Furth, C.
    Ruf, J.
    Amthauer, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S501 - S501
  • [12] Fast iterative adaptive reconstruction in low-dose CT imaging
    Cheng, Lin
    Chen, Yunqiang
    Fang, Tong
    Tyan, Jason
    2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 889 - +
  • [13] Investigation of iterative image reconstruction in low-dose breast CT
    Bian, Junguo
    Yang, Kai
    Boone, John M.
    Han, Xiao
    Sidky, Emil Y.
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2659 - 2685
  • [14] Iterative reconstruction of low-dose CT based on differential sparse
    Lu, Siyu
    Yang, Bo
    Xiao, Ye
    Liu, Shan
    Liu, Mingzhe
    Yin, Lirong
    Zheng, Wenfeng
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [15] SPULTRA: Low-Dose CT Image Reconstruction With Joint Statistical and Learned Image Models
    Ye, Siqi
    Ravishankar, Saiprasad
    Long, Yong
    Fessler, Jeffrey A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (03) : 729 - 741
  • [16] Quantitative Analysis of Airway Tree in Low-dose Chest CT with a New Model-based Iterative Reconstruction Algorithm: Comparison to Adaptive Statistical Iterative Reconstruction in Routine-dose CT
    Jia, Yongjun
    Ji, Xing
    He, Taiping
    Yu, Yong
    Yu, Nan
    Duan, Haifeng
    Guo, Youmin
    ACADEMIC RADIOLOGY, 2018, 25 (12) : 1526 - 1532
  • [17] The optimal protocols of low-dose CT with iterative reconstruction CT in PET/CT scan
    Yang, Bang-Hung
    Wu, Nien-Yun
    Chen, Guan-Ling
    Wu, Tung-Hsin
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [18] Low-Dose MDCT and CT Enterography of Patients With Crohn Disease: Feasibility of Adaptive Statistical Iterative Reconstruction
    Kambadakone, Avinash R.
    Chaudhary, Naueen A.
    Desai, Gaurav S.
    Nguyen, Deanna D.
    Kulkarni, Naveen M.
    Sahani, Dushyant V.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W743 - W752
  • [19] CT for evaluation of urolithiasis: image quality of ultralow-dose (Sub mSv) CT with knowledge-based iterative reconstruction and diagnostic performance of low-dose CT with statistical iterative reconstruction
    Joonho Hur
    Sung Bin Park
    Jong Beum Lee
    Hyun Jeong Park
    In Ho Chang
    Jong Kyou Kwon
    Yang Soo Kim
    Abdominal Imaging, 2015, 40 : 2432 - 2440
  • [20] CT for evaluation of urolithiasis: image quality of ultralow-dose (Sub mSv) CT with knowledge-based iterative reconstruction and diagnostic performance of low-dose CT with statistical iterative reconstruction
    Hur, Joonho
    Park, Sung Bin
    Lee, Jong Beum
    Park, Hyun Jeong
    Chang, In Ho
    Kwon, Jong Kyou
    Kim, Yang Soo
    ABDOMINAL IMAGING, 2015, 40 (07): : 2432 - 2440