Detection of viruses directly from the fresh leaves of a Phalaenopsis orchid using a microfluidic system

被引:32
|
作者
Chang, Wen-Hsin [1 ]
Yang, Sung-Yi [1 ]
Lin, Chih-Lin [1 ]
Wang, Chih-Hung [1 ]
Li, Ping-Chen [4 ]
Chen, Tzong-Yueh [5 ]
Jan, Fuh-Jyh [4 ]
Lee, Gwo-Bin [2 ,3 ]
机构
[1] Natl Tsing Hua Univ, Dept Power Mech Engn, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Inst Biomed Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst Nanoengn & Microsyst, Hsinchu, Taiwan
[4] Natl Chung Hsing Univ, Dept Plant Pathol, Taichung 400, Taiwan
[5] Natl Cheng Kung Univ, Inst Biotechnol, Tainan, Taiwan
关键词
Microfluidics; Phalaenopsis orchid; Pathogen detection; Loop-mediated-isothermal-amplification; MEDIATED-ISOTHERMAL-AMPLIFICATION; ODONTOGLOSSUM RINGSPOT TOBAMOVIRUS; CYMBIDIUM MOSAIC POTEXVIRUS; QUANTITATIVE DETECTION; DIAGNOSTIC DEVICE; RAPID DETECTION; DNA; POINT; GENE; CARE;
D O I
10.1016/j.nano.2013.05.016
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Early detection of pathogens is crucial for the effective surveillance of diseases. Many efforts have been made to explore methods which can detect these pathogens within a short period of time without requiring a tedious protocol. However, these developed methods have disadvantages such as they are relatively time-consuming or require specialized laboratory facilities. In this work, we have developed an integrated microfluidic system for rapid and automatic detection of viruses by direct analysis from fresh Phalaenopsis orchid leaves. The entire protocol, including ribonucleic acid (RNA) purification, reverse transcription loop-mediated-isothermal-amplification (RT-LAMP) and optical detection by measuring changes in turbidity was performed on a single chip. This is the first time that an integrated microfluidic system for the detection of viruses infecting the Phalaenopsis orchid has been demonstrated. The sensitivity of the developed system was also explored in this study to validate its performance. From the Clinical Editor: In this study, the authors report the development of an integrated microfluidic system for rapid and automatic detection of viruses by direct analysis of fresh Phalaenopsis orchid leaves, performing the 3-step protocol using a single chip. Similar methods may find clinical application for fast and accurate detection of viral infections. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1274 / 1282
页数:9
相关论文
共 50 条
  • [31] Ultrafast PCR Detection of COVID-19 by Using a Microfluidic Chip-Based System
    Chen, Xiaojing
    Liu, Yiteng
    Zhan, Xuan
    Gao, Yibo
    Sun, Zhongyi
    Wen, Weijia
    Zheng, Weidong
    BIOENGINEERING-BASEL, 2022, 9 (10):
  • [32] A microfluidic immunomagnetic bead-based system for the rapid detection of influenza infections: from purified virus particles to clinical specimens
    Hung, Lien-Yu
    Huang, Tze-Bin
    Tsai, Yi-Che
    Yeh, Chen-Sheng
    Lei, Huan-Yao
    Lee, Gwo-Bin
    BIOMEDICAL MICRODEVICES, 2013, 15 (03) : 539 - 551
  • [33] Identification of Viruses Infecting Phalaenopsis Orchids Using Nanopore Sequencing and Development of an RT-RPA-CRISPR/Cas12a for Rapid Visual Detection of Nerine Latent Virus
    Lee, Hyo-Jeong
    Kim, Hae-Jun
    Cho, In-Sook
    Jeong, Rae-Dong
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (05)
  • [34] Development of a real time RT-PCR with SYBR Green dye for the detection of several viruses from the bulbs and leaves of lily
    Lim, J. -H.
    Bae, E. H.
    Park, S. -H.
    Lee, K. J.
    Kim, S. R. Mi
    Kwon, E. Y.
    Lee, Y. J.
    Jung, Y. -T.
    ACTA VIROLOGICA, 2010, 54 (04) : 319 - 321
  • [35] Pattern recognition system for rapid detection of gases using microfluidic olfaction detector: A case study using methane and ethane
    Aly, Mohamed Tarek
    Tasnim, Nishat
    Najjaran, Homayoun
    Fardindoost, Somayeh
    Hoorfar, Mina
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 403
  • [36] Microfluidic System for Detection of Viral RNA in Blood Using a Barcode Fluorescence Reporter and a Photocleavable Capture Probe
    Du, Ke
    Park, Myeongkee
    Griffiths, Anthony
    Carrion, Ricardo
    Patterson, Jean
    Schmidt, Holger
    Mathies, Richard
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12433 - 12440
  • [37] A Reusable Capillary Flow-Driven Microfluidic System for Abscisic Acid Detection Using a Competitive Immunoassay
    Domingues, Cristiana
    Rodrigues, Marta S. C.
    Condelipes, Pedro G. M.
    Fortes, Ana Margarida
    Chu, Virginia
    Conde, Joao Pedro
    SENSORS, 2025, 25 (02)
  • [38] Magnetic nanoparticle-based immunoassay for rapid detection of influenza infections by using an integrated microfluidic system
    Hung, Lien-Yu
    Chang, Jui-Cheng
    Tsai, Yi-Che
    Huang, Chih-Chia
    Chang, Chih-Peng
    Yeh, Chen-Sheng
    Lee, Gwo-Bin
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2014, 10 (04) : 819 - 829
  • [39] Rapid, enhanced detection of Salmonella Typhimurium on fresh spinach leaves using micron-scale, phage-coated magnetoelastic biosensors
    Horikawa, Shin
    Vaglenov, Kiril A.
    Gerken, Dana M.
    Chai, Yating
    Park, Mi-Kyung
    Li, Suiqiong
    Petrenko, Valery A.
    Chin, Bryan A.
    SENSING FOR AGRICULTURE AND FOOD QUALITY AND SAFETY IV, 2012, 8369
  • [40] Highly Sensitive and Specific Detection of Influenza A Viruses Using Bimolecular Fluorescence Complementation (BiFC) Reporter System
    Lee, Ui Jin
    Oh, Yunkwang
    Kwon, Oh Seok
    Shin, Yong-Beom
    Kim, Moonil
    BIOSENSORS-BASEL, 2023, 13 (08):