Detection of viruses directly from the fresh leaves of a Phalaenopsis orchid using a microfluidic system

被引:32
|
作者
Chang, Wen-Hsin [1 ]
Yang, Sung-Yi [1 ]
Lin, Chih-Lin [1 ]
Wang, Chih-Hung [1 ]
Li, Ping-Chen [4 ]
Chen, Tzong-Yueh [5 ]
Jan, Fuh-Jyh [4 ]
Lee, Gwo-Bin [2 ,3 ]
机构
[1] Natl Tsing Hua Univ, Dept Power Mech Engn, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Inst Biomed Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst Nanoengn & Microsyst, Hsinchu, Taiwan
[4] Natl Chung Hsing Univ, Dept Plant Pathol, Taichung 400, Taiwan
[5] Natl Cheng Kung Univ, Inst Biotechnol, Tainan, Taiwan
关键词
Microfluidics; Phalaenopsis orchid; Pathogen detection; Loop-mediated-isothermal-amplification; MEDIATED-ISOTHERMAL-AMPLIFICATION; ODONTOGLOSSUM RINGSPOT TOBAMOVIRUS; CYMBIDIUM MOSAIC POTEXVIRUS; QUANTITATIVE DETECTION; DIAGNOSTIC DEVICE; RAPID DETECTION; DNA; POINT; GENE; CARE;
D O I
10.1016/j.nano.2013.05.016
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Early detection of pathogens is crucial for the effective surveillance of diseases. Many efforts have been made to explore methods which can detect these pathogens within a short period of time without requiring a tedious protocol. However, these developed methods have disadvantages such as they are relatively time-consuming or require specialized laboratory facilities. In this work, we have developed an integrated microfluidic system for rapid and automatic detection of viruses by direct analysis from fresh Phalaenopsis orchid leaves. The entire protocol, including ribonucleic acid (RNA) purification, reverse transcription loop-mediated-isothermal-amplification (RT-LAMP) and optical detection by measuring changes in turbidity was performed on a single chip. This is the first time that an integrated microfluidic system for the detection of viruses infecting the Phalaenopsis orchid has been demonstrated. The sensitivity of the developed system was also explored in this study to validate its performance. From the Clinical Editor: In this study, the authors report the development of an integrated microfluidic system for rapid and automatic detection of viruses by direct analysis of fresh Phalaenopsis orchid leaves, performing the 3-step protocol using a single chip. Similar methods may find clinical application for fast and accurate detection of viral infections. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1274 / 1282
页数:9
相关论文
共 50 条
  • [41] An integrated microfluidic system for cholangiocarcinoma diagnosis from bile by using specific affinity probes
    Lu, Tsung-Han
    Chiang, Nai-Jung
    Tsai, Yi-Cheng
    Gopinathan, Priya
    Huang, Chien-Jui
    Chang, Jui-Lin
    Tu, Hsiu-Chi
    Shan, Yan-Shen
    Hung, Shang-Cheng
    Lee, Gwo-Bin
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 373
  • [42] Real-time, continuous detection of maltose using bioluminescence resonance energy transfer (BRET) on a microfluidic system
    Le, Nam Cao Hoai
    Gel, Murat
    Zhu, Yonggang
    Dacres, Helen
    Anderson, Alisha
    Trowell, Stephen C.
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 177 - 181
  • [43] A microfluidic-based system using reverse transcription polymerase chain reactions for rapid detection of aquaculture diseases
    Lien, Kang-Yi
    Lee, Szu-Hsien
    Tsai, Tieh-Jung
    Chen, Tzong-Yueh
    Lee, Gwo-Bin
    MICROFLUIDICS AND NANOFLUIDICS, 2009, 7 (06) : 795 - 806
  • [44] A microfluidic-based system using reverse transcription polymerase chain reactions for rapid detection of aquaculture diseases
    Kang-Yi Lien
    Szu-Hsien Lee
    Tieh-Jung Tsai
    Tzong-Yueh Chen
    Gwo-Bin Lee
    Microfluidics and Nanofluidics, 2009, 7
  • [45] Rapid detection of pathogenic fungi from coastal population with respiratory infections using microfluidic chip technology
    Yao, Qingmei
    He, Yuan
    Deng, Liehua
    Chen, Dafeng
    Zhang, Yuanli
    Luo, Hui
    Lei, Wei
    BMC INFECTIOUS DISEASES, 2024, 24 (01)
  • [46] Rapid detection of pathogenic fungi from coastal population with respiratory infections using microfluidic chip technology
    Qingmei Yao
    Yuan He
    Liehua Deng
    Dafeng Chen
    Yuanli Zhang
    Hui Luo
    Wei Lei
    BMC Infectious Diseases, 24
  • [47] Point-of-Care and Label-Free Detection of Porcine Reproductive and Respiratory Syndrome and Swine Influenza Viruses Using a Microfluidic Device with Photonic Integrated Circuits
    Manessis, Georgios
    Frant, Maciej
    Wozniakowski, Grzegorz
    Nannucci, Lapo
    Benedetti, Martina
    Denes, Lilla
    Gyula, Balka
    Gelasakis, Athanasios, I
    Squires, Clare
    Recuero, Sara
    Sanchez, Carlos
    Griol, Amadeu
    Giusti, Alessandro
    Bossis, Ioannis
    VIRUSES-BASEL, 2022, 14 (05):
  • [48] Detection of OXA-370 directly from rectal swabs and blood culture vials using an immunochromatographic assay
    Nodari, Carolina Silva
    Gales, Ana Cristina
    Barth, Afonso Luis
    Magagnin, Cibele Massotti
    Zavascki, Alexandre Prehn
    Carvalhaes, Cecilia Godoy
    JOURNAL OF MICROBIOLOGICAL METHODS, 2017, 139 : 92 - 94
  • [49] A magnetic bead-based assay for the rapid detection of methicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loop-mediated isothermal amplification
    Wang, Chih-Hung
    Lien, Kang-Yi
    Wu, Jiunn-Jong
    Lee, Gwo-Bin
    LAB ON A CHIP, 2011, 11 (08) : 1521 - 1531
  • [50] 3D printed electrochemical sensor and microfluidic system for the detection of L-tryptophan using degradable material
    Zhan, Tao
    Zhao, Bo
    Zhou, Zhen-Fan
    Chen, Zhencheng
    Zhang, Min
    Han, Guo-Cheng
    Feng, Xiao-Zhen
    Kraatz, Heinz-Bernhard
    FOOD CHEMISTRY, 2025, 475